35.3 Fastening Schedules

Key Takeaways

  • Table R602.3(1) lists wood-framing fasteners by connection. R602.3 governs the exterior walls and R502.9 and R802.2 direct floor and roof-ceiling framing to the main schedule.

  • Sole plate to joist or blocking is 16d common at 16 inches on center face nailed (16d box at 12 inches); at a braced wall panel it becomes 2-16d common each 16 inches.

  • Top-plate corner and intersection laps use the count and direction specified in item 17, such as two 16d common face nails.

  • Match the listed nail type, diameter, length and pattern. Equal length or a comparison of shank areas cannot establish an approved substitution.

  • Rim joist or blocking to sill or top plate is 8d common at 6 inches on center, or 8d box at 4 inches on center when the smaller-shank nail is used.

Last updated: November 2026

One Table, Dozens of Connections

Table R602.3(1) lists wood framing fasteners. R602.3 directs exterior-wall framing to the applicable fastening tables, and R502.9 and R802.2 direct floor and roof-ceiling framing to the main schedule. Find the actual numbered item for the connection. Read the fastener type, dimensions, count, spacing, and driving direction as one detail.

The same nominal penny size can have different diameters. These examples use the lengths and shanks listed in the schedule.

NailLengthShank diameterTypical use
8d common2-1/2"0.131"joist to sill or girder; rim to plate
8d box2-1/2"0.113"joist-to-sill toenails or rim-to-plate nails at 4 inches on center
10d common3"0.148"rafter to plate; thick sheathing in item 32
10d box3"0.128"top plate to top plate; bridging
16d common3-1/2"0.162"sole plate to joist; top plate laps
16d box3-1/2"0.135"studs at braced wall panels
20d common4"0.192"built-up girders and beams

A 0.162-inch 16d common has 1.44 times the circular steel area of a 0.135-inch 16d box because area varies with diameter squared. That comparison cannot establish nail capacity or authorize substitution. Use the schedule’s tested or prescribed combination of count, shank size, length, spacing and joint geometry.

The table’s notes specify smooth common, box or deformed shanks unless a row says otherwise. The listed minimum average bending yields are 100 ksi at 0.142 inch or less, 90 ksi above 0.142 through 0.177 inch, and 80 ksi for the 0.192-inch shank. Use the stated staple gauge and crown where a staple is listed. Nail spacing is at most 6 inches at all supports where panel spans reach 48 inches. For the roof panel rows marked (f), use 6-inch nailing at gable end framing through 130 mph ultimate wind speed. Above 130 mph, use 4 inches at gable end wall framing and 6 inches at intermediate supports in zones extending at least 48 inches from ridges, eaves and gable end walls. Note (h) explains which panel edges use the edge schedule. Check the applicable uplift, bracing and wind-design limits separately.

The Connections You Will Be Tested On

Code itemConnectionFastenerSpacing / location
21Joist to sill, top plate or girder3-8d common (or 4-8d box)Toe nail, each joist
22Rim joist, band joist or blocking to sill or top plate8d common, 10d box or 3-in. by 0.131-in. nails; or 8d boxToe nail at 6" o.c. for the first three options or 4" o.c. with 8d box
14Sole plate to joist, rim, band or blocking — not at a braced wall panel16d common (16d box)16" o.c. face nail (12" with 16d box)
15Same, at a braced wall panel2-16d common (3-16d box)Each 16" o.c., face nail
12Top plate to top plate16d common (10d box)16" o.c. face nail (12" with 10d box)
17Top plates, laps at corners and intersections2-16d common (3-10d box)Face nail
16Top or bottom plate to stud4-8d box toe nail, or 3-16d box end nail (2-16d common)Toe nail or end nail
8Stud to stud, not at a braced wall panel16d common (10d box)24" o.c. face nail (16" with 10d box)
9Stud to stud and abutting intersection studs at braced wall panels16d box, or 16d common12" o.c. face nail (16" with 16d common)
11Continuous header to stud4-8d common (5-8d box)Toe nail
6Rafter or roof truss to plate, subject to the uplift detail3-10d common or 3-16d boxToe nail 2 on one side and 1 opposite. Check note (i) for a rafter attached to a parallel ceiling joist.
2Ceiling joist to top plate3-8d common (4-8d box)Toe nail, per joist
26Band or rim joist to joist3-16d commonEnd nail
29Bridging to joist2-10d (3 in. by 0.128 in.)Each end, toe nail
28Ledger strip supporting joists or rafters3-16d common (4-16d box)At each joist, face nail
27Built-up girders and beams, 2-inch layers20d common32" o.c. top and bottom, staggered; 2-20d at ends and splices
30Subfloor 3/8" to 1/2" to joists6d common6" at panel edges, 12" at intermediate supports
30Roof sheathing 3/8" to 1/2"8d commonBase row is 6" at supported panel edges and 12" at intermediate supports. Check roof note (f).

These rows show selected options. Item 15 uses a nail count at each 16-inch interval for the braced-wall bottom plate. Item 17 specifies the nail count at a corner or intersection lap. Item 13 addresses the separate double-plate butt-splice fastening and lap length. When a connection has additional uplift, bracing or product requirements, check those before using the general row.

Worked Fastener Counts

Example 1 — rim joist. At 26 feet, the run is 312 inches. With a nail at each end of an idealized 312-inch layout, the 6-inch common-nail option gives 52 spaces and 53 nails. The 4-inch box-nail option gives 78 spaces and 79 nails, about 49 percent more. These are takeoff counts. Lay out actual end clearances and connections before placing nails.

Example 2 — top plates. For a 32-foot run, the regular item 12 spacing of 16 inches gives 384 / 16 = 24 spaces, or 25 nails in an idealized layout including both ends. Price the joint details separately. The end joints in the two plates must be offset by at least 24 inches. In the item 13 case that includes Seismic Design Category A, use eight 16d common face nails on each side of the end joint and at least a 24-inch lap on each side if using that fastener option. Corner and intersection laps use item 17.

Example 3 — subfloor. Assume an interior 4-by-8-foot, 23/32-inch wood structural subfloor panel across joists at 16 inches on center. The two 4-foot ends are supported. The tongue-and-groove long joints have no separate blocking in this detail. For item 31 with 8d common nails, the supported ends use 6-inch maximum spacing, so estimate nine per end. Each of five interior joist lines takes five at 12-inch maximum spacing across 4 feet. That gives 18 + 25 = 43 nails before waste, with positions adjusted for the specified edge clearances. Perimeter support, blocked edges and a different joist layout can change the count.

Screws, Bolts and Substitutions

A screw substitution needs a code provision, an approved evaluation or a designed and approved assembly covering that specific use. For example, R507.5.1 permits at least three No. 10 by 3-inch wood screws per joist end where the deck rim supplies lateral restraint. Table R507.2 separately provides 1/2-inch lag-screw and bolt rows for qualifying ledgers.

A joist hanger uses the fastener sizes, lengths and holes in its instructions. The Simpson Strong-Tie LUS series, for example, has listed connector-screw options for specific models and applications. Ordinary drywall or general-purpose deck screws have no authorization based on nominal length alone.

Table R602.3(2) lists alternate assemblies with their own fastener dimensions and spacing. In the sheathing group up to 1/2 inch, a listed option is a 15-gauge, 1-3/4-inch staple at up to 4 inches along supported edges and 8 inches at intermediate supports, subject to the table’s footnotes. Check the separate underlayment group and any roof wind conditions.

What an Inspector Checks

  1. Fastener identity. Shank diameter is the tell. A 16d box and a 16d common are the same length and look alike in a pouch, but the 0.162-inch common has 44 percent more circular shank area than the 0.135-inch box. Verify the specified dimensions and fastener markings.
  2. Count per connection. Read the nail count and spacing together. Use the per-joint count at a lap and the count per 16-inch interval at a braced-wall sole plate.
  3. Spacing location. Six inches at panel edges and twelve inches at intermediate supports are different requirements in the same row; a roof or floor that is nailed at 12 inches everywhere fails the edge requirement.
  4. Flush driving. Check for overdriven nails and fasteners that miss framing. Correct the installation by the applicable panel or approved repair detail.
  5. Braced wall panel nailing. Panel nailing at braced wall lines is governed by R602.10, covered in a later chapter, but the sole-plate and stud rows in this table are part of the same system and are inspected together.
  6. Corrosion protection. Apply R317.3.1 to fasteners and connectors in preservative-treated wood, including listed materials and exceptions. R507.2.3 separately requires hot-dipped galvanized or stainless steel for the prescriptive deck ledger fasteners.
Test Your Knowledge

Per Table R602.3(1), how is a sole (bottom) plate fastened to the joists or blocking below it, away from braced wall panels?

A

3-8d common toenails at each joist

B

8d common at 6 inches on center, toe nailed

C

16d common at 16 inches on center, face nailed

D

2-16d common at 12 inches on center, end nailed

Test Your Knowledge

Which listed fastening pattern may be used where double top plates lap at a corner or an intersecting wall?

A

8d common at 24 inches on center

B

16d common at 16 inches on center, the same as a top-plate-to-top-plate joint

C

4-8d box toenails

D

2-16d common face nails, or 3-10d box

Test Your Knowledge

A framer wants to use 8d box nails instead of 8d common nails to fasten rim joists to the top plate. What does Table R602.3(1) require?

A

Tighten the spacing to 4 inches on center instead of 6 inches

B

Double the number of nails but keep 6-inch spacing

C

Add construction adhesive and keep 6-inch spacing

D

Nothing — box and common nails are interchangeable at the same spacing