27.1 Drainage & Water Work Code Requirements
Key Takeaways
2015 MRC R401.3 requires lots to be graded so surface water drains away from foundation walls, with the grade falling a minimum of 6 inches (152 mm) within the first 10 feet (3 048 mm), which is a 5 percent slope.
R401.3 requires drains or swales where physical barriers prevent 6 inches of fall within 10 feet. Impervious surfaces within 10 feet must slope at least 2 percent away from the building.
2015 MRC R405.1 requires drains around concrete or masonry foundations that retain earth and enclose habitable or usable space below grade; gravel or crushed stone drains must extend at least 1 foot beyond the outside edge of the footing and 6 inches above the top of the footing, covered with an approved filter membrane. R405.1 exempts foundations installed on well-drained ground or qualifying Group I soils.
2015 MRC R801.3 requires a controlled method of roof water disposal that discharges roof drainage to the ground surface not less than 5 feet (1 524 mm) from foundation walls, or to an approved drainage system, where expansive or collapsible soils are known to exist.
A 2 percent slope equals 0.24 inch of fall per foot and a 5 percent slope equals 0.6 inch per foot, so 6 inches of fall in 10 feet is exactly 5 percent, not 6 percent.
Water control starts with the site plan. Trace roof runoff, surface flow and groundwater from where each enters the site to the approved outlet. Then check the grade and drainage details before backfill conceals them.
The enforceable residential code in Michigan is the 2015 Michigan Residential Code (MRC), which is the 2015 IRC with Michigan amendments; the 2021-based rules are enjoined, so the 2015 section numbers and dimensions below control. Use it for work within the residential code’s scope and check local stormwater and discharge requirements separately.
Start With Four Questions
Every drainage design, whether it is a full civil plan or a shovel and a string line, answers the same four questions:
- Where does the water come from? Roof runoff, surface sheet flow, groundwater, and off-site water running downhill onto the lot are different problems with different fixes.
- Where is the legal point of discharge? A storm sewer, a roadside ditch under permit, a designated drainage easement, a retention basin, or a designed overland swale that leaves the property at a defined low point.
- How does the water get there? Check whether graded swales and pipes can reach the outlet by gravity. A designed pump system can serve a low point without a gravity outlet.
- What happens when the storm exceeds the design? An overland relief path that does not run through the basement, the garage, or the neighbor's foundation.
Gravity is the governing principle. Water has to move downhill continuously from the highest point on the lot to the approved discharge point. Check for unintended low spots and reverse grades that can pond against a wall or across a walk.
Surface Water Versus Groundwater
| Water source | How it behaves | Primary control |
|---|---|---|
| Roof water | Concentrated, high volume, delivered at one point | Gutters, downspouts, splash blocks or buried leaders, route to a suitable outlet away from the foundation |
| Surface runoff | Sheet flow across lawns, driveways and patios | R401.3 grading, swales, diversion berms, impervious surface slope |
| Groundwater | Levels and flow vary with soil, site and season | Footing drains, dampproofing or waterproofing, sump pump, free-draining backfill |
| Off-site water | Arrives from an uphill parcel, often through an easement | Interceptor swale or diversion ditch at the uphill property line, engineered outlet |
Surface water is a grading problem. Groundwater is a foundation-drainage and waterproofing problem. Confusing the two is one of the most common design mistakes: intercept hillside runoff at the surface and design the foundation drain and waterproofing for subsurface water conditions.
The 2015 MRC Drainage Rule (R401.3)
Section R401.3 Drainage is the anchor provision for the whole chapter. It states that surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection that does not create a hazard; that lots shall be graded to drain surface water away from foundation walls; and that the grade shall fall a minimum of 6 inches (152 mm) within the first 10 feet (3 048 mm).
The exception matters as much as the rule. Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, drains or swales shall be constructed to ensure drainage away from the structure, and impervious surfaces within 10 feet of the building foundation shall be sloped a minimum of 2 percent away from the building. Side yards on tight subdivisions routinely trigger this exception, because the house is set close enough to the lot line that there is no room for a 5 percent slope.
The arithmetic you must be able to do cold
The 6-inch rule is a slope, not a magic distance. Six inches over ten feet is 0.5 ft divided by 10 ft, or 5 percent. Converting percent to inches per foot is just 0.01 x 12 inches:
| Slope | Fall per foot | Fall over 10 feet | Where it appears |
|---|---|---|---|
| 1% | 0.12 in | 1.2 in | Sample design slope |
| 2% | 0.24 in | 2.4 in | R401.3 impervious surfaces within 10 ft of foundation |
| 5% | 0.60 in | 6.0 in | R401.3 general grade away from foundation |
| 10% | 1.20 in | 12 in | Sample design slope |
Worked example 1. A 12-foot-wide concrete patio has a uniform 2-inch drop from house to yard. Its slope is 2 ÷ 144 ≈ 1.39 percent. Provide at least 2.4 inches of fall in the first 10 feet. If the revised slope is uniform across all 12 feet, exactly 2 percent takes 2.88 inches of total fall. An edge drain may receive that runoff, and the patio surface within 10 feet still needs the prescribed slope.
Worked example 2. A side yard is 8 feet wide and a fixed drainage easement elevation limits the available fall to 4.8 inches. That is 5 percent over 8 feet, but the general rule specifies 6 inches of fall. If the physical constraint prevents the full drop, use a drain or swale to convey runoff away from the foundation to the approved collection point.
Worked example 3. A sidewalk 5 feet wide with 1.5 inches of fall: 1.5 / 60 = 2.5 percent, which satisfies the 2 percent impervious-surface minimum.
Roof Drainage (R801.3)
Section R801.3 applies where expansive or collapsible soils are known to exist: the dwelling must have a controlled method of water disposal from roofs that collects and discharges roof drainage to the ground surface not less than 5 feet (1 524 mm) from foundation walls, or to an approved drainage system. Use the site’s documented soil conditions to decide whether this provision applies.
In practice, controlled roof drainage means gutters sized to the roof area, downspouts that do not dump at the wall, splash blocks or extenders that carry water 5 feet or more away or into a piped leader, and a discharge point that is downhill of the foundation. Michigan winters add two traps: a leader that discharges onto a walk creates an ice sheet, and a buried leader without fall or freeze protection becomes a split pipe in February. Use a separate roof-water path unless the approved drainage design specifically accommodates both flows. A direct connection can overload the foundation drain.
Foundation Drainage (R405.1)
Section R405.1 requires drains around concrete or masonry foundations that retain earth and enclose habitable or usable spaces located below grade. Drainage tiles, gravel or crushed stone drains, perforated pipe or other approved systems are installed at or below the area the drain protects and must discharge by gravity or mechanical means into an approved drainage system.
The gravel detail is testable: gravel or crushed stone drains must extend at least 1 foot beyond the outside edge of the footing and 6 inches above the top of the footing, and must be covered with an approved filter membrane material; the tops of open joints in drain tile are protected with strips of building paper. The filter fabric is not optional decoration. Without it, silt migrates into the stone and pipe, and the drain that was supposed to protect the basement becomes a clogged clay plug within a few seasons.
For perforated pipe or drain tile, R405.1 specifies at least 2 inches of washed gravel or crushed rock beneath it and at least 6 inches over it. The bedding aggregate must be at least one sieve size larger than the openings. Unless the manufacturer recommends otherwise, wrap an approved filter membrane around perforated drains or use it over the aggregate that covers the pipe. Follow the approved detail for pipe size, perforation orientation, slope, cleanouts and outlet. Verify the allowed connection with the sewer operator before routing any flow into a sewer.
R405.1 also carries an exception worth remembering for the exam: a drain is not required where the foundation is installed on well-drained ground or a qualifying sand-gravel mixture in USCS Group I under Table R405.1. Use the table and site evidence for the soil and drainage determination.
Sump Pumps and Mechanical Discharge
When gravity cannot reach a legal outlet, R405.1 permits discharge by mechanical means — the sump pump. A proper installation includes a rigid or semi-rigid pit liner, a pump sized to the inflow, a check valve so water does not drain back, a discharge line with fall and freeze protection, and a discharge point that is downhill and well away from the foundation. Discharging onto a flat lawn that slopes back to the wall simply recycles the water. Many communities also limit or prohibit sump discharge to the sanitary sewer, and some require it to go to grade, a dry well, or the storm system.
Dampproofing and Waterproofing
Drainage and waterproofing are partners, not substitutes. For concrete or masonry walls that retain earth and enclose interior spaces and floors below grade, R406.1 requires exterior dampproofing unless R406.2 requires waterproofing because a high water table or another severe soil-water condition is known. Both extend to finished grade from the higher of the footing top and the point 6 inches below the top of the basement floor. Check the applicable plumbing and local rules for drainage piping and connections.
Local Stormwater Ordinances
Part 91 controls erosion and sediment from earth changes, while applicable Part 31 authorizations regulate construction stormwater or other discharges. Local stormwater and sewer requirements can also affect where runoff or pumped water may go during and after construction. Many Michigan communities operate under NPDES municipal separate storm sewer (MS4) permits and adopt ordinances that add on-site retention, downspout disconnection, limits on sump and footing-drain connections to the storm sewer, and grading certificates at final inspection. A retention basin is defined in the Part 91 rules as an area constructed to capture surface runoff that does not discharge directly to a lake or stream through an outlet; water leaves by infiltration and evaporation. A detention basin stores water and releases it through a controlled outlet at a restricted rate. The distinction shows up on exams and on plan reviews.
Field Traps That Cost Real Money
- Backfill placed too wet and never compacted settles after landscaping, creating a reverse grade against the wall that no amount of topsoil fixes.
- Downspouts that direct concentrated flow back toward the footing or fail the R801.3 outlet requirement where it applies.
- A swale with a flat bottom that ponds instead of flowing, because the contractor graded to a visual line instead of a laser or level.
- Sump discharge piped into the footing drain, which pressurizes the drain and wets the basement it was built to protect.
- Confusing dampproofing with waterproofing and skipping the drainage layer on a site with a high water table.
The exam version of this section is almost always arithmetic plus one code sentence: compute the slope, compare it to 5 percent for grade and 2 percent for impervious surfaces, and remember that the exception requires a swale or drain rather than an excuse.
Quick Reference: Who Requires What
| Requirement | Code section | The number to remember |
|---|---|---|
| Grade away from foundation | 2015 MRC R401.3 | 6 in fall in first 10 ft (5%) |
| Impervious surface near foundation | 2015 MRC R401.3 exception | 2% minimum away from building |
| Roof water discharge | 2015 MRC R801.3 | Where expansive or collapsible soils are known, at least 5 ft from foundation walls if discharging to grade, or an approved system |
| Footing drain gravel envelope | 2015 MRC R405.1 | 1 ft beyond footing edge, 6 in above footing top, filter membrane |
| Footing drain discharge | 2015 MRC R405.1 | Gravity or mechanical, to approved drainage system |
| Dampproofing extent | 2015 MRC R406.1 | Finished grade down to the higher of the footing top or 6 in below the basement floor |
| Retention basin definition | Part 91 rules, R 323.1701(1)(j) | No direct outlet; infiltration and evaporation only |
A useful way to hold the two slope numbers together is to remember that the code's general grade is a structural-protection slope and the impervious-surface slope is a surface-protection slope. The general grade keeps bulk water away from the wall; the 2 percent keeps pavement, patios and walks from delivering water back to the wall through a seam or a joint. Check the finished earth grade, impervious surfaces and drainage structures at the same house.
If a physical barrier prevents the required fall for earth grade, use a drain or swale to convey water away. Keep the minimum 2 percent fall on any nearby impervious surface covered by R401.3. Document the decision on the plot plan and, where the community requires it, get the grading detail approved before the excavator arrives, because re-grading after landscaping is one of the most expensive change orders in residential construction.
A fixed outlet and a lot line prevent the side yard from falling 6 inches away from the foundation within the first 10 feet. Under 2015 MRC R401.3, what is required?
Nothing, because the 6-inch rule applies only to the front yard
A steeper grade that pushes water onto the adjoining lot
Drains or swales constructed to ensure drainage away from the structure
A variance from the Michigan Residential Code before final grade
Under 2015 MRC R405.1, how far must a gravel or crushed stone footing drain extend beyond the outside edge of the footing, and how high above the top of the footing?
At least 6 inches beyond the edge and 12 inches above the top of the footing
At least 1 foot beyond the edge and 6 inches above the top of the footing
At least 2 feet beyond the edge and level with the top of the footing
At least 18 inches beyond the edge and 3 inches above the top of the footing
Where expansive or collapsible soils are known to exist, 2015 MRC R801.3 requires roof drainage to be discharged in what manner?
To the ground surface not less than 5 feet from foundation walls, or to an approved drainage system
Directly into the footing drain so roof water and groundwater share one outlet
To the ground surface not less than 2 feet from foundation walls
Onto the driveway so it can flow to the street