57.4 Construction & Hazardous Waste Disposal
Key Takeaways
Separate reusable and recyclable materials. Send nonhazardous debris for disposal to an authorized facility that accepts the stream. Michigan prohibits open burning of remodeling and demolition debris for disposal.
Under Michigan Part 111, determine the waste at generation before mixing. The very small quantity category includes at most 100 kg of non-acute hazardous waste per calendar month and separate limits for acute and severely toxic waste and spill residues.
Rule 228 supplies Michigan’s alternative universal waste requirements for eligible materials such as hazardous lamps and batteries. Packaging, labels, accumulation and destination requirements still apply.
Submit an ordinary covered asbestos NESHAP notice through EGLE’s MiEnviro portal at least 10 working days before the regulated start. Covered demolition can require notice even without asbestos. Check the separate Michigan abatement and notice rules.
Keep the designated facility’s signed manifest at least three years from initial transporter acceptance for a manifested SQG or LQG shipment. Tie each record to the waste stream, the receiving facility and the governing rule.
Sort the Waste at Generation
Under Michigan Part 115, send nonhazardous construction and demolition waste for disposal to an authorized facility that accepts that material. A licensed landfill can accept only streams allowed by its license and operating conditions. An authorized transfer station may take a load on its way to final disposal. Keep materials eligible for lawful reuse or recycling out of mixed disposal loads. Michigan prohibits open dumping and disposal burning of remodeling or demolition waste.
| Waste stream | Examples | Handling and destination |
|---|---|---|
| Clean ordinary debris | Untreated lumber, drywall, and asphalt shingles | Check recycling options and the authorized receiving facility's acceptance rules |
| Metal and clean masonry | Studs, flashing, concrete and brick | Use a legitimate recycler or other approved use or destination |
| Treated or painted wood | Decking, exterior trim and millwork | Screen for special rules and receiving-facility acceptance before hauling. Do not burn |
| Leftover liquids and product containers | Solvents, paints, adhesive and aerosol cans | Determine hazardous waste, universal waste or other applicable status before mixing. Michigan Part 121 may apply to liquid industrial by-products |
| Lead-painted debris | Trim, siding and windows | Apply covered RRP containment and determine the disposal rules. Qualifying residential debris can fall under the household exclusion. Evaluate other sources separately |
| Asbestos waste and equipment with PCBs | Insulation, certain flooring materials and some old ballasts | Identify and segregate. Use the management and receiving requirements applicable to the contaminant |
| Hazardous lamps and batteries | Fluorescent tubes and rechargeable packs | Use Part 111 Rule 228 if eligible. Check separate spent lead-acid battery requirements where applicable |
| Concrete washout | Water and solids from washing equipment | Collect in a leakproof washout system and arrange lawful reuse or disposal. Keep washout out of drains and waterways |
Michigan hazardous waste determination and generator category
Under Part 111 Rule 302, make the determination at the point of generation and before dilution, mixing or other alteration. Recheck if the waste may have changed in a way that alters its classification. Check exclusions first and identify listed waste. Evaluate characteristics such as ignitability, corrosivity, reactivity or toxicity using acceptable knowledge or tests. A product SDS can inform the determination. The process and what entered the waste after use also matter.
Rule 303, Table 1, uses amounts generated in a calendar month, subject to its counting rules:
| Category | Non-acute hazardous waste alone | Other amounts that matter |
|---|---|---|
| Very small quantity generator (VSQG) | 100 kg or less | At most 1 kg acute, at most 1 kg severely toxic, and at most 100 kg from cleanup of an acute or severely toxic spill |
| Small quantity generator (SQG) | More than 100 kg and less than 1,000 kg | The same limits for the other categories apply |
| Large quantity generator (LQG) | 1,000 kg or more | Also applies if any of the other limits is exceeded |
Older material calls the smallest category a conditionally exempt small quantity generator. Use VSQG under current Part 111 rules and apply Rule 304's conditions and separate on-site accumulation limits. The generator still characterizes waste and makes lawful arrangements for delivery. A normally small job can cross a monthly limit if several waste streams arise at once. Use the more stringent category when streams trigger different categories. Rule 303 excludes properly managed universal waste from the generator calculation.
Universal waste and legacy contaminants
Michigan Rule 228 offers an alternate route for eligible universal wastes. Keep fragile lamps in closed, sound packaging that prevents breakage, label them and send them to a handler or destination that can lawfully receive them. Track accumulation time. Most small handlers have a one-year limit unless the rule's exception is met. Treat releases as required for the material released. Keep old PCB ballasts separate from the universal waste lamps.
For covered paid renovation in pre-1978 housing or child-occupied facilities, the federal RRP rule calls for a certified firm and assigned certified renovator, applicable pre-renovation education, lead-safe work practices and containment of waste during storage and transport. Debris from eligible residential lead work may qualify as excluded household waste under 40 CFR 261.4(b)(1). A nonresidential job does not get that exclusion merely because the contractor also works on homes.
Keep Disposal Streams Separate
Staging and transport
Michigan Construction Part 1 Rule 119 requires safe piling or containment of scrap and debris, safe removal of combustible scrap at reasonable intervals and securing wind-prone material that could create a hazard. Use covered containers for putrescible garbage and empty them at frequent, regular intervals.
- Mark separate bins for clean recyclable material and ordinary debris. Confirm what the hauler and receiving facilities accept before the first pickup.
- Keep free liquids, batteries and uncharacterized waste out of ordinary debris containers. Classify the waste even if an absorbent has already been used for cleanup.
- Prevent material from spilling or blowing out during transport. Use leakproof washout containment and keep it clear of storm drains.
- In a hazardous waste accumulation area, select sound, compatible containers, prevent releases, separate incompatible materials and apply the labels, inspections and dates required for the generator category and area. For example, an eligible satellite container under Rule 305 normally stays closed and displays both the hazardous waste label and an indication of the hazards. Central accumulation dates are governed by the applicable central rules.
Open burning
A contractor cannot burn remnants from a demolished structure or remodeling waste for disposal. The limited fire-training route for an eligible standing structure has separate air and asbestos requirements and does not legalize a disposal fire. For an ordinary tear-off, arrange legitimate recycling or authorized disposal and keep the ticket.
Worked scenario
A planned office renovation will disturb 200 square feet of regulated asbestos-containing material (RACM) on facility components other than pipes. This exceeds the 160-square-foot threshold in 40 CFR 61.145(a)(4). The owner or operator submits the notice to EGLE through MiEnviro at least 10 working days before the ordinary asbestos disturbance. At the threshold the requirement already applies. Ordinary covered facility demolition has a separate advance notice requirement even when asbestos is absent. Ordered demolitions and emergency renovations follow their applicable special provisions.
For the office job, arrange applicable Michigan licensing and notify MIOSHA separately for nonemergency abatement exceeding 10 linear feet or 15 square feet of friable asbestos-containing material. Its ordinary advance notice is 10 calendar days, through the Michigan Asbestos Notification System. Meet Part 602 worker protection and use the trained on-site representative required by §61.145(c)(8) during covered RACM handling. Keep the asbestos shipment records required by §61.150 and choose a receiving site authorized for the waste.
The same office also yields nonhazardous plaster and metal, intact fluorescent lamps eligible for universal waste, and liquid wastes that the generator determines to be 80 kg of non-acute hazardous solvent and 40 kg of non-acute hazardous stain residues that count this calendar month. No other hazardous waste triggers a larger category. The total is 120 kg, so the generator is an SQG for the month. It keeps qualifying universal waste lamps separate and arranges shipment of the hazardous liquids to the designated facility with the required manifest and identification. The plaster goes to an accepting facility and the metal to a legitimate recycler. One disposal receipt would not document those separate streams.
Document the Destination
A manifest tracks a regulated shipment from generator to authorized receiving facility. Use the correct waste numbers and quantity, and compare the delivered copy with the shipment record. Federal electronic reporting requirements and Michigan's generator reporting rule both apply where triggered.
| Record | Retention or follow-up |
|---|---|
| Manifest signed at shipment by an SQG or LQG | Keep it for three years or until the copy signed by the designated receiving facility arrives |
| Manifest signed by the designated receiving facility | Keep it at least three years from the date the initial transporter accepted the waste. Extend retention if Rule 311 requires it |
| SQG or LQG waste determination records | Under Rule 311(1), at least three years from the last date the waste was sent to treatment, storage or disposal. Document the source, composition and determination basis |
| VSQG determination and generator records | Document how the amounts and waste types support the category and retain the records under applicable Michigan requirements and EGLE guidance |
| Solid waste and universal waste delivery | Keep scale tickets or recycling receipts as project records, and meet any specific tracking duties. A large quantity universal waste handler generally keeps its shipment records for at least three years |
| Covered asbestos disposal | Keep the waste shipment record and follow the separate return-copy and reporting clock under 40 CFR 61.150 |
Apply Michigan Rule 312 to missing hazardous waste delivery confirmations. For an LQG, check with the transporter or facility after 35 days without confirmation and file the applicable exception report if still unconfirmed after 45 days. For an SQG, Michigan requires reporting after 60 days without the receiving facility's signed copy. Measure from acceptance by the initial transporter for an ordinary shipment. The federal e-Manifest reporting process also applies as applicable. A missing signature is a follow-up event, rather than a reason to discard the shipping copy.
Jobsite closeout
Before work, survey the site for legacy materials and identify the person responsible for segregation, characterization and accumulation. Plan storage away from drains and egress and communicate where each stream goes. At each pickup, record the contents and receiving facility and reconcile the receipts or manifests as they arrive. File the records while they are still traceable to the shipment.
A homeowner asks a remodeling contractor to burn tear-off debris and old deck boards in the backyard to avoid disposal costs. What is the correct response under Michigan rules?
Burning is acceptable if the pile is small and the fire is attended
Do not burn the remodeling debris. Use lawful recycling where accepted or an authorized facility that can accept it for disposal
Burning is allowed with a written permit from the local fire department
Burning is allowed for untreated wood only, provided the ash is buried
For a manifested Michigan SQG shipment, what is the minimum retention period for the copy signed by the designated facility, and what starts that period? Assume no retention extension.
Until the generator receives the copy signed by the receiving facility
At least three years from the date the generator receives the signed copy
At least 60 days from the day the initial transporter accepted the waste
At least three years from the day the initial transporter accepted the waste
A scheduled interior renovation of a 1965 commercial building will disturb 200 square feet of RACM on facility components other than pipes. Which ordinary federal NESHAP notification step applies in Michigan?
Skip notice because the renovation will leave the structural frame standing
Call MIOSHA on the morning asbestos disturbance starts
A permit from the local building department only, since asbestos is a federal issue
Submit the notice through EGLE’s MiEnviro portal at least 10 working days before the asbestos disturbance
Sections you finish are checked off in the contents.