52.2 Window & Door Materials & Parts
Key Takeaways
In Michigan’s prescriptive component table, the maximum U-factor is 0.32 for fenestration other than skylights and 0.55 for skylights in zones 5A, 6A and 7.
Apply the Michigan rating provision in N1101.12.3. A clear double-pane nonmetal window without a label or accepted alternative uses the 0.55 table default.
A true divided-lite sash has bars that separate and hold individual panes. A decorative grille simulates separate panes.
Michigan’s product air-leakage rule limits windows, skylights and sliding glass doors to 0.3 cfm/ft² and swinging doors to 0.5 cfm/ft². Site-built units are excepted.
Compare complete unit U-factors and use the frame and glazing details to understand their differences. A thermal break interrupts the heat path through a metal frame.
Frame materials set the thermal floor
Michigan’s prescriptive component table N1102.1.1 gives a maximum U-factor of 0.32 for fenestration other than skylights and 0.55 for skylights in climate zones 5A, 6A and 7. Use the county table for the project’s zone. A rated U-factor describes heat transfer through the entire unit, including its glazing, frame, edge spacer and sash.
Michigan N1101.12.3 (Rule 547c) uses NFRC 100 and a manufacturer-certified label based on an accredited, independent laboratory determination. For products without that label, use the default under Table N1101.12.3(1) for glazed units or the applicable door table, subject to the allowed independent NFRC-certified simulation or approval under MCL 125.1521. The glazed unit table gives these values.
| Frame type | Single pane | Double pane | Skylight single | Skylight double |
|---|---|---|---|---|
| Metal | 1.20 | 0.80 | 2.00 | 1.30 |
| Metal with thermal break | 1.10 | 0.65 | 1.90 | 1.10 |
| Nonmetal or metal clad | 0.95 | 0.55 | 1.75 | 1.05 |
The table assigns glazed block a default of 0.60.
For example, a clear double-pane vinyl window qualifies as double-pane nonmetal. With no labeled rating or accepted alternative, its default is 0.55. A standalone comparison with the 0.32 prescriptive component maximum fails. Compare the rating for the selected unit before ordering, or document the applicable compliance path.
| Frame | Thermal and construction detail | What to inspect |
|---|---|---|
| Wood | Relatively low conductivity | Coating, exposed ends and sill drainage |
| Vinyl (PVC) | Profile may use hollow or insulated chambers | Finish and product clearances for movement |
| Aluminum | Conductive metal frame | Thermal break and tested whole-unit rating |
| Aluminum-clad wood | Exterior cladding covers wood members | Cladding joints and drainage details |
| Fiberglass | Profile may contain insulated cavities | Glazing, finish and anchorage for the selected profile |
| Composite | Properties depend on the material blend | Performance data and maintenance instructions |
To compare two frames with similar glazing, start at the edge of the glass. The spacer joins the lites, and the material around it provides a heat path to the exterior. A thermal break in metal or an insulating frame profile can limit that path. The complete product rating accounts for the interaction of the glazing and frame.
Select a sealant joint compatible with the frame and wall materials. Allow movement at the transition and use the specified backer and joint dimensions. The frame-to-wall air seal is a separate detail from the factory assembly rating.
On the prescriptive component path, compare these clear double-pane vinyl windows individually with the 0.32 maximum. They have no labeled U-factor or accepted alternative. What default applies and how does it compare?
0.32, which meets the maximum
0.55, which meets the maximum
0.55, which exceeds the maximum
0.95, which exceeds the maximum
Glazing: the part you look through
Single glazing has one lite. In a typical double-pane insulated glass unit (IGU), two lites enclose a sealed cavity and a spacer holds their separation. Triple glazing adds another lite and cavity. Check the whole unit’s U-factor and make sure operable sash hardware is sized for its actual weight.
Glazing features change how the unit transfers heat and light.
- Low-emissivity coating: limits radiant heat transfer. Its type and surface placement affect U-factor and solar gain.
- Argon or krypton fill: reduces heat transfer through the glazing cavity. Krypton can be used in narrower cavities.
- Tint: can reduce solar gain and visible light. Compare both ratings for the planned orientation and shading.
- Warm-edge spacer: reduces heat transfer at glazing edges and can reduce edge condensation.
- Solar heat gain coefficient (SHGC): measures the fraction of incident solar energy admitted through the product. Visible transmittance measures the fraction of visible light transmitted.
Read the product label or listed values for the selected configuration. Under amended N1102.4.3 (Rule 547d), windows, skylights and sliding glass doors have a product infiltration maximum of 0.3 cfm/ft², and swinging doors 0.5 cfm/ft². An accredited independent laboratory tests to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440, and the manufacturer lists and labels the unit. Site-built windows, skylights and doors are excepted from this product provision.
Anatomy: naming the parts
The frame includes a head, side jambs and sill. The sash holds the glazing. Its vertical members are stiles and the horizontal members are rails. Glazing beads or stops help retain the glass. Setting blocks, seals and retention details vary by glazing system.
In a true divided-lite unit, bars called muntins divide and hold separate lites. A decorative grille can create the same pattern on or between panes of a larger glazing unit. Some product catalogs also call decorative grilles muntins, so identify the construction by whether it holds separate panes.
Weep holes drain a frame or track where the unit uses them. Weatherstripping seals the moving sash to the frame, and a balance supports the sash in a hung window. A nailing flange attaches compatible units at the exterior face. A slider’s interlock engages the meeting stiles when closed. Use the unit instructions for cleaning and maintenance of the interlock and drain paths.
Door parts and hardware
The slab is the moving door panel. Its material and core depend on the unit and the intended application. The jamb frames the head and sides. The threshold or sill assembly closes the bottom of an exterior opening, and the sweep seals to it. Brickmold is exterior trim around the opening. Integrate it with the approved flashing detail. Interior casing covers the jamb-to-wall joint. On a paired door, an astragal can close the joint at the meeting edge.
The hinges carry and swing the slab. The latch extends into a strike at the jamb, and the deadbolt, if present, secures the door. Check swing, reveal and latch alignment with the specified jamb supports and fasteners. Match the hardware and core to the listed exterior assembly, and apply the relevant door size and access requirements for the setting.
Which listed component simulates smaller panes in an intact insulated glazing unit?
A decorative grille between the panes
A true divided-lite bar that separates individual panes
A sash stile
A glazing bead
Under Michigan N1102.4.3, what product air-infiltration limits apply to factory-built windows, skylights and doors?
0.3 cfm per square foot for all doors and windows
No limit for swinging doors
0.5 cfm per square foot for windows and 0.3 for swinging doors
0.3 cfm per square foot for windows, skylights and sliding glass doors, and 0.5 for swinging doors