46.1 Roof Covering Materials & Installation
Key Takeaways
R905.2.2 sets a 2:12 minimum slope for asphalt shingles. The standard Table R905.1.1(2) method uses double coverage below 4:12 and one shingle-lapped layer at 4:12 or above. Check the ultimate-wind column and the separate R905.1.1 alternatives.
R905.2.5 specifies ASTM F1667 roofing nails of galvanized steel, stainless steel, aluminum or copper, with at least a 12-gage shank and 3/8-inch head. They penetrate the covering and at least 3/4 inch into the sheathing or through thinner sheathing. R905.2.6 sets the attachment minimum at four fasteners per strip or two per individual shingle, subject to the manufacturer’s required count and steep-slope instructions.
Match the ASTM D7158 label to the project’s design wind in Table R905.2.4.1. ASTM D3161 is the exception for shingles outside D7158’s scope. Choose the installation pattern and valley detail for the specific shingle.
Michigan’s Table R301.2(1) shows Yes for ice barrier and footnote (h) sets local designation criteria. Apply R905.1.2 in designated areas for the covered assemblies, with its detached unconditioned accessory exception.
Price field shingles using sloped surface area, waste and actual coverage per bundle. At 33⅓ ft² per bundle, 1,500 ft² plus 10% waste takes 50 bundles if sold individually.
The PSI Practice/Trade outline allocates 7 of 110 scored trade questions to Roofing. Start by choosing a covering suited to the roof slope. For asphalt shingles, R905.2.1 requires a solidly sheathed deck. Over that deck, coordinate the eave barrier where required, field underlayment, edge metals and flashing. The starter, field shingles and ridge caps complete the drainage path. At the eaves, underlayment goes over the drip edge. At rakes, the metal goes over the underlayment (R905.2.8.5 and ICC errata).
Asphalt Shingle Types and Required Labeling
A three-tab shingle commonly has a single body with cutouts that make several tabs. A laminated or dimensional shingle uses multiple layers for texture and depth. Fiberglass mat and mineral granules are common in both. Use the product instructions for the installed exposure, approved starter and valley detail. For example, GAF advises against weaving Timberline laminated shingles, while Owens Corning allows a woven valley for its Duration Series. Compare the installed assembly’s classifications and warranty terms for the chosen products.
R905.2.4 specifies ASTM D3462. For wind, check the packaging for the ASTM D7158 classification allowed by Table R905.2.4.1 at the project’s ultimate design wind speed. For shingles outside the scope of D7158, the code uses the ASTM D3161 classification from the same table. The table’s D7158 calculations assume Exposure B or C and a building height no greater than 60 feet. Outside those limits, obtain the additional calculations required by footnote (a).
The Michigan amendment prints 90 mph in Table R301.2(1). Footnote (d) directs the jurisdiction to the wind map and requires site-specific exposure under R301.2.1.4. Confirm the applicable design value and which wind-speed basis it uses. For example, Table R905.2.4.1 pairs 90 mph nominal with 116 mph ultimate and allows D, G or H under D7158 on that row. Its D3161 exception column allows A, D or F there. A site with a different design speed or exposure requires its own check. A manufacturer warranty wind speed and a code wind classification serve different purposes.
Other Coverings and Slope Limits
| Covering | 2015 MRC section | Minimum slope and assembly check |
|---|---|---|
| Asphalt shingles | R905.2 | 2:12. Use a solid deck and the asphalt row of the underlayment tables. |
| Metal roof panels | R905.10 | 3:12 for lapped nonsoldered seams without sealant, 1/2:12 with approved lap sealant, or 1/4:12 for standing seam. Check the selected panel system. |
| Metal roof shingles | R905.4 | 3:12. Select the underlayment under R905.1.1. The application and attachment tables use manufacturer instructions below 140 mph ultimate. |
| Clay and concrete tile | R905.3 | 2½:12. Check dead load, underlayment and the tile attachment provisions, including the snow-area rule. |
| Wood shingles and wood shakes | R905.7 and R905.8 | 3:12 for each. Shakes use ASTM D226 Type I interlayment under R905.8.4. |
| Slate shingles | R905.6 | 4:12 and a solid deck. Confirm the structure can handle the installed load. |
| Mineral-surfaced roll roofing | R905.5 | 1:12 and a solid deck. ASTM D3909 or D6380 Class M also identifies material permitted for the two-ply open asphalt-shingle valley. |
R905.1.2 includes asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles and wood shakes in designated ice-barrier areas. Section 46.2 works out the eave dimensions. For reroofing, use the structural and recover checks in Section 46.4.
Slope and Underlayment for Asphalt Shingles
Match the material, application and attachment using the three tables under R905.1.1. Their wind columns use ultimate wind speed.
| Asphalt-shingle slope | Standard application below 140 mph ultimate (Table R905.1.1(2)) |
|---|---|
| Below 2:12 | R905.2.2 excludes asphalt shingles. Specify a covering approved for the slope. |
| 2:12 to below 4:12 | Begin at the eave with a 19-inch starter strip. Lay the first 36-inch sheet from the eave and overlap each successive sheet by 19 inches to provide double coverage. |
| 4:12 and above | Apply one layer from the eave upward with 2-inch shingle laps and 4-inch end laps. Stagger successive end laps by 6 feet. |
At 140 mph ultimate or more, the asphalt-shingle application follows the same slope categories with a 4-inch minimum for laps. The 19-inch low-slope lap already exceeds that floor. Keep the sheet flat so the shingles can seal.
Table R905.1.1(1) lists ASTM D226 Type I, D4869 Types I–IV and D6757 below 140 mph ultimate. For the higher wind column, it lists D226 Type II, D4869 Type IV and D6757. Check the label. Table R905.1.1(3) requires fastening sufficient to hold the sheets in place below 140 mph ultimate. At or above 140 mph use the specified corrosion-resistant cap nails or cap staples with nominal caps at least 1 inch across. The grid is 12 inches between side laps and 6 inches at side laps. Use the cap and fastener dimensions in the table and a length that reaches through the sheathing or at least 3/4 inch into it. The manufacturer’s instructions may give a more specific attachment pattern.
The two alternatives in R905.1.1 have different assemblies. One uses ASTM D1970 self-adhering polymer-modified bitumen installed as directed by both the underlayment and covering manufacturers for that deck, ventilation and climate. The other seals every deck joint with a D1970 strip at least 4 inches wide and covers the entire roof with an approved underlayment for the covering from the below-140-mph material column. A generic synthetic label alone does not establish approval under this edition.
Installing the Asphalt-Shingle System
- Inspect the deck. Repair damaged areas. Check the shingle manufacturer’s minimum substrate, condition and fastening requirements.
- Install the eave drip edge, then the specified eave ice barrier and field underlayment. Install rake edge metal over the underlayment. R905.2.8.5 requires at least 2 inches of overlap between segments, at least 2 inches onto the deck and a drop of at least 1/4 inch below the sheathing. Mechanically fasten at no more than 12 inches on center with R905.2.5 fasteners.
- Prepare valleys and flashings. Put in the approved valley lining before shingles (R905.2.8.2). Integrate step flashing with each course. Use the manufacturer’s detail at penetrations and walls.
- Install the starter at each required edge, with the sealing strip positioned to bond the first course as the manufacturer directs.
- Lay field shingles upward from the eave. Use the wrapper’s course exposure, offset and nail zone. As one product example, Owens Corning’s Duration Series specifies 5⅝ inches of exposure and a 6½-inch starting offset.
- Finish hips and ridges with the specified cap and vent components. Use the cap manufacturer’s instructions for lap direction and fastener length through the assembled layers.
Choosing and Placing Fasteners
R905.2.5 sets the nail specification. Choose ASTM F1667 roofing nails of galvanized steel, stainless steel, aluminum or copper. The shank must be at least 12 gage and the head at least 3/8 inch in diameter. Nail length must account for the layers above the deck and reach at least 3/4 inch into the sheathing. Through-penetration is required where the sheathing is thinner, such as 7/16-inch OSB.
R905.2.6 sets attachment. Meet the manufacturer’s fastener count with a code minimum of four per strip shingle or two per individual shingle. For slopes greater than 21:12, follow the manufacturer’s steep-slope installation. For example, Owens Corning’s Duration Series specifies six fasteners and hand sealing in its steep-slope instructions. Use the specified nailing zone, drive nails straight and leave heads flush. A proud head can interfere with seating the next course, and an overdriven head can damage the shingle mat.
Worked Example: Ordering Field Shingles
The actual shingle surface measures 1,500 ft². If taking off from horizontal plans, include roof overhangs in the plan area and multiply each plane by its pitch factor. For a 6:12 pitch that factor is √(1 + (6 ÷ 12)²) ≈ 1.118. For 8:12 it is about 1.202.
- Convert area to squares: 1,500 ÷ 100 = 15 squares. Allow 10% for field cuts and waste, giving 1,650 ft² or 16.5 squares.
- Assume the selected shingle covers 100 ft² per three bundles and the supplier sells bundles individually. Then 1,650 ÷ (100 ÷ 3) = 49.5 bundles. Order 50 bundles.
- Product coverage can differ. Owens Corning lists 98.4 ft² per three nominal Duration bundles. Under that coverage assumption, 1,650 ÷ (98.4 ÷ 3) ≈ 50.31, so order 51 bundles. Take off separately packaged starter and ridge cap by their stated coverage.
Round at the unit you buy, after allowing for cuts and checking the selected product’s coverage.
A 3:12 asphalt-shingle roof uses the standard underlayment application in Table R905.1.1(2) of the 2015 MRC. The ultimate design wind speed is below 140 mph. Which installation follows that table?
One layer with 2-inch shingle laps over the entire field
Underlayment only at the eave, with the rest of the deck uncovered
A 19-inch eave starter strip with 36-inch sheets from the eave, overlapping successive sheets by 19 inches
A 19-inch eave starter strip with 36-inch sheets overlapping successive sheets by 4 inches
Which fastener description satisfies MRC R905.2.5 for attaching asphalt shingles over a 7/16-inch OSB deck?
An ASTM F1667 galvanized roofing nail with a 3/8-inch head and 12-gage shank, long enough to go through the roofing and the sheathing
A galvanized finish nail with a 5/16-inch head driven 1/2 inch into the OSB
Any nail of any length, as long as six fasteners are used in every shingle
Gage-16-leg staples, because they hold better than nails in wind uplift tests
A roof has 1,800 ft² of actual shingle surface. Allow 10 percent for field cuts and waste. The selected product covers 100 ft² per three bundles, and the supplier sells individual bundles. How many bundles should be ordered?
54 bundles
60 bundles
59 bundles
66 bundles
Sections you finish are checked off in the contents.