44.2 Brick Construction

Key Takeaways

  • Michigan lists severe weathering. For solid facing brick exposed to wet freeze-thaw, use the contract and ASTM C216-13 acceptance criteria for the high-resistance grade, SW. The other C216-13 grade is MW.

  • ASTM C216 covers solid facing brick and C652 covers hollow clay or shale brick. C216 Types FBS, FBX and FBA describe dimensional and appearance requirements.

  • With the stated 7-5/8 by 2-1/4-inch brick face and exact 3/8-inch joints, the repeats are 8 by 2-5/8 inches and the count is about 6.86 brick per square foot.

  • Half-unit running bond is a common veneer layout. For aligned joints in prescriptive structural masonry, check the stack-bond reinforcement and spacing under R606.3.7.2.

  • R1001.5 allows C27 or C1261 firebrick with C199 medium-duty refractory mortar. Check the R1001.10 hearth extension against the opening area and R1001.11 clearance conditions.

Last updated: November 2026

What Kind of Brick, and Why It Matters

Select clay brick by its use, exposure and the project specification. The product name or finish on a sample does not establish its durability or dimensional tolerances.

Solid versus hollow. C216 covers solid facing brick. A unit can have cores and still be classified as solid if its net area is at least 75 percent of gross area in every plane parallel to the loadbearing surface (R202). ASTM C652 covers hollow clay or shale brick. Match the specified unit geometry and properties to the masonry assembly.

Facing versus building brick. Specify C216 where solid facing brick is wanted for its appearance, dimensional properties and durability. C62 covers solid building brick, often used for backup or other work where appearance is secondary. R606.2.2 lists both products and C652 for hollow brick. Clay thin veneer brick has a separate specification, C1088.

Types describe dimensional and appearance requirements. C216 FBX is for higher dimensional precision and less permissible variation. FBS is the general-use facing-brick type. FBA allows selected variations in size or texture for architectural effects. Use the type and exposure grade together in the specification.

Grades describe weathering. ASTM C216-13 has Grade SW for high resistance to damage from cyclic freezing and Grade MW where moderate resistance is acceptable. Michigan lists severe weathering in Table R301.2(1). Specify the grade for the actual exposure and check the applicable unit standard and required acceptance tests. Use SW for solid facing brick exposed to repeated freezing while wet.

Efflorescence appears when water brings soluble salts to the surface and evaporates. ASTM C67 provides the test for rating the brick as effloresced or not effloresced. A bloom in the field can involve salts from the units, mortar or other sources. Check recurring deposits for a moisture path such as missing flashing or a bridged cavity.

Pavers have separate specifications. C902 covers pedestrian and light-traffic paving brick and classifies weathering exposure and abrasion. C1272 covers heavy vehicular paving brick. Match the product to the actual load and exposure, including the severe-weathering paver class for the illustrated wet freeze-thaw exposure. The setting-bed system is specified separately.

Firebox brick is a refractory product. C1261 covers firebox brick for residential fireplaces. In the 2015 MRC the masonry firebox lining provisions also allow C27 firebrick when used with the required refractory mortar.

Brick typeSpecificationTypical useNotes
Facing brick, solidASTM C216Exterior veneer, interior face wallsGrades SW and MW under C216-13. Types FBX, FBS and FBA
Hollow brickASTM C652Hollow clay or shale brick for applicable masonry assembliesCheck net area, shells, exposure grade and design
Building (common) brickASTM C62Backup wythes and other general masonryCheck the specified product and exposure
Paving brickASTM C902 or C1272 by trafficWalks, patios and vehicular pavementSelect class for exposure and the assembly for loading and drainage
Firebox brickASTM C27 or C1261 under R1001.5Residential firebox liningMedium-duty refractory mortar complying with ASTM C199

Modular Dimensions, Coursing and Brick Count

Specified dimensions are the dimensions ordered for the units. Actual dimensions are measured on delivered brick and can vary within the specified tolerance. Layout dimensions include the intended mortar joints in the directions where the units repeat. Confirm the manufacturer's dimensions, then use the intended bed- and head-joint thicknesses in separate vertical and horizontal calculations.

For the example, use modular brick specified at 7-5/8 inches long, 2-1/4 inches high and 3-5/8 inches wide. At an exact 3/8-inch head and bed joint the repeat is 8 inches horizontally and 2-5/8 inches vertically. Three repeats total 7-7/8 inches. A drawings-based layout at three courses per 8 inches instead has a 2-2/3-inch average repeat. That would require about a 5/12-inch average bed joint for these units. Check the allowable joint tolerance, actual units, major datums and opening dimensions before using that module. The takeoff here uses exact 3/8-inch joints throughout.

Example brick sizeSpecified length × height (in.)Length × height with exact 3/8-in. joints (in.)Brick per square foot
Modular7-5/8 × 2-1/48 × 2-5/86.86
Standard example8 × 2-1/48-3/8 × 2-5/86.55
Queen example7-5/8 × 2-3/48 × 3-1/85.76

Names and dimensions vary by manufacturer. Compute brick per square foot as 144 divided by the product of the horizontal and vertical repeats. Here that is 144/(8 × 2.625) = about 6.86 brick per square foot of wall face.

Worked example. The 30-foot by 9-foot wall has 270 square feet. Deduct two 3-by-5-foot windows and a 3-foot by 6-foot-8-inch door. Their areas are 30 and 20 square feet respectively, leaving 220 square feet. At the unrounded rate of 144/21, the field estimate is about 1,509 brick. With a stipulated 5 percent allowance and rounding at the end, the estimate is 1,584 brick. Order 1,590 if the supplier sells in increments of ten, after checking actual corner, return and cut requirements. The 108-inch height divided by the same 2-5/8-inch repeat gives about 41.14 repeats, so lay out the first and last beds, openings and trim instead of assuming that the elevation takes a whole number of courses.

Bond Patterns

Bond describes how units are arranged and where their joints fall. A structural masonry connection depends on the actual overlap, ties and reinforcement.

  • Running bond (half bond): each course offsets its head joints by half a brick. It is a common veneer arrangement.
  • Third running bond: one-third offset, used for appearance and for some engineered wall types.
  • Stack bond: head joints align in successive courses in this layout. Where the R606 prescriptive structural masonry rules apply, follow R606.3.7.2 for the horizontal reinforcement area and spacing and check any additional seismic requirements.
  • English bond: alternating courses of headers and stretchers. In traditional thick walls a true header can connect adjacent wythes.
  • Flemish bond: headers and stretchers alternate within a course. Decorative headers in a single wythe do not connect it to the backing.

The prescriptive R606.3.1 default for bed and head joints is ⅜ inch. Properly tooled concave, V and grapevine joints are water-resistant choices in exposed clay brick. Avoid profiles that leave ledges or uncompacted mortar in that exposure. Type N is often selected for suitable above-grade anchored veneer. Use the mortar the assembly and applicable code require.

Brick Paving and Fireplace Brick

Brick paving. For a typical residential sand-set patio or walk, BIA Technical Note 14A uses a nominal 1-inch loose sand bed, 3/4 to 1 inch compacted, over a compacted aggregate base typically at least 4 inches deep. Sand-filled joints and perimeter restraint keep the units in position. Size the base and any subbase for the traffic and soil and provide drainage away from the building. Mortar-set paving is also used under a different approved assembly with its own concrete base, drainage and movement details.

Fireplace brick. A masonry fireplace lining under R1001.5 may use ASTM C27 or C1261 firebrick laid in medium-duty refractory mortar complying with C199. R1001.11 generally requires 2 inches of clearance to combustibles at front faces and sides and 4 inches at back faces. It also has specified exceptions, including for some listed assemblies, trim and fireblocking. Under R1001.10 the hearth extension is at least 16 inches in front and 8 inches beyond each side for an opening under 6 square feet. For an opening of 6 square feet or larger, use 20 inches in front and 12 inches at the sides. Chapter 45 develops the fireplace and chimney assembly.

Test Your Knowledge

Which ASTM C216-13 grade is intended for a solid facing brick application with severe weathering and repeated freezing while wet?

A

Grade MW

B

Grade NW

C

Type FBX

D

Grade SW

Test Your Knowledge

A modular brick face is 7-5/8 inches long by 2-1/4 inches high, and both mortar joints are exactly 3/8 inch. About how many brick cover one square foot of wall?

A

About 6.86

B

About 4.61

C

About 5.50

D

About 8.00

Test Your Knowledge

Which bond pattern aligns the head joints in successive courses so that the units are directly above each other?

A

Running bond

B

Flemish bond

C

Stack bond

D

English bond