52.1 Window & Door Types
Key Takeaways
A fixed sash contributes glazing area and provides no openable area. Under R303.1, the ordinary habitable-room criteria are glazing of at least 8 percent of floor area and openable area to the outdoors of at least 4 percent, subject to the listed exceptions.
Measure emergency escape and rescue openings in the normal open position. The ordinary R310 window thresholds are 5.7 square feet net clear (5.0 at grade floor or below grade), 24 inches high, 20 inches wide and a sill no higher than 44 inches.
A casement pivots on a side jamb, an awning hinges at the head and opens out, and a hopper hinges at the sill and opens in. Check how far the sash and hardware project in the selected opening.
Michigan Rule 518 requires a side-hinged exit door at least 36 inches wide by 80 inches high. Check the separate door-size provision for other exterior hinged or sliding doors.
R308.6.8 requires unit skylights on roofs flatter than 3:12 to use a curb at least 4 inches above the roof plane unless the manufacturer specifies otherwise.
Window operators: how the sash moves decides what it can do
The window operator determines which sash moves and where it projects. The product’s weather seals, frame and glazing determine performance along with installation. Use the model’s operating and clear-opening dimensions when selecting a window for a particular location.
Vertical sliding: double-hung and single-hung
Both sashes in a double-hung window slide vertically. Balances support the operating sashes, and some models tilt inward for cleaning. Opening the lower sash admits air low in the unit, and opening the upper sash gives a second path. If a sash will not hold its position, inspect its balance and connections.
The upper sash of a single-hung window stays fixed while the lower sash moves. Check the travel of the lower sash and its actual opening. In equal-sash units it can uncover about half the window, with the usable area reduced by the frame and hardware.
Hinged and cranked: casement, awning, hopper
A casement hinges on a vertical side jamb. Some models crank outward, while others use a push-out handle. A gasket compressed at the sash perimeter can help limit leaks. Compare actual ratings and check whether the open sash projects over a walkway. A casement can provide a large clear opening, depending on sash swing and hinge geometry.
An awning window hinges at the head and its lower edge swings outward. The projecting sash can shelter some of the opening in light rain. A hopper hinges at the sill and swings inward at the head. Allow space inside for the sash and its hardware. Where either type is proposed for escape, check the clear passage with the sash in its operating position.
Sliding, fixed and projecting units
One or more sashes of a gliding window move horizontally on tracks. In a common two-sash model, one sash slides past the stationary sash. Other layouts open a different fraction of the frame. Check clear travel, track drainage and the meeting-stile seals. A picture window stays fixed. It can be combined with operating side units where glazing and airflow are both needed.
A bay combines units in an angular projecting assembly. A bow uses several units to form a curved projection. Fixed and operable units can be combined. Provide support as specified for the projecting unit and its loads. If the design includes a roof over the projection, integrate its wall flashing and support. Verify any proposed escape opening at the individual operable unit.
| Type | Moving part | What to check |
|---|---|---|
| Double-hung | Both sashes slide vertically | Balance, travel and meeting rails |
| Single-hung | Lower sash slides vertically | Clear space at the open lower sash |
| Casement | Side-hinged sash swings outward | Clearance outside and hinge position |
| Awning | Top-hinged sash swings out at the bottom | Clear passage around the open sash |
| Hopper | Bottom-hinged sash tips in at the top | Interior clearance |
| Slider | One or more sashes glide sideways | Travel, tracks and interlock |
| Picture | Fixed glazing | Glazing area and a separate ventilation provision |
| Bay or bow | Movement varies by individual unit | Projection support and flashing |
A new sleeping room needs an operable emergency escape and rescue opening. Which window has no normal operating position that provides an opening?
A fixed picture window
A casement with a full-height operating sash
A double-hung with both sashes operable
A gliding slider whose panel opens half the frame
Doors: swing, slide, fold and stack
Entry doors. Under amended MRC R311.2 (Michigan Rule 518), the required exit door is side-hinged and at least 36 inches wide by 80 inches high. Other exterior hinged or sliding doors must be at least 24 inches wide by 78 inches high. These are the dimensions in the Michigan amendment. Measure the clear passage separately where a governing accessibility or design requirement specifies it. Check the door’s operation, latch, sweep, threshold and perimeter seals before trim.
French doors have glazed hinged leaves. A pair may have one active and one inactive leaf. Verify the model’s swing and opening clearance. An astragal can close the meeting joint at the inactive leaf. At an exterior pair, check the meeting stiles and threshold along with the applicable opening-flashing instructions. Under R703.4 Item 1.1, where the applicable instructions give no flashing detail, provide a draining sill pan and protect the head and sides.
Patio sliders move horizontally. Check the interlock, track, latch and outlet at the threshold. Under amended N1102.4.3, the product air-leakage maximum is 0.3 cfm/ft² for sliding glass doors, windows and skylights and 0.5 cfm/ft² for swinging doors. The section excepts site-built units.
A storm door mounts outside the main entry door. Some models have a movable glass panel and insect screen for ventilation when the main door is open. A screen door uses mesh to admit air while excluding insects. Michigan’s amended N1101.3.1 allows storm windows installed over existing fenestration, and glass-only replacement in an existing sash and frame, to be exempt from new-construction energy requirements if the building’s energy use does not increase.
A pocket door slides into a wall cavity using an overhead track and pocket frame. It frees the swing area. Coordinate services, wall fasteners and structural support so the slab can travel unobstructed. A bifold door uses hinged leaves that fold together on pivots with a guide or overhead track. Check the clearance for the folded leaves in the opening.
A sectional garage door moves along tracks on rollers. Its spring and hardware counterbalance the door. Under R609.4, the garage door is tested to ASTM E330 or ANSI/DASMA 108 and meets ANSI/DASMA 108 acceptance criteria. If an automatic operator is provided, R309.4 requires a listing and label to UL 325. Follow the operator instructions for testing its safety devices.
Skylights: fixed or venting, on a curb or on the deck
A fixed skylight provides daylight. A venting skylight also has an operating sash, so check the operator, open position and weather seals.
A curb-mounted unit sits on a raised curb. Under R308.6.8, a roof flatter than 3:12 requires a curb at least 4 inches above the roof plane, unless the unit instructions specify otherwise. A deck-mounted unit attaches to the roof deck. Match the flashing kit and underlayment sequence to the unit, covering and pitch. Under R308.6.9, unit skylights and tubular daylighting devices require independent testing and a label indicating compliance with AAMA/WDMA/CSA 101/I.S.2/A440.
Matching the type to the job
Start by separating the three opening functions. Under R303.1, the ordinary habitable-room criteria are glazing of at least 8 percent of floor area and openable area outdoors of at least 4 percent. The section lists alternative methods. A 150-ft² room on the ordinary natural-light and ventilation path needs 12 ft² of glazing and 6 ft² of openable area. A fixed 12-ft² lite supplies the glazing in that example. An operable unit or other approved opening supplies the ventilation.
An emergency escape and rescue opening has its own R310 test. Measure the opening by normal operation from inside. The usual minimum is 5.7 ft² net clear, or 5.0 ft² at grade floor or below grade, along with a clear height of at least 24 inches, clear width of at least 20 inches, and a window sill no higher than 44 inches above the floor. Operate the unit as the occupant would, then measure the narrowest clear passage. Check the other R310 provisions before accepting it.
A plan shows unit skylights on a roof pitched at 2 units vertical in 12. What does MRC R308.6.8 require?
Deck mounting with butyl tape at the flange
No curb, provided the unit is labeled to AAMA/WDMA/CSA 101/I.S.2/A440
A curb at least 2 inches above the roof plane
A curb at least 4 inches above the roof plane, unless the manufacturer's instructions specify otherwise
Which statement correctly describes awning and hopper windows?
Both hinge on a vertical jamb and crank outward
An awning is hinged at the head and pushes its sill outward, while a hopper is hinged at the sill and tips its head inward
An awning tips inward at the head and a hopper projects outward at the sill
Both provide a clear opening equal to the full rough opening
Sections you finish are checked off in the contents.