55.1 Tile at Showers & Floor Transitions
Key Takeaways
Check shower wall backer, waterproof continuity and the actual drain connection together.
Michigan P2709.2 sets a 3-inch extension around or beyond rough jambs and above the finished threshold for the receptor lining.
Evaluate each run to the drain at the required finished slope. Compare finished floor heights before choosing a doorway transition.
Check the liner by the applicable water test and preserve the movement and waterproofing details at changes of plane.
Plan the Transition from Shower to Bathroom
Lay out the fixed drain, shower wall, doorway, finished floor and any threshold before the tile is ordered. The framed opening and nominal tile thickness alone do not determine the finished dimensions. Include the actual backer, membrane, setting bed, tile and any transition profile. Select wet-area-rated surfaces and compare the allowed tile size with the drain and slopes. A tiled shower floor must drain across its finished surface.
Support, waterproofing and drainage
-
Wall assembly. Check framing stiffness and flatness, then select a backer listed under Michigan R702.4.2. A permitted panel can be part of the waterproof assembly. Follow its fastener and joint detail. For example, the HardieBacker wall procedure calls for its specified fasteners, mortar and alkali-resistant mesh tape. That example concerns the backer. Complete the separate waterproofing detail, including membrane seams, wall-floor junctions, corners and pipe penetrations. Under R307.2, the required nonabsorbent wall finish extends at least 6 feet above the floor in the stated tub and shower locations.
-
Receptor. Michigan Rule 529 amends P2709.2 for on-site built-up receptors. It lists sheet lead, sheet copper, qualifying ASTM D4068 or D4551 plastic liner, and qualifying sheet-applied ANSI A118.10 bonded membrane. It requires the lining to extend at least 3 inches beyond or around the rough jambs and 3 inches above the finished threshold. Apply a bonded sheet system per its instructions. For the traditional liner under P2709.3 and P2709.4, pitch the formed subbase 1/4 inch per foot toward the drain weep holes, keep those paths open and check the watertight flanged connection. Recess the liner into its backing where required to keep the wall plane flat. Keep nails and other perforations at least 1 inch above the finished threshold. The slope under the traditional liner and the slope on top of the finished tile are separate inspection points. A bonded surface membrane can connect to a compatible bonding-flange drain. Confirm the drain, membrane and other components form one approved assembly. For example, follow the Schluter system for the membrane-to-flange connection and the required seams and corners when using that named assembly.
-
Verification. P2709.1 requires the finished receptor floor to slope uniformly to the drain from 1/4 to 1/2 inch per foot. Inspect drainage and junction details while visible. For a site-built liner in P2709.2, follow the P2503.6 plugged-drain test before tile. Use at least 2 inches of water measured at the threshold, constructing a temporary threshold as needed, and hold it for at least 15 minutes without leakage. Follow the system's additional cure and test requirements. If the selected membrane needs 24 hours to cure before testing under the stated product conditions, budget that time. Confirm any accessible or curbless design separately before adjusting the threshold.
Worked choice: 36-inch run and a doorway
The longest path to a drain is 36 inches. At 1/4 inch per foot, the high tile surface at the start of that path sits 3/4 inch above the drain elevation, since 36 inches is 3 feet. At 1/2 inch per foot it is 1-1/2 inches higher. Check shorter paths separately to keep the slopes in range, especially if the drain sits off center. If a level perimeter puts that same 3/4-inch rise on a 15-inch path, its slope is 0.60 inch per foot and exceeds the 1/2-inch maximum. Draw the shortest path before setting the perimeter. Reposition the drain or adjust the layout if the planned geometry cannot satisfy both runs.
At the dry bathroom doorway, measure the two finished floor elevations independently from the same reference. If the tile is 3/8 inch higher than the adjacent floor in a project with no special accessibility requirement, choose a reducer or compatible profile sized to that difference and detail the gap so adjoining floors can move. If accessibility provisions apply, select the actual threshold and slope from those requirements. At a shower inside corner or dry floor perimeter, use the specified movement joint, such as a compatible flexible sealant or approved profile. The joint at the finish surface and the waterproof connection behind it serve separate functions.
The longest finished shower floor run is 36 inches. At 1/4 inch per foot, what elevation difference should the layout show?
1/4 inch
1/2 inch
3/4 inch
1-1/2 inches
A contractor proposes a bonded sheet membrane for a site-built Michigan shower. What should be confirmed before tiling?
The membrane and drain are an approved combination, lining extensions match Michigan’s rule and the assembled liner passes the applicable water test.
The grout selected for the corners can replace the liner.
The backer is cementitious, so the drain-to-membrane joint can be left open.
The finish extends six feet on the wall, so no liner test is needed.
Sections you finish are checked off in the contents.