40.1 Stair Construction & Code Geometry
Key Takeaways
Michigan Rule 519 supplies the ordinary stair dimensions of 8¼ inches maximum rise and 9 inches minimum tread. Check the ⅜-inch spread limits within each flight separately.
Check 36 inches clear above rail height, 31½ inches at rail height with one rail or 27 inches with two, and 6 feet 8 inches of headroom. Straight stair landings generally need 36 inches of depth and at least the width of the flight served.
For an ordinary flight with four or more risers, provide a continuous graspable handrail on at least one side. Measure the usual 34- to 38-inch height vertically from the nosing line.
The guard trigger is a drop greater than 30 inches at any point within 36 inches horizontally of the open edge. Apply the separate guard height and sphere checks for level areas, stair sides and stair triangles.
For the fewest equal risers at or below a 7½-inch design target, round the total rise divided by 7½ up to a whole number. At 108 inches the result is 15 risers of 7.2 inches. Fourteen intermediate 10-inch treads give 140 inches of run.
Quick Answer: For an ordinary stair governed by the 2015 Michigan Residential Code, use an 8¼-inch maximum riser and a 9-inch minimum tread. Check uniformity within each flight, then verify clearances, landings, rails and guards separately.
Michigan Rule 519 supplies the rise and tread dimensions. LARA’s 2015 code correction identifies the Michigan text printed at R311.7.4.1 and R311.7.4.2 as the provisions to apply in place of the corresponding model geometry at R311.7.5.1 and R311.7.5.2. LARA preserves the exceptions in R311.7.5.1. Use the special provisions where a stair is a spiral or another configuration expressly addressed by the code.
The vocabulary an inspector uses
- Rise (riser height). The vertical distance from the leading edge of one tread to the leading edge of the next, or from the finished floor or landing up to the first tread. Use the elevations of the leading edges and the finished landing or floor at each end. Under R311.7.5, carpets, rugs and runners are excluded from the dimensioned surfaces.
- Run (tread depth). The horizontal distance between the vertical planes of the foremost projection of adjacent treads, measured at a right angle to the tread leading edge.
- Nosing. The part of the tread that projects past the face of the riser below it.
- Stringer. The sloped structural member that carries the treads. A cut stringer has the step profile sawn into it; a closed stringer carries treads on cleats or ledger strips.
- Landing. The level platform at the top or bottom of a flight, or between flights.
- Headroom. The clear vertical distance from the sloped plane that touches the tread nosings up to the ceiling, soffit or framing above.
- Handrail. The graspable rail that gives a hand something to hold.
- Guard. The barrier that keeps an occupant from falling off an open side.
The Michigan dimensions
| Element | 2015 MRC requirement | Section |
|---|---|---|
| Maximum riser height | 8-1/4 inches | R311.7.4.1 |
| Minimum tread depth | 9 inches | R311.7.4.2 |
| Maximum variation within a flight, riser or tread | 3/8 inch | R311.7.4.1, R311.7.4.2 |
| Minimum clear width | 36 inches above handrail height | R311.7.1 |
| Minimum headroom | 6 feet 8 inches | R311.7.2 |
| Maximum vertical rise per flight | 147 inches | R311.7.3 |
| Landing dimension in the direction of travel | 36 inches minimum for a straight run | R311.7.6 |
| Maximum walking surface slope | 1 unit vertical in 48 units horizontal | R311.7.7 |
| Winder tread at the 12 inch walkline | 10 inches minimum; 6 inches minimum at any point | R311.7.4.2 |
| Nosing projection with solid risers | 3/4 inch to 1-1/4 inches | R311.7.5.3 |
The unamended 2015 model IRC uses 7¾ inches maximum and 10 inches minimum for ordinary risers and treads. Use the Michigan values for the Michigan residential setting. On a winder, identify the 12-inch walkline on the narrow side before checking the 10-inch minimum there and the 6-inch minimum at any point.
Under R311.7.5.3, a solid-riser stair generally needs a nosing projection from ¾ to 1¼ inches. The projection may be omitted when the tread depth is at least 11 inches. The leading radius is at most 9/16 inch and beveling is limited to ½ inch. Check the ⅜-inch maximum difference in projection between stories, including the nosings at floors and landings. Check openings between treads separately on an open-riser stair. For an open-riser gap more than 30 inches vertically above the floor or grade, check that a 4-inch sphere cannot pass. Stair-side guards have their own sphere tests, including a separate one for the triangular opening.
Uniformity is a separate test
The 3/8 inch limit is not a tolerance on the maximum and minimum; it is a third, independent test applied within each flight. Four risers that measure 8-1/8, 8, 8-1/4 and 7-3/4 inches are each legal against the 8-1/4 inch ceiling, yet the spread from 7-3/4 to 8-1/4 is 1/2 inch, so the flight fails. The same test applies to tread depth and, at the walkline, to winder treads.
Check the finished elevations and intended tread thickness before you mark the stringer. If a floor finish will be added, account for its actual thickness at that landing and recheck the first and last risers. The adjustment depends on how the stringer bears and how treads and finishes are installed.
Width, headroom and landings
Measure 36 inches clear above the permitted handrail height and below the required headroom. A handrail may project up to 4½ inches per side. At and below rail height, including treads and landings, the minimum clear width is 31½ inches with one railing and 27 inches when there are two. Check both height zones at corners and other constrictions.
Measure 6 feet 8 inches of headroom vertically from the stair nosing line or from the landing surface, as applicable. Check the floor header and soffit positions. R311.7.2 contains a limited side-of-flight floor-opening projection exception and a separate rule for spirals.
R311.7.6 generally places a floor or landing at both ends of the stairway. Match or exceed the width of the flight served. A straight run requires 36 inches of landing depth in the direction of travel. Irregular landings have separate geometry checks. At the top of an interior flight, including one in an enclosed garage, the landing can be omitted if a door does not swing over the stairs. The stair tread and landing slope is limited to 1:48 under R311.7.7.
Exterior door landings also need an R311.3 check. The general rule provides a landing on each side at least as wide as the door and at least 36 inches deep, with limited exceptions. The permitted exterior landing slope is up to ¼ inch per foot. At the required egress door, the floor or landing is generally no more than 1½ inches below the threshold, with a limited exterior exception up to 7¾ inches if the door does not swing over that surface. At another exterior door, the no-top-landing exception is limited to a stairway with no more than two exterior risers and a door that does not swing over it. For exterior stairs and landings use positive attachment for vertical and lateral forces or a self-supporting design under R311.5.1.
Laying out a stringer
Measure total rise from finished surface to finished surface. If the design chooses a 7½-inch maximum target for a straight flight, divide total rise by 7½ and round up to find the smallest riser count that meets that design target. Divide total rise by the count for the exact rise per step. Where the upper floor is the final walking surface and no separate level tread is added, subtract one to find the number of intermediate treads. Multiply by the selected tread depth to find the horizontal run.
| Total rise | Divide by 7½ | Riser count | Rise per step | Intermediate treads | Run at 10 inches |
|---|---|---|---|---|---|
| 96 inches | 12.8 | 13 | About 7.38 inches | 12 | 120 inches |
| 108 inches | 14.4 | 15 | 7.2 inches | 14 | 140 inches |
| 120 inches | 16.0 | 16 | 7.5 inches | 15 | 150 inches |
| 147 inches | 19.6 | 20 | 7.35 inches | 19 | 190 inches |
For the 108-inch case, carry 7.2 inches into the layout and check every leading edge, headroom and both landings against the plan. The 140-inch run goes from the first tread nosing to the upper floor edge. Across it there are 14 rises, or 100.8 inches vertically along that reference line. The inclined line between those noses is about 172.5 inches. Use the actual plumb and seat cuts and bearings to determine the blank length.
The 147-inch rise limit is separate from individual rise. At 8⅛ inches each, 18 risers reach 146¼ inches. At 8¼ inches each, 18 reach 148½ inches, above the single-flight limit. Check the layout against both limits and add a landing where the total rise cannot be served by one flight.
Handrails and guards
A handrail is required on at least one side of each continuous flight with four or more risers, mounted 34 to 38 inches above the sloped plane adjoining the nosings. It must run continuously from directly above the top riser to directly above the lowest riser, return to the wall or end in a newel post or safety terminal, and stand at least 1½ inches off a wall. R311.7.8.1 and R311.7.8.2 provide limited allowances for transitions, fittings and newel posts. Provide Type I, Type II or the equivalent graspability permitted by R311.7.8.3. A round Type I rail has a 1¼- to 2-inch outside diameter. A noncircular Type I rail has a 4- to 6¼-inch perimeter and at most a 2¼-inch cross-section dimension. Type II requires finger recesses on both sides. An unshaped nominal 2x4 with actual dimensions of 1½ by 3½ inches has a 10-inch perimeter and lacks those recesses.
Guards are required on open-sided walking surfaces, including stairs, ramps and landings, that are more than 30 inches above the floor or grade below at any point within 36 inches horizontally of the open edge. Guards are at least 36 inches high on level surfaces and at least 34 inches on the open sides of stairs, measured from the line connecting the tread leading edges; where the top of a stair guard also serves as the handrail it must be 34 to 38 inches. Openings may not pass a 4 inch sphere; the triangular opening formed by the tread, riser and bottom rail may not pass a 6 inch sphere; and other openings on the open sides of stairs may not pass a 4-3/8 inch sphere. Table R301.5 calls for a single 200-pound concentrated load applied in any direction along the top of a guard or handrail. Guard infill has a separate 50-pound horizontal load over one square foot, assessed independently.
What the inspector checks
- The bottom riser against the finished floor, and the spread against 3/8 inch.
- Clear width at the handrail and at any projecting corner.
- Headroom under the floor opening, not only at mid-flight.
- Handrail height, continuity, returns and wall clearance.
- Guard post attachment and the load path through the supporting framing. Verify the approved fastener and blocking detail.
- Sphere tests at balusters, the stair triangle and the open side of the flight.
- Landing size and slope, interior lighting under R303.7, and exterior lighting under R303.8. For an exterior stair from grade to a basement, check the light at the bottom landing.
Under the 2015 Michigan Residential Code, what are the maximum riser height and minimum tread depth for a main stairway?
8-1/4 inches maximum riser; 9 inches minimum tread
7-3/4 inches maximum riser; 10 inches minimum tread
8 inches maximum riser; 9-1/2 inches minimum tread
8-1/2 inches maximum riser; 8-1/2 inches minimum tread
A single straight flight climbs 108 inches between finished floors. The designer wants the fewest equal risers with none higher than 7½ inches. The upper floor is the final surface and the intermediate treads are 10 inches deep. Which layout meets those assumptions?
14 risers at about 7.71 inches with 13 treads, for a 130-inch run
15 risers at 7.2 inches with 14 treads, for a 140-inch run
15 risers at 7.2 inches with 15 treads, for a 150-inch run
16 risers at 6.75 inches with 15 treads, for a 150-inch run
For an ordinary residential stair flight, when does R311.7.8 require a handrail and what is its usual mounting height?
30 to 36 inches above the tread nosings, on any stairway with two or more risers
36 to 42 inches above the tread nosings, on any stairway with five or more risers
34 to 38 inches above the sloped plane adjoining the tread nosings, on flights with four or more risers
34 to 38 inches above the finished floor at the top landing only, on flights with six or more risers
Sections you finish are checked off in the contents.