45.2 Expansion & Control Joints

Key Takeaways

  • Fired clay brick generally grows with long-term moisture exposure. CMU generally contracts as it dries and carbonates. Temperature changes can affect both.

  • BIA recommends checking openings, corners, heights, backing changes and parapets before setting regular brick expansion-joint spacing. R703.8.2 requires a joint where frame-supported veneer meets foundation-supported veneer.

  • CMHA empirical CMU limits depend on panel proportions, nominal unit height and horizontal steel. An 8-inch-high unit with the stated reinforcement uses the lesser of 1.5 times panel height and 25 feet 4 inches.

  • Calculate movement from the installed condition. Compare opening and closing with the least capable joint component, including tolerance, and use two-sided sealant adhesion.

  • Follow the design for required lateral load transfer and structural reinforcement at CMU joints. Keep hard material out of brick expansion gaps and preserve the flashing and weep path.

Last updated: November 2026

Why Masonry Moves

Fired clay brick normally has long-term moisture expansion. Concrete masonry normally has long-term contraction from drying shrinkage and carbonation. Both also change dimensions as temperature changes. Restraint can convert movement into stress. For example, a veneer can grow against a frame or adjoining wall, and a CMU panel restrained at a foundation can crack as it shortens.

JointWhat it doesHow to detail the separation
Brick expansion jointPermits adjacent brickwork to expand toward the gapKeep the gap free of mortar and use the specified compressible materials and sealant
CMU control jointLocalizes shrinkage cracking at a plane of reduced restraintProvide the specified bond break and allow in-plane movement
Isolation jointPermits relative movement between assemblies or materialsMaintain the clearance or specified compressible joint at the interface

Crack-control reinforcement normally stops at a CMU control joint to avoid restraining the panel. Preserve reinforcement required for structural continuity and follow any engineered relief-joint detail. Some panels have independent lateral support. Where the design transfers out-of-plane load across the joint, use the specified load-transfer detail, such as keyed or sleeved connections that allow the required in-plane movement. Cutting a continuous structural bond beam to make a joint can change the load path.

Spacing and Location by Material

For clay brick veneer, BIA Technical Note 18A recommends limiting regular spacing to 25 feet for a wall without openings, with closer, often symmetric spacing of no more than 20 feet to consider for multiple openings. Determine actual spacing from movement, joint capacity, material transitions and the elevation. Check stress concentrations at offsets, openings, wall intersections and abrupt height or support changes. At a corner the BIA prefers a joint within 2 feet and recommends the first joint within about 10 feet on at least one side. The two distances measured along the walls from the corner to the first joints should add to no more than the straight-wall spacing. For a 25-foot design spacing, 10 feet on one side and 15 on the other illustrate that check.

Continue brick expansion joints through parapets and coordinate the coping detail. BIA recommends closer joints or wider joints if spacing at the top of the parapet exceeds 15 feet. At veneer supported by wood or cold-formed steel adjoining foundation-supported veneer, provide the movement joint required by 2015 MRC R703.8.2. These are different checks from regular spacing in the wall field.

For above-grade CMU, current CMHA empirical guidance in CMU-TEC-009-25 uses both a maximum panel length-to-height ratio of 1.5 and a spacing cap. For units of nominal 8-inch height the cap is 25 feet 4 inches with at least 0.025 square inch of equivalent horizontal reinforcement per vertical foot. For nominal 4-inch-high units or anchored concrete masonry veneer, the cap is 20 feet with at least 0.034 square inch per vertical foot. The criteria assume qualifying units and may need adjustment for local or project conditions. These are industry design recommendations. An engineered wall or wall with continuous reinforced relief joints follows its own design.

For a 9-foot-high wall of nominal 8-inch-high CMU with the required reinforcement, 1.5 × 9 = 13.5 feet. That governs over the 25-foot-4-inch ceiling. At openings or other stress concentrations, coordinate the joint location, reinforcement and load transfer with the design. Inspect the masonry drawings before using a spacing rule in a structural wall.

Sizing a Sealed Movement Joint

Size the joint for the estimated movement from the installed condition. Compare opening and closing separately with available extension and compression. Account for the least capable sealant, backing or filler and allow for construction tolerance. For an exposed vertical brick joint, BIA recommends a compatible ASTM C920 Grade NS, Use M sealant and a movement class that meets the design. BIA prefers at least Class 50 compressibility and identifies Class 25 as an alternative where adequate. Class 25 and Class 50 indicate tested movement of 25 and 50 percent in each direction. Use compatible backing or a bond breaker so the sealant adheres to the two side faces and can deform. Check depth, primer and adhesion under the product instructions. Michigan's ASTM C920 Type S or M, Grade NS, Class 25 requirement for chimney-cap sealants comes from Rule 547b for that application.

Worked Closure Check at a Joint Between Two Brick Panels

BIA TN 18 estimates unrestrained brickwork movement from the moisture, freezing and temperature terms multiplied by length. In this simplified example, the joint is between equal 25-foot panels that move symmetrically about their centers. The brick is installed at the cool reference, then warms by 80°F. Use an allowance of 0.0005 in./in. for remaining moisture expansion, 0.000004 in./in. per °F for thermal expansion, and negligible freezing expansion in the example.

The length from each panel center to the joint is 12.5 feet, or 150 inches. Each edge moves (0.0005 + 0.000004 × 80) × 150 = 0.123 inch into the joint, giving 0.246 inch of closure. If the entire assembly can compress by 50 percent of its installed width, the calculated minimum installed width for this closure is 0.246/0.50 = 0.492 inch. A half-inch opening would have only 0.004 inch of unused compression capacity under the assumptions. A 3/8-inch opening would provide only 0.1875 inch of compression travel. At a 25 percent effective compressibility, the calculated width is 0.984 inch before tolerance. Check the actual brick temperature at installation, subsequent cold opening, component movement limits and tolerances before specifying a nominal width.

Worked Layout for a 64-Foot Run

On a straight blank veneer wall with comparable exposure and support along its length, proposed joints at 0, 22, 44 and 64 feet give 22-, 22- and 20-foot panels. These pass the BIA 25-foot interval check for a wall without openings. Verify corner distances on adjoining elevations and check actual movement demand and joint dimensions before accepting the layout. A new opening, support change or offset can change the locations or spacing even when the original interval calculation passed.

Details at Shelf Angles, Lintels and Flashing

  • Provide the designed horizontal soft joint below a shelf angle. BIA shows a typical 1/4-inch minimum free gap or compressible material there, with larger gaps where calculated movement requires it. Account for brick growth, frame shortening, angle movement and deflection. Protect flashing from the supports and preserve weeps above the flashing.
  • Coordinate a vertical joint beside a loose lintel with the design. BIA details flashing above and below the angle as a slip plane, with a 1/8- to 1/4-inch space at each end. For that adjacent-joint detail, design for the weight of the full height of brick above the opening. Shifting the joint past the end of the lintel is another option. Follow the approved detail at a frame-mounted shelf angle.
  • At a roof or parapet, coordinate the designed joint with coping, step flashing and counterflashing. Maintain drainage continuity while providing the specified movement allowance. Remove mortar and shims that would bind the gap, and keep the drainage outlets open.

Mortar joints are separate from movement joints. In the R606.3.1 case the default bed and head joint thickness is 3/8 inch. For rain-exposed clay brick, BIA favors properly compacted concave, V or grapevine profiles. Tool the specified profile at thumbprint hardness. A movement joint uses the specified flexible seal and backing.

Test Your Knowledge

Which pairing matches a typical long-term masonry movement with a joint designed to accommodate it?

A

Fired clay brick tends to grow with moisture exposure, so a compressible expansion joint allows that growth

B

Clay brick shrinks as it dries, so clay masonry walls require control joints

C

Concrete masonry expands irreversibly, so concrete masonry walls require expansion joints

D

Both clay brick and concrete masonry shrink, so either joint type works in either material

Test Your Knowledge

Under CMHA CMU-TEC-009-25 empirical guidance, what is the maximum regular control-joint spacing for a 9-foot-high above-grade wall of nominal 8-inch-high units, with the specified 0.025 square inch of horizontal steel per vertical foot and no condition requiring a closer joint?

A

9 feet

B

25 feet 4 inches

C

20 feet

D

13 feet 6 inches