58.2 Barricades & Signs

Key Takeaways

  • Part 22 distinguishes immediate hazards (danger), potential hazards or unsafe practices (caution), and general safety instructions. Cover or remove accident-prevention signs when the hazard ends.

  • Use Rule 2230 Table 2 as a guide to minimum letter size at a safe viewing distance. At 100 feet, the table gives 3-inch letters.

  • In the 2011 MMUTCD, Type 1 and 2 barricades have one and two marked rails, respectively, with a 24-inch minimum rail length. A Type 3 has three marked rails, with a 48-inch minimum rail length, for closures.

  • Barricade rails use alternating retroreflective orange and white stripes sloped 45 degrees down in the direction of passage. Sandbags can ballast the lower frame or stays where permitted.

  • Apply the device and project rules for day and night. A channelizing device guides traffic. A crashworthy temporary barrier can provide positive protection when called for by the plan.

Last updated: November 2026

Accident-Prevention Signs, Tags and Road Devices

Michigan Part 22 governs construction signs, tags and barricades. Rules 2221 and 2224 apply to employee warnings and barriers, with Rule 2224 providing the off-public-right-of-way duty when a more specific standard does not apply. Roadway devices operate under the dated employee-protection rule in R 408.42223 and the applicable road agency requirements. The roadway examples below use Part 6 of the 2011 MMUTCD incorporated by Rule 2223. For installations under a road agency contract, check the specified edition, plan and supplement.

Accident-prevention signUpper panel or legendUsePart 22 rule
DangerWhite lettering in a red oval outlined in white, on a black upper panelImmediate hazard calling for special precautions2233
CautionYellow lettering on a black upper panelPotential hazard or unsafe practice2234
Safety instructionWhite lettering on a green upper panelGeneral safety instruction or suggestion2235
ExitRed letters at least 6 inches high on white, with a principal stroke of at least ¾ inchRequired indication of a discharge point2236
DirectionalBlack arrow on a danger, caution or safety instruction sign, or white arrow on black for a standalone safety directional signPoints out a safe direction2237

Rule 2230 uses message length, visibility and readability to determine letter size. Use Table 2 as a guide to minimum height at a safe viewing distance. Its example rows include 1 inch at 31–40 feet, 2 inches at 61–75 feet, 3 inches at 91–105 feet, 4 inches at 121–150 feet and 5 inches at 201–250 feet. For heights above 5 inches, Rule 2230 specifies an added inch for each additional 35 feet. Place signs where workers can read them in time to act and remove or cover them when the hazard ends under Rules 2229 and 2231.

Tags identify a specific hazard, such as a defective tool. The tag is a temporary alert under Rule 2241, at least 2⅜ inches by 4¾ inches with a bold signal word. Rule 2242 distinguishes Do Not Start, Danger, Caution, Out of Order and Do Not Operate. For a defective chop saw, warn employees with the appropriate tag, remove the saw from service, and use one of the ways Part 1 Rule 115 permits to prevent its use. A tag alone still leaves the saw available. Remove a tag when its reason has been eliminated.

TTC signs use regulatory, warning and guide categories. For example, ROAD CLOSED regulates access and an advance ROAD WORK sign warns of changed conditions. Place them under the traffic plan rather than using shop or site safety sign designs in the roadway.

Barricades and Positive Protection

Roadway barricadeMarked railsMinimum rail lengthTypical selection under 2011 §6F.68
Type 1One24 inchesConventional road or urban street with road user flow maintained
Type 2Two24 inchesMay be selected for a high-speed road when flow is maintained
Type 3Three48 inchesRecommended for closing or partially closing a road. Also an option in high-speed environments

The manual specifies rails 8–12 inches wide and alternating orange and white retroreflective stripes. Stripes are usually 6 inches wide, sloping down at 45 degrees in the direction road users will pass. Rails shorter than 36 inches may use 4-inch stripes. The required retroreflective area facing traffic on high-speed roads is at least 270 square inches. Where traffic may turn in both directions at a closure, the stripes should slope down from the center in each direction. Where no turn is intended, the guidance directs stripes downward toward the center.

Where ballast is needed, place approved sandbags low on the frame or stays, keeping rails visible and avoiding hard objects that pose a collision hazard. Check the device design and agency requirements. The barricade marks or channels traffic. A separately selected crashworthy temporary traffic barrier can protect a work space, and when used for channelization it also needs delineation.

Worked selection for a culvert closure

A road authority closes a two-lane highway to through traffic and allows access to homes from one approach up to the culvert. At the access-controlled closure, use Type 3 barricades arranged to preserve the authorized access, with the appropriate local-access sign legend. Drivers need to see the barricades from either direction. At the excavated segment no traffic can pass, so the closure arrangement can span the roadway as the plan requires. Verify how allowed local traffic turns or leaves instead of assuming every closure uses the same rail placement.

Choose and Maintain Channelizing Devices

Device2011 Part 6 features to verifyApplication
ConePredominantly orange, at least 18 inches for daytime low-speed use and at least 28 inches on high-speed roads, at night on highways or when additional conspicuity is neededUse retroreflection or lighting at night as specified. Larger cones may be required by the project. MDOT's work-zone manual uses at least 42 inches for cones at night on MDOT roadways
DrumLightweight deformable material, at least 36 inches high and 18 inches wide in any orientation, alternating retroreflective circumferential stripes and a closed topUse for visible delineation. Keep ballast off the top and avoid a hazardous setup if struck
Vertical panelRetroreflective striped face 8–12 inches wide and at least 24 inches high, with 45-degree stripesUse where lateral space is limited and verify the plan and mounting details

Under Michigan §6F.63, below a posted work-zone limit of 45 mph, the spacing guidance uses no more than one speed-limit unit in feet in a taper and twice that in a tangent. At 35 mph in that setting, this gives 35 feet and 70 feet. At 45 mph or higher, the Michigan guidance uses 50 feet in the taper and 100 feet in the tangent. A closer interval may follow from a particular layout, project detail or agency specification. Use the separate criteria for a one-lane, two-way taper. For pedestrian routing, use continuous detectable channelization when required. A line of discrete cones alone leaves gaps for a person using a long cane.

Before dark, confirm devices and signs remain visible and replace those that have lost significant retroreflectivity or effectiveness. The manual specifies dimmed arrow-board operation after dark. Use flashing warning lights to mark an isolated condition when the plan calls for those lights. Lights in a channelizing series are steady unless an allowed sequential flashing arrangement is used for a merging taper. Confirm work and regulator lighting, sight lines, and any agency-specific equipment. Protect employees placing or retrieving devices from a moving vehicle under Part 22 Rule 2225, such as by use of a seat and worn seat belt or another prescribed protection.

Test Your Knowledge

Under the 2011 MMUTCD, which device and sign arrangement fit a highway closed to through traffic for culvert replacement when the authority allows driveway access from one approach?

A

Type 3 barricades arranged for the authorized access, with the applicable local-access sign legend and visibility from both directions

B

A line of 18-inch cones with no access sign

C

Two Type 1 barricades on the shoulders with through traffic guided between them

D

A single vertical panel at the centerline without a closure sign

Test Your Knowledge

A 48-inch Type 3 barricade directs vehicles past a lane restriction. Which rail marking and ballast arrangement follows the 2011 MMUTCD guidance and requirements?

A

Sandbags on the lower frame, with 4-inch orange and white stripes sloped down in the direction of passage

B

Sandbags on the lower frame, with 6-inch stripes sloped down away from the permitted path

C

Sandbags on the lower frame or stays, with 6-inch orange and white retroreflective stripes sloped down at 45 degrees in the direction of passage

D

Sandbags on the lower frame, with 6-inch orange and white stripes sloped down at 30 degrees in the direction of passage

Sections you finish are checked off in the contents.