30.2 Wood Foundations & Columns
Key Takeaways
Chapter 44 references ANSI/AWC PWF-2015. R401.1 permits the Chapter 4 alternative for wood foundations where the building has no more than two floors and a roof and interior basement or foundation walls are no more than 50 ft apart. Check the separate seismic design rule.
PWF lumber and plywood must be pressure treated and dried after treatment per AWPA U1, Commodity Specification A, Use Category 4B, and field cuts must be treated with copper naphthenate containing at least 2 percent copper metal.
R402.1.1 requires Type 304 or 316 stainless steel for below-grade exterior plywood-to-framing fasteners and for knee-wall construction. R404.2.6 also directs panel fastening to Table R602.3(1).
Backfill against a wood foundation not designed to AWC PWF is limited to 4 feet, and no wood foundation wall may be backfilled until the basement floor and first floor are built or the wall is braced.
R407.3 specifies at least nominal 4 × 4 wood, or at least 3-inch Schedule 40 ASTM A53 Grade B steel pipe or approved equivalent. Provide bottom lateral restraint unless the short-column exception applies.
What a permanent wood foundation is
A permanent wood foundation (PWF) is a pressure-preservative-treated lumber and plywood wall designed to stay in the ground and enclose a basement or crawl space for the life of the house. A permanent assembly combines treated studs and sheathing, a designed footing, drainage and below-grade moisture protection.
The 2015 MRC does adopt wood foundations. Section R401.1 states that wood foundations shall be designed and installed in accordance with AWC PWF, which Chapter 44 identifies as ANSI/AWC PWF-2015. R401.1 allows use of the Chapter 4 wood-foundation provisions within the exception for buildings with no more than two floors and a roof and interior basement and foundation walls at intervals not exceeding 50 feet. In SDC D0, D1 and D2, accepted engineering practice is required.
Materials and fasteners
Three material rules separate a code-compliant PWF from treated lumber assembled on site:
- Treatment: all lumber and plywood must be pressure-preservative treated and dried after treatment in accordance with AWPA U1, Commodity Specification A, Use Category 4B and Section 5.2, and must bear the label of an accredited agency (R402.1.2).
- Field cuts: where wood is cut or drilled after treatment, the cut surface must be field treated with copper naphthenate containing at least 2 percent copper metal, brushed, dipped or soaked repeatedly until the wood stops absorbing preservative.
- Fasteners (R402.1.1): below grade, fasteners attaching plywood to the exterior side of basement or crawl space studs must be Type 304 or 316 stainless steel. Above grade you may use stainless, silicon bronze, copper, hot-dipped galvanized or hot-tumbled galvanized nails. The 304/316 requirement also applies to knee-wall construction. R402.1.1 disallows electro-galvanized nails and galvanized staples for this work. R404.2.6 also requires the applicable fastening schedule in Table R602.3(1). Check the approved standard for other connections.
Framing and sheathing
For the R404.2 details, use nominal 2 by 6 studs (R404.2.2). Spaced 16 inches on center, the species must have an Fb of at least 1,250 psi; spaced 12 inches on center, the minimum drops to 875 psi. R404.2.1 requires identified lumber and wood structural panels conforming to DOC PS 1 or PS 2. When fill exceeds 12 inches above the interior crawl grade or basement floor, size the plywood under R404.2.3 using its table and notes for the applicable height, spacing and face grain. As a reference point, a wall with 48 inches of fill and studs 16 inches on center, face grain across the studs, calls for 19/32-inch B-grade panels with a 40/20 span rating. The table assumes a 30-pcf equivalent fluid weight. Follow the table’s grade and orientation limits or the approved design for conditions outside its scope.
Footing, backfill and moisture details
A wood wall still needs a real footing. R403.2 requires washed, well-graded gravel with a maximum stone size of 3/4 inch when gravel is used. Crushed stone is limited to 1/2 inch. Sand must be coarse, with grains no smaller than 1/16 inch. Both gravel and sand must be free of organic, clayey and silty soils. Figures R403.1(2) and R403.1(3) show the basement and crawl space sections: treated footing plate, gravel bed, stud wall, sheathing and drainage layer.
Backfill height and sequence each govern the load on the wall. For wood foundations that are not designed and installed in accordance with AWC PWF, R404.2.3 caps backfill at 4 feet. R404.2.4 adds the sequencing rule: wood foundation walls may not be backfilled until the basement floor and first floor have been constructed or the walls have been braced. For crawl spaces, backfill or bracing is installed on the interior before exterior backfill goes on. Concrete and masonry walls have their own support conditions in R404.1.7. Keep the two sequences distinct.
Drainage and dampproofing are not add-ons for wood (R404.2.5). Under R405.2 the system is a porous layer at least 4 inches thick under the basement floor, a 6-mil polyethylene vapor retarder over that layer with the slab cast on top, and, in soils other than Group I, a sump at least 24 inches in diameter or 20 inches square that extends at least 24 inches below the bottom of the basement floor. Drain the footing and porous layer and provide positive gravity or mechanical drainage to daylight or an approved sewer. Under R406.3, plywood panel joints are sealed full length with caulking, and a 6-mil polyethylene membrane covers the below-grade exterior, lapped 6 inches and sealed, running down to the bottom of the wood footing plate but not overlapping into the gravel footing. Bond the top edge to the sheathing. The treated strip protecting the film extends from several inches above grade to about 9 inches below grade, with its joint caulked. Porous fill made from the footing material rises 1 foot above the footing on well-drained sites, or half the total backfill height on poorly drained sites, and is covered with 30-pound asphalt paper or 6-mil polyethylene to keep fines out while allowing seepage. Place the remaining backfill using the same soil type as was removed under R406.3.4.
Wood columns, posts and steel columns
Section R407 governs columns in basements, crawl spaces and under-floor areas:
- Wood columns must be protected against decay as required by R317. Minimum nominal size is 4 by 4 inches.
- Steel columns must be not less than 3-inch-diameter Schedule 40 pipe manufactured to ASTM A53 Grade B or an approved equivalent, and R407.2 generally requires rust-inhibitive shop coating on the inside and outside. Corrosion-resistant steel and steel with corrosion-resistant coatings are excepted from that shop coat requirement.
- Every column must be restrained against lateral displacement at the bottom end. The exception covers columns no more than 48 inches tall on a pier or footing, in Seismic Design Categories A, B or C, inside an under-floor area enclosed by a continuous foundation.
Column work on a real job is mostly load path and decay. A basement post carries a beam, so the post needs a bearing plate or approved post base, the beam must be connected to the post, and the post must bear on a footing sized for its tributary load — not a scrap of plywood on the slab. Use the approved column or listed equivalent for its specified loading and installation limits, including permitted extension if adjustable.
Sill plates belong in this conversation too. R404.3 requires wood sill plates to be at least 2 by 4 nominal and anchored under R403.1.6. Check the Michigan adoption exclusion for model R602.11 and the approved connection detail, and R403.1.6 requires sill and sole plates to be protected against decay and termites where R317 and R318 demand it. Check the sill location and exposure alongside the approved anchor layout.
Choosing and detailing a permanent wood foundation
A PWF needs compatible materials and a site drainage design. Verify bearing conditions, groundwater, restraint and the approved sequence before selecting the footing and wall system. Coordinate the sheathing and insulation with the dampproofing and drainage details before backfill.
Worked scenario
A builder proposes an 8-foot-tall PWF basement wall retaining 7 feet of unbalanced backfill, 16-inch stud spacing, and hot-dipped galvanized nails below grade. Check the proposed wall against three requirements:
- Backfill height. R404.2.3 allows 4 feet of backfill for walls not designed to AWC PWF. Seven feet requires a design and installation under AWC PWF-2015 for this wood-wall proposal.
- Fasteners. Below grade, plywood-to-stud fasteners must be Type 304 or 316 stainless steel. Hot-dipped galvanized is permitted above grade only.
- Sequence. Even with a proper design, the wall cannot be backfilled until the basement floor and first floor are built or bracing is installed (R404.2.4), and drainage, dampproofing and the grade strip must be complete before soil returns.
Traps to expect: untreated or lightly treated wood below grade is prohibited, not merely discouraged; a PWF is not exempt from footings, drainage or dampproofing; the specified plywood fasteners and knee-wall fasteners require the appropriate stainless type; and "pressure treated" on a lumber tag is not the same as "Use Category 4B" on a PWF label.
Which fasteners are required below grade where plywood sheathing is attached to the exterior side of permanent wood foundation studs?
Hot-dipped galvanized common nails
Electro-galvanized box nails
Type 304 or 316 stainless steel
Aluminum siding nails with neoprene washers
A wood foundation wall qualifies to use the R401.1 Chapter 4 alternative and is not designed and installed under AWC PWF-2015. What is the maximum height of backfill permitted against that wall?
2 feet
4 feet
6 feet
8 feet, matching the wall height