3.2 Fair Housing, ADA & Michigan Barrier-Free Design

Key Takeaways

  • FHA design and construction requirements apply to covered units designed and built for first occupancy after March 13, 1991. In a qualifying building with at least four units, coverage usually includes every unit if a building elevator serves upper residential floors, or ground-floor units if there is no elevator.

  • The seven FHA design requirements cover the accessible building entrance and route, public and common areas, usable doors, an accessible route through covered units, reachable controls, reinforcement for future grab bars, and usable kitchens and bathrooms.

  • ADA Title I generally covers private employers with 15 or more employees. Title II covers state and local government activities. Title III applies to public accommodations and commercial facilities as specified. Use the March 15, 2012 transition for the 2010 Standards and the separate 20% path-of-travel rule for qualifying alterations.

  • Under MCL 125.1352(2), measure affected area against floor area usable by the public or employees. Below 50%, include the affected area and continuous route to and from the nearest entrance, including the entrance. At 50% or more, the entire covered facility is subject to the requirement.

  • Ordinary privately owned one- and two-family dwellings are excluded from the housing scope of 1966 PA 1. Display of a noncompliant symbol of access on a facility used by the public carries a $250 fine (MCL 125.1352(6)).

Last updated: November 2026

Quick Answer: A project can involve federal Fair Housing Act (FHA) dwelling design, distinct ADA obligations and Michigan barrier-free code review. Start with the building's occupants, use and relevant project dates.

The Fair Housing Act's design and construction requirements

The FHA protects against housing discrimination based on race, color, religion, sex, national origin, familial status and disability. 42 USC 3604(f)(3)(C), (7) and 24 CFR 100.205 govern covered multifamily dwellings for first occupancy after March 13, 1991. A dwelling is treated as designed and built for first occupancy by that date if it was occupied by then or if the last building permit or renewal was issued by June 15, 1990. First occupancy refers to the building's first use for any purpose. Converting a previously used building to housing does not by itself make it new for this rule.

Count the dwelling units in the building and determine which floors its elevator serves.

  • Four or more units with a building elevator serving the upper residential floors: all units are generally covered. HUD and DOJ distinguish elevators that connect only parking and ground-floor units, and elevators contained within individual units.
  • Four or more units with no elevator: ground-floor units are covered. A ground floor has a building entrance on an accessible route. A building can have multiple ground floors. Covered dwellings need access to the required public and common use areas.
  • Townhouses: a multistory townhouse in a nonelevator building is ordinarily outside the unit-specific design requirements even if its entrance is on the ground floor. A unit served by a building elevator or with a unit-specific elevator requires separate analysis. A detached one-family house, duplex or triplex falls below the four-unit building threshold.
  • Site impracticality: the designer or builder bears the burden of showing that terrain or unusual site characteristics make an accessible entrance impractical.

The seven design requirements

  1. At least one accessible building entrance on an accessible route.
  2. Public and common use areas (parking, mailboxes, laundry, pool) readily accessible to and usable by persons with disabilities.
  3. Usable doors — all doors allowing passage into and within premises must be wide enough for wheelchair passage.
  4. An accessible route into and through the covered dwelling unit.
  5. Light switches, electrical outlets, thermostats, and other environmental controls in accessible locations.
  6. Reinforcements in bathroom walls to allow later installation of grab bars.
  7. Usable kitchens and bathrooms so an individual in a wheelchair can maneuver about and use the space.

Example: A 24-unit apartment building has single-level units and a common passenger elevator to all residential floors. Its permit and first occupancy are in 2020. The FHA design requirements apply to every unit and to the relevant public and common use areas.

ADA Titles I and II

Title I generally covers private employers with at least 15 employees on each working day in 20 or more calendar weeks in the current or preceding year. A covered employer must reasonably accommodate a qualified individual unless undue hardship applies. Before a conditional offer, ask whether an applicant can perform job-related functions and observe the restriction on disability inquiries and medical examinations (42 USC 12111–12112). Title II covers state and local government services, programs and activities. A contractor designing a township public counter should check the Title II facility rules in 28 CFR 35.151.

ADA Title III: public accommodations and commercial facilities

Title III covers a sales showroom open to the public as a place of public accommodation. A commercial facility may also be subject to construction and alteration provisions (28 CFR 36.401–36.406). For permitted new construction, the original trigger uses first occupancy after January 26, 1993 and the controlling permit application or extension date after January 26, 1992. A separate date determines the technical standards. Covered work uses the 2010 ADA Standards if the last permit or extension application was certified complete on or after March 15, 2012, or received on or after that date when applications are not certified complete. Without a permit requirement, use the date physical work began. Alterations must make the altered portions accessible to the maximum extent feasible.

An alteration affecting a primary function area, such as a showroom sales floor, generally triggers accessibility work on the path of travel and serving facilities such as restrooms. Path-of-travel costs are disproportionate if they exceed 20% of the primary function alteration cost. For a $100,000 sales-floor alteration, that gives $20,000 for the route-cost test. If full route work would exceed that amount, prioritize achievable access improvements within it under 28 CFR 36.403. Evaluate accessibility for the altered area independently.

The Michigan Persons with Disabilities Civil Rights Act

Michigan's Persons with Disabilities Civil Rights Act, 1976 PA 220, covers employers with one or more employees and includes specified government contractors and subcontractors and their agents (MCL 37.1201). Its employment provisions address discrimination based on disability or genetic information unrelated to job performance and the use of adaptive aids that enable a worker to meet job requirements (MCL 37.1202). The Act provides for accommodation unless undue hardship applies, subject to Article 2's specific rules (MCL 37.1102 and 37.1210). MDCR's administrative complaint period is 180 days from the alleged discriminatory act.

Michigan barrier-free design: statutes, rules, and triggers

Michigan's 1966 PA 1 requires barrier-free design under the state construction code. For work under the 2021 Michigan Building Code, effective April 9, 2025, Chapter 11 scopes what must be accessible. Section 1102.1 as amended by R 408.30427 references 1966 PA 1, the building code and ICC A117.1-2017, except sections 611 and 707. The 2015 Michigan Residential Code remains the separate Part 5 code for projects within its scope. Check its specific cross-references where relevant. Requests for barrier-free exceptions proceed under 1966 PA 1 (R 408.30414).

  • A public facility or facility used by the public whose construction contract (or first contract for a portion) was made after July 2, 1974 must meet the barrier-free requirements of the state construction code.
  • For an existing covered facility, a change in use group or occupancy load, or an alteration beyond ordinary maintenance, after July 20, 1975 triggers a floor-area test. Below 50 percent of the space usable by the public or employees, cover the affected area and the continuous unobstructed route between it and the nearest entrance, including that entrance. At 50 percent or more, the entire facility must comply.
  • For a facility used by the public, the proper authority must approve before permit or certificate of occupancy issuance. Government-owned or occupied public facilities have the separate pre-award or pre-lease approval rule in MCL 125.1352(4). A person who displays a noncompliant symbol of access at a facility used by the public is subject to a $250 fine.

The housing scope in MCL 125.1351(d) and (g) excludes a privately owned one- or two-family dwelling. The public use of a space can matter independently. For example, assess a public sales office separately from the dwelling under the Michigan code and Title III.

Applying the Tests to One Project

On a showroom remodel, measure the affected floor area for Michigan's test and the cost of altering the primary function area for Title III's route-cost test. Consult the applicable technical provisions for ramp geometry and door clearances.

Test Your Knowledge

A 2020 building has 24 single-level apartments, a building elevator serving every residential floor and an entrance on an accessible route. What must meet the applicable FHA design requirements?

A

Only the ground-floor units

B

All 24 units and the public and common use areas

C

Only units that will be occupied by persons with disabilities

D

Only the units on floors served by the elevator lobby entrance

Test Your Knowledge

A showroom sales-floor alteration triggers Title III's path-of-travel rule. Above what percentage of the sales-floor alteration cost are the associated path-of-travel costs disproportionate?

A

10 percent

B

25 percent

C

There is no limit; full path-of-travel accessibility is always required regardless of cost

D

20 percent

Test Your Knowledge

In 2026, a Michigan facility used by the public undergoes an alteration beyond ordinary maintenance affecting 30% of the floor area usable by the public or employees. What is the scope under MCL 125.1352(2)?

A

The affected area and the continuous unobstructed route to and from it, including the nearest entrance

B

The entire facility, regardless of the size of the alteration

C

Only the main entrance and one accessible restroom

D

Nothing, unless the alteration exceeds 75 percent of the floor area

Sections you finish are checked off in the contents.