46.3 Roof Valleys

Key Takeaways

  • For an asphalt-shingle roof, install the valley lining before the shingles and follow the manufacturer’s instructions (R905.2.8.2).

  • An open metal valley must be lined with corrosion-resistant metal not less than 24 inches wide meeting Table R905.2.8.2 — such as 26-gage G-90 galvanized steel (0.0179 inch), 0.024-inch aluminum, 28-gage stainless steel, or 16-ounce copper (0.0216 inch nominal).

  • An open valley may instead be lined with two plies of mineral-surfaced roll roofing (ASTM D3909 or D6380 Class M): an 18-inch bottom layer and a top layer not less than 36 inches wide.

  • A closed valley (shingles across the valley) uses one ply of smooth roll roofing (ASTM D6380) at least 36 inches wide, or either open-valley lining, or self-adhering ASTM D1970 membrane permitted in lieu of the lining material.

  • Check the shingle manufacturer’s approved valley method and the detail where the valley meets the eave. Some products allow weaving and others limit the installation to open or closed-cut valleys.

Last updated: November 2026

A valley is the inside intersection of two sloping roof planes. Both planes deliver runoff to the intersection. Check how the valley will carry that concentrated flow and where it will discharge at the eave. R905.2.8.2 addresses valleys on asphalt-shingle roofs. Other coverings have their own details, such as R905.4.6 for metal roof shingles.

Open and Closed Valley Construction

  • In an open metal valley, the shingle cuts leave an exposed channel in a corrosion-resistant metal lining. Select a profile and clear opening suited to the tributary runoff, valley slope and selected shingle system. The code minimum width is for the full lining, including the portions that sit beneath the shingles.
  • An open valley with mineral-surfaced roll roofing carries water over the exposed upper ply. This option uses two specified plies, with the wider upper ply over the narrower lower one. At 36 and 18 inches, a centered upper ply reaches 9 inches past each lower-ply edge.
  • In a closed-cut valley, courses from one plane extend across the valley and the other plane’s shingles are trimmed as the manufacturer directs. In a woven valley, courses from both sides interlace across the center. Both have an underlying lining. Evaluate the selected shingle instructions before choosing the valley. GAF advises against weaving Timberline laminated shingles, while Owens Corning allows woven and metal alternatives for the Duration Series.

Lining Requirements Under R905.2.8.2

The section opens with the sequence rule — valley linings are installed per the manufacturer's instructions before applying shingles — then lists the permitted linings:

  1. Open valleys lined with metal: the lining must be not less than 24 inches wide and one of the corrosion-resistant metals in Table R905.2.8.2.
  2. Open valleys lined with roll roofing: use ASTM D3909 or ASTM D6380 Class M mineral-surfaced roll roofing, with an 18-inch bottom ply and at least 36 inches for the top ply.
  3. Closed valleys: one ply of smooth roll roofing (ASTM D6380) not less than 36 inches wide, or either open-valley lining from items 1 and 2 — and self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 is permitted in lieu of the lining material, a permitted closed-valley alternative.

Examples from Table R905.2.8.2 include: galvanized steel 26-gage, zinc-coated G-90 (0.0179 inch); aluminum 0.024 inch; stainless steel 28-gage; cold-rolled copper 16 oz/ft² (0.0216 inch nominal) or high-yield copper 12 oz (0.0162 inch), lead-coated versions of both; zinc alloy 0.027 inch; lead at 2½ lb; painted terne at 20 lb. The general flashing section, R903.2.1, sets the familiar floor elsewhere on the roof — corrosion-resistant metal not less than 0.019 inch (No. 26 galvanized sheet) — and the valley table has separate material-specific minima.

Comparison at a Glance

Valley typeLining required (R905.2.8.2)ApplicationWatch for
Open metalListed corrosion-resistant metal, ≥ 24 in. wideExposed metal channelCheck profile, fastening and interface with the shingle courses.
Open, roll-roofing linedMineral-surfaced roll roofing, 18 in. bottom and ≥ 36 in. topExposed mineral surfaceCheck ply order and the manufacturer’s lap and bonding detail.
Closed-cutOne ply smooth roll roofing ≥ 36 in. wide, or open-valley linings, or ASTM D1970 membrane in lieuWhere allowed for the selected shingleCut-back spacing off the manufacturer's dimension; missing edge treatment where required
WovenSame closed-valley liningsInterlaced courses where the chosen shingle system allows weavingCheck the manufacturer’s fastening clearance and shingle placement.

Treat eave ice barriers and valley linings as separate checks. R905.2.8.2(3) permits a qualifying ASTM D1970 membrane as a closed-valley lining. Some open metal valley specifications also call for a compatible membrane under the metal. Use the approved valley detail and connect it to the eave assembly.

Installation Sequence for a Valley

  1. Prepare the deck and eave detail. Confirm that the deck provides the intended support and the valley outlet sends water onto the designed drainage path.
  2. Lay the lining before the shingles. When the detail uses a self-adhered membrane, work from the low point up and integrate the laps with the eave barrier as the product instructions show. Where an open metal detail specifies a separate membrane, verify both layers and their compatibility.
  3. Coordinate the shingle courses and fasteners. Follow the selected detail for the cut lines, fastener clearance and fastening method. For a metal channel, keep fasteners out of the exposed drainage surface. Closed-cut instructions may require clipped corners, cement and a minimum distance from the center before fastening. Woven courses cross the center from both sides where approved.
  4. Check the outlet. Make sure the installed lower edge releases concentrated flow clear of the fascia and into the gutter where provided, without creating a reverse lap.

For example, Owens Corning’s Duration Series closed-cut detail uses a 36-inch liner, shingles extending at least 12 inches across the center from the first side and a fastener setback of at least 6 inches on each side. The second side is cut at the specified 2-inch offset. The detail calls for clipping and cementing those shingle corners. These are product instructions. The 24-inch code minimum for open valley metal answers a different question.

At inspection, compare the lining width, material, laps, fastener placement and eave termination against the approved detail. For reroofing, apply R908.5 to the condition of existing flashing and reconstruct flashing as required by R908.6 and the manufacturer’s instructions.

Exam Traps

  • Width mix-ups: open metal valley minimum is 24 inches wide; the open-valley roll-roofing plies are 18 inches below and at least 36 inches above. Closed-valley smooth roll roofing is at least 36 inches wide.
  • Ply order reversed: the 18-inch ply is the bottom layer, the wider ply is the top layer.
  • Sequence violation: lining installed after shingles contradicts the first sentence of R905.2.8.2.
  • Selection: verify whether the selected shingle manufacturer permits weaving. Product instructions can differ for two laminated shingles.
  • Omitting the required lining: closed valleys need an allowed lining. Where the manufacturer specifies a membrane layer, include it in the installed detail.
  • Code scope: use the asphalt-shingle valley table for the metal lining and R905.1.2 for the separate eave-barrier check.
Test Your Knowledge

An open metal valley is being lined on an asphalt-shingle roof. What does R905.2.8.2 require of the lining?

A

One ply of smooth roll roofing 18 inches wide

B

Galvanized steel at least 12 inches wide, of any gage available

C

Corrosion-resistant metal not less than 24 inches wide meeting Table R905.2.8.2, such as 26-gage G-90 galvanized steel

D

A woven shingle course with no lining beneath it

Test Your Knowledge

For a closed valley — one covered with shingles — which lining does R905.2.8.2 permit?

A

No lining at all, because the shingles themselves form the water barrier

B

Two plies of smooth roll roofing 12 inches wide

C

A single 18-inch layer of mineral-surfaced roll roofing

D

One ply of smooth roll roofing at least 36 inches wide — or either open-valley lining, or self-adhering ASTM D1970 membrane in lieu of the lining material

Sections you finish are checked off in the contents.