58.1 Protecting Workers & the Public

Key Takeaways

  • MIOSHA Part 22 Rule 2223 still incorporates Part 6 of the 2011 Michigan Manual on Uniform Traffic Control Devices for construction worker protection. The road authority administers the road agency’s separate traffic requirements.

  • Michigan released the 2025 MMUTCD on January 15, 2026. MDOT Design Advisory 2026-02 requires it from the August 7, 2026 letting for projects whose contract documents call for the latest edition, subject to the stated statewide target-date exception.

  • Use advance warning, transition, activity and termination areas as appropriate. A merge from two same-direction lanes uses different taper criteria from alternating two-way traffic through one open lane.

  • Rule 2223 requires Class 2 or 3 apparel for the traffic regulator and specifies paddle design and additional PPE. Check worker clothing duties and road agency specifications separately.

  • Part 20 Rule 2034 requires barricades at least 42 inches high and at least 6 feet back around the demolition drop path and receiving area, with warnings at each barricaded level. Rule 2033 separately governs protected employee egress and multistory demolition entrances.

Last updated: November 2026

Separate the People and the Hazards

MCL 408.1011(a) requires employers to protect employees from recognized hazards likely to cause death or serious physical harm. Part 22 Rule 2221 requires employers to provide and maintain the prescribed warning and protection devices where employees may be injured without an alert. For construction off the public right-of-way, Rule 2224 requires a barricade to keep employees away from a hazardous area when another standard does not already govern it.

Who or what is exposedWhat to assessApply the matching control
EmployeesFalls, cave-ins, dropped material, machinery and trafficApply the specific MIOSHA standard and route workers outside the hazard area
Pedestrians and neighborsDebris from overhead work, open holes and unauthorized entrySecure the perimeter and maintain a protected pedestrian route or an approved accessible detour
Drivers and cyclistsUnexpected narrowing, changes in direction or entry into the work spaceSet up the road authority's temporary traffic controls and maintain an understandable route
Adjacent structuresUndermining, settlement and movementUse the support and inspection provisions of Part 9 where applicable

Choose controlled gates and post warnings where people can act on them. Keep fencing and stockpiles clear of driveway and intersection sight lines. Plan how a delivery can enter without backing or swinging through a public route. Use fencing to control pedestrian access and a crashworthy barrier for vehicle intrusion where the plan calls for positive protection.

Pedestrian routes and overhead work

Arrange public sidewalk closures with the road or permitting authority before blocking the route. Give advance notice and preserve access to destinations and crossings. Where an accessible and detectable facility is affected, maintain those features along the alternate route. Use continuous detectable channelization where needed and keep the route clear of vehicle paths and work hazards.

Choose overhead protection under the applicable building-code and right-of-way requirements. For work covered by the 2021 Michigan Building Code, Chapter 33 and Table 3306.1 govern pedestrian safeguards. A covered route must provide usable passage and adequate lighting. Select the structure for anticipated loads and maintain the protection while people are exposed. In Michigan workplace demolition, Rule 2033 separately protects designated employee egress against falling material. The required canopy at an employee entrance to a multistory structure being demolished extends at least 8 feet outward, is at least 1 foot wider on each side, and supports 150 psf.

Preserve the Rule 2034 protection for a demolition material drop. Enclose the drop path and receiving area with barricades at least 42 inches high and 6 feet back from the opening and receiving area. Post falling-material warnings on the barricades at each barricaded level. A drop through several levels requires the prescribed enclosure, chute or intermediate barricades. For an interior drop of more than 40 feet, use only the enclosed opening or chute. Extend that enclosure through the receiving-level ceiling. Public pedestrian protection and employee demolition protection can both apply to the same operation.

Protect crossings and control debris

Part 9 Rule 951 prevents undermining sidewalks, pavement and appurtenant structures without employee protection such as suitable support. If an employee or equipment must or may cross a trench or ditch, provide the required walkway, runway, ramp or bridge with capacity of at least three times the imposed load and the prescribed guardrail. Check the separate rule for adjacent structures and keep people outside lifting and excavating drop zones.

Under Part 1 Rule 119, stack or contain scrap safely, remove combustible debris at reasonable intervals using a safe means, put putrescible garbage in covered containers and secure wind-prone materials that present a hazard. Keep exits, temporary routes and gate approaches usable throughout the shift.

Identify the Traffic Standard

Part 22 Rule 2223(1) uses Part 6 of the 2011 MMUTCD for worker protection at construction sites. The road authority's requirements are a separate obligation. MCL 257.608 authorizes adoption of the Michigan manual and §257.610 requires conformity for devices on roads under local and county jurisdiction. MDOT released the 2025 MMUTCD on January 15, 2026 as Michigan's adoption of the 11th federal edition. Under MDOT Design Advisory 2026-02, the August 7, 2026 letting begins its required use on MDOT contracts directly referencing the latest version, with the advisory's exception for separately coordinated target dates. Resolve the permit and contract requirements with the road authority while meeting the employee-protection rule.

A trained traffic regulator, also called a flagger, controls traffic and warns workers. Rule 2213 defines the work zone using the begin/end work signs, the convoy signs for qualifying multiple moving vehicles or a defined zone in front of and behind a qualifying single vehicle displaying a beacon or strobe. In that last case each boundary is 150 feet from the vehicle or the first-visible point on that side, whichever is closer. Check road authority authorization when directing traffic under MCL 257.611a.

For a Rule 2223 hand-held paddle, the bottom of the sign is at least 6 feet above the road, the octagon is at least 18 by 18 inches, and the lettering is at least 6 inches high. The normal faces are white STOP on red and black SLOW on orange. The rule addresses when two STOP faces are needed and specifies the reflectorized elements after dark. The employer provides, and the regulator wears, labeled ANSI/ISEA 107 Class 2 or 3 apparel meeting the rule's edition or equivalent revision, plus applicable head, eye and foot protection. Under 2011 MMUTCD §6E.02, regulator retroreflective material is visible from at least 1,000 feet, and Class 3 is recommended for consideration at night. Under §6D.03, the employer's designee selects the apparel class for exposed workers within the right-of-way, including exposure to work vehicles and equipment. The manual allows specific alternatives for responders.

Worked comparison at 35 mph

Identify the advance warning, transition, activity and termination areas before placing devices. The activity area includes work space, traffic space and any buffer space. A utility cut closes one direction's lane on a two-lane city street. The remaining lane must serve both directions in turn. The plan needs advance warning on both approaches, a one-lane, two-way taper, coordinated controls such as trained regulators, and a protected work area. In the 2011 manual's §6C.08 guidance, the one-lane, two-way taper is 50 to 100 feet with devices about 20 feet apart. Keep the buffer clear of work and storage. For a downstream taper returning traffic to the original lane, Michigan §6C.08 recommends 50 to 100 feet with devices about 20 feet apart.

Compare a different job where one of two adjacent same-direction lanes closes and drivers merge. Under the 2011 MMUTCD taper criteria, when the appropriate speed is 35 mph and the lateral offset is 12 feet, the merging length criterion is L = W × S² / 60 = 12 × 35² / 60 = 245 feet. At 40 mph or less use L = W × S² / 60. At 45 mph or more, the table uses L = W × S. The same table uses at least L for merging, at least ½L for shifting and at least 0.33L for a shoulder taper when used. Use the applicable speed basis and account for sight distance, road geometry and the approved plan. The 245-foot result belongs to the same-direction merge.

Walk the route before opening the work area. Check warning visibility from both approaches, vehicle paths and buffers, pedestrian continuity, enclosure and lighting. Recheck after the operation moves or conditions change.

Test Your Knowledge

Which manual provision does Michigan Construction Part 22 Rule 2223(1) expressly incorporate for traffic control devices protecting construction workers on a city street?

A

Part 9 of the Michigan construction safety standards because the project includes a trench

B

Part 6 of the 2011 Michigan Manual on Uniform Traffic Control Devices

C

Part 6 of the 2025 Michigan Manual because its release automatically amended Part 22

D

The contractor’s equipment handbook if it describes equally visible devices

Test Your Knowledge

One of two same-direction lanes closes. Drivers must merge into the remaining lane. Under the 2011 MMUTCD, what merging taper length does Table 6C-4 give for a 12-foot offset and a speed basis of 35 mph?

A

70 feet

B

About 123 feet

C

420 feet

D

245 feet