60.1 Ladders & Scaffolds
Key Takeaways
MIOSHA Construction Part 11 governs fixed and portable ladders. Part 12 governs scaffolds and scaffold platforms, with the scaffold guardrail specifications in Part 21.
Check the portable ladder’s duty rating against the combined weight of the worker, tools and materials. A 260-lb load exceeds a 250-lb Type I rating; an appropriate 300-lb Type IA ladder has the required load rating.
For a non-self-supporting portable ladder use approximately 4 units up for 1 out, following Rule 1124 and the model instructions. Upper-landing access requires 3 ft of side-rail projection or the prescribed rigid top securement and separate grasping device when the ladder is too short.
Rule 1124 limits where a worker stands on a portable ladder. Under Rule 1122, both shoulders outside one side rail is overreaching. Face the ladder, grasp it with at least one hand while climbing, and keep loads from interfering with balance.
The ordinary §1926.451(a)(1) capacity rule includes scaffold self-weight plus four times the maximum intended load. Under Michigan Rule 1213, the usual scaffold work-platform guardrail threshold is 10 ft or more. Check specific platform and fall-protection rules for the scaffold type.
Michigan Construction Part 11, Fixed and Portable Ladders, governs ladder selection and use. Part 12, Scaffolds and Scaffold Platforms, governs construction staging. Part 21 supplies Michigan scaffold guardrail specifications. Match the rule to what is carrying or protecting the worker.
Ladder types and duty ratings
Read the ladder model's marked duty rating. Part 11 Rule 1102a incorporates ANSI ladder standards, and Rule 1122(7) prohibits exceeding the ladder's capacity. These are common portable-ladder ratings:
| Type | Duty rating | Rated load | Typical service |
|---|---|---|---|
| III | Light duty | 200 lb | Household use |
| II | Medium duty | 225 lb | Commercial and light trades |
| I | Heavy duty | 250 lb | Industrial |
| IA | Extra-heavy duty | 300 lb | Industrial, frequent use |
| IAA | Special duty | 375 lb | Heavy industrial |
Count the worker, clothing, tools and material. A 205-lb carpenter with 35 lb of tools and 20 lb of material produces a 260-lb load. That exceeds a 250-lb rating. An appropriate 300-lb Type IA model can meet the load rating, but the worker still needs a way to raise the bundle without losing balance. When choosing an extension ladder for access, allow for the overlap of the sections and the required projection.
Setting up an extension ladder
- Pitch. Rule 1124(1) limits the base offset to one-quarter of the vertical rise to the top support. Rule 1124(13) also describes approximately one-quarter of the working length measured along the ladder. With a top support 24 ft up, about 6 ft out gives a ladder angle of about 76°. This example uses the rise to the support, not the nominal length printed on the ladder.
- Steep setups. If the offset is less than one-fifth of the vertical rise, secure the top to prevent backward tipping. At 80° or more, Rule 1124(4) requires compliance with the fixed-ladder requirements referenced in General Industry Part 2.
- Upper landing. Extend side rails at least 3 ft above the landing. Where ladder length prevents that extension, secure the top to a rigid support that will not deflect and provide a grasping device. Support both rails equally unless using a single-support attachment.
- Base and path. Use sound footing and suitable safety feet unless the ladder is tied, blocked or otherwise secured against displacement. Keep the top and bottom clear. Protect a ladder in a doorway, driveway or passageway with barricades or guards, or secure it against displacement.
- Sections. On a two-section extension ladder, the top section rests on the base section and is closest to the climber. Splice portable ladders only if they are designed for that use.
Climbing and working rules
Face the ladder and grasp it with at least one hand while climbing. Rule 1122 prohibits carrying a load that can cause a loss of balance. A tool belt or a separate means of lifting material can keep both hands available. Move the ladder when work would put both shoulders outside the same rail. Avoid pushing or pulling that can move or overturn it.
Rule 1124(10) prohibits standing on the top two rungs or within 3 ft of the top of a portable ladder. Rule 1126 adds stepladder provisions: open fully and lock the spreaders. Use the back only when the design permits climbing there. The rule prohibits standing on the top step or cap unless the stepladder is equipped with a handrail. Follow the type-specific rule and the model's standing-level label. Do not use a conventional stepladder as a straight ladder. Do not shift, extend or move an occupied ladder. Single-rail ladders are prohibited. Provide a ladder at an access point with a rise of at least 19 in. when none of the alternate access means in Rule 1113 is provided.
Electricity, inspection, and training
Under Rule 1124(6), do not use a manufactured portable metal ladder for electrical work or where the employee or ladder may contact electrical conductors. Use nonconductive rails where contact with exposed energized equipment is possible, subject to the separate Part 16 provisions. Rule 1124(7) also requires a 20-ft minimum from power transmission or distribution lines to use or move a metal ladder. The rule treats lines or apparatus as energized unless confirmed deenergized and visibly grounded. Where deenergizing is impractical, apply the applicable Table 1 clearance to the closest part of the ladder, worker or material. Table 1 sets 10 ft through 50 kV and a voltage-dependent clearance above 50 kV. Apply every relevant restriction.
Inspect ladders before use and after a fall or accident. For defects listed in Rule 1121(3), such as split rails, missing rungs or damaged locks, immediately tag and withdraw the ladder. Follow the separate withdrawal and repair provisions for defective fixed ladders. Rule 1112 requires training from a competent person on the ladder hazards, correct use, capacity and applicable rules, and retraining as necessary.
Check both dimensions: A 24-ft rise and 6-ft offset address pitch. A ladder that stops at the eave still needs the required upper-landing handhold and securement.
Scaffold types
| Scaffold | How it works | Typical residential use |
|---|---|---|
| Frame (tubular welded) | Prefabricated end frames stacked with cross braces, on base plates and mudsills | Siding, painting, masonry |
| System (modular) | Aluminum or steel standards, ledgers, and decks configured to the building | Complex facades, multi-level work |
| Rolling (mobile) | Frame or system tower on casters | Interior finishing, warehouse work |
| Suspended (two-point adjustable) | Platform hung from outrigger beams by wire ropes and hoists | High-rise facade and window work |
| Ladder jack | Planks carried by jacks hooked on two ladders | Gable ends and soffit work |
| Roof bracket | Brackets attached to the roof carry planks | Roofing and eave work |
| Pump jack | Brackets ride a vertical pole | Tall single-wall work |
Capacity and duty rating
Under adopted §1926.451(a)(1), most scaffold components must support their own weight and at least four times the maximum intended load applied or transmitted to them without failing. A qualified person designs the scaffold. Load it within its design and rating. Suspension ropes and connecting hardware have separate provisions, including a sixfold requirement and the adjustable-hoist load conditions in §1926.451(a)(3)–(4) and Rule 1212. Part 12's tube-and-coupler table and Subpart L Appendix A include these uniform-load ratings:
| Duty rating | Uniform load |
|---|---|
| Light duty | 25 psf |
| Medium duty | 50 psf |
| Heavy duty | 75 psf |
For this exercise assume the 6-ft by 8-ft platform is rated at a uniform 25 psf with no lower assembly limit. The 48-ft² working area permits 1,200 lb distributed over the platform. Forty 80-lb shingle bundles weigh 3,200 lb before workers or tools, so the proposed load fails. Spreading the bundles can change the local bearing and load distribution. It cannot lower their total weight.
Planking and platforms in Michigan
Rule 1217 governs working platforms. For wood planks, use scaffold-grade lumber with at least 1,500 psi fiber stress, not less than 2 by 10 in., with at least two planks side by side. Use the rule's span table for full-thickness versus nominal-thickness material, load and span. Fit edges tightly and deck working platforms fully where practicable. Adopted §1926.451(b)(1) generally limits gaps to 1 in. unless a wider gap is shown necessary; the remaining gap at uprights must then be no more than 9½ in. Follow the narrow scope of the exceptions for walkways and erection or dismantling.
Extend planks 6 to 12 in. past end bearers under Rule 1217, secure them against displacement and verify bearing and a minimum 12-in. overlap where lapped on bearers. A single-width manufactured pick has a 14-in. state minimum, with a 12-in. ladder-jack allowance. Also check the adopted platform-width requirements and the specific scaffold design. Do not bridge ladder jack platforms.
Guardrails and falling objects
Under Rule 1213(1), protect open sides and ends of a scaffold work platform 10 ft or more above the floor or ground with guardrails, subject to the rule's specific provisions. For a boatswain's chair, catenary, float, ladder jack or needle-beam scaffold, Rule 1213(2) calls for personal fall arrest. A single- or two-point adjustable suspension scaffold requires both a guardrail system and personal fall arrest under Rule 1213(2). Check the specific scaffold rules and any permitted guardrail configuration.
The Michigan scaffold guardrail in Part 21 Rule 2150 ordinarily has a top rail 38 to 45 in. high with an intermediate rail halfway down. It must resist a 200-lb side thrust at the top rail, with supporting posts at most 8 ft apart, closer for additional loads. Check Rule 1213(5) before counting a cross brace as part of the rail system. For example, a brace pivot at 40 in. needs a midrail halfway between the platform and pivot. A pivot below 18 in. or above 48 in. requires both rails. Access by the cross brace is prohibited even where it serves a guardrail function.
When exposed to falling objects, use the protection appropriate to the hazard under §1926.451(h), such as a barricaded exclusion area below or a system to prevent or catch falling objects. Where used, the scaffold toeboard must be at least 3½ in. high, have no more than ¼ in. of bottom clearance and withstand 50 lb in the specified directions. Add screening or other suitable protection where stacked tools or material could pass over the board.
Foundation, ties, and access
- Bases. Use base plates with mudsills or equivalent support on a sound, rigid footing. Rule 1210(2) limits leveling jack screw extension to 18 in. below the base. Keep unstable objects out from beneath the supports. Mobile scaffolds have a separate 12-in. adjusting screw limit.
- Ties. Stabilize a supported scaffold whose height is more than four times its base width. Follow the manufacturer or use the §1926.451(c)(1) tie pattern near the 4:1 height. Under that pattern tie at each end and at most every 30 ft horizontally, and repeat vertically at most every 20 ft for scaffolds 3 ft wide or less and every 26 ft for wider scaffolds. The top tie must be no farther down than the 4:1 height. Account for eccentric loads that can tip the scaffold.
- Access. Use Rule 1211 and §1926.451(e). A floor or landing more than 2 ft from the scaffold platform in elevation needs a compliant means of access. Direct step-across access is limited to 14 in. horizontally and 24 in. vertically. Use hook-on ladders designed for the scaffold or another approved method. Certain compatible welded-frame horizontal members qualify if all Rule 1211 conditions are met, including 11½-in. length, 18-in. maximum spacing, 300-lb midpoint strength and one user at a time. Cross braces never serve as access.
Moving scaffolds, weather, power lines, and the competent person
Michigan Rule 1241 restricts occupied movement. Among its conditions are a clear surface within 3° of level, a base dimension at least half the height, resilient caster tires, secured or removed tools and material, guardrails on all sides and advance warning to riders. Apply the applicable adopted mobile-scaffold movement requirements and equipment instructions as well. Lock casters as required while working. Moving a scaffold with everyone off is often the simplest way to avoid exposing workers during relocation.
Rule 1212 prohibits work in storms or high winds unless a competent person determines the work is safe and employees use personal fall arrest. Check both that rule and the applicable energized-line clearances under §1926.451(f)(6), accounting for insulation, voltage and the closest point of contact. Stay at least 10 ft from uninsulated energized lines, with larger clearances where required. Rule 1212(5) requires consulting the utility or property owner before erection within 10 ft and applying its other conditions. Consultation alone does not authorize a closer setup.
Have a competent person inspect before each shift and after events that could affect structural integrity. During supported-scaffold erection or dismantling, the competent person evaluates the feasibility and safety of access and fall protection. Under §1926.454, a qualified person trains users on the hazards, and a competent person trains workers performing the listed scaffold operations such as erecting, dismantling, moving, operating, repairing, maintaining or inspecting.
Scaffold checklist
| Check | Where to look |
|---|---|
| Sound base and leveling screws within allowed extension | Rules 1210 and 1241 |
| Capacity for workers, tools and material; tipping control | §1926.451(a), (c) and (f) |
| Plank grade, support, span, securement and permitted gaps | Rule 1217 and §1926.451(b) |
| Guardrails, personal fall arrest and falling objects | Rule 1213, Rule 2150 and §1926.451(h) |
| Proper access, electrical clearance and field inspection | Rules 1211–1212 and §1926.451(e)–(f) |
An extension ladder will serve an upper landing. Its top support is 24 ft vertically above the base. At the 4-up-to-1-out setup, what is the approximate horizontal offset?
4 ft
6 ft
8 ft
12 ft
A 6-ft by 8-ft scaffold platform is rated 25 psf for a uniform working load. Can it hold 40 shingle bundles weighing 80 lb each?
Yes. A 25-psf rating permits 3,200 lb on any platform
Yes, if all bundles are spread evenly
No. The platform allows 1,200 lb, and the bundles alone weigh 3,200 lb
No, but only when someone steps onto the scaffold
Which access practice is prohibited on a supported frame scaffold?
Climbing the cross braces to reach the next platform level
Using a hook-on ladder designed for that scaffold
Using a scaffold stair tower
Stepping onto the platform from an adjacent structure 10 in away horizontally and 12 in vertically
Sections you finish are checked off in the contents.