16.3 Decommissioning, Selective Deconstruction & Adaptive Reuse
Key Takeaways
Use condition, mission, cost and material recovery information to compare options.
Evaluate proposed occupancy under applicable local code and accessibility regulations.
For demolition, confirm written engineering survey evidence, utility controls and applicable material-specific requirements.
Document salvage, recycling and regulated disposal under the project’s applicable requirements.
Decide what can remain in service
Owners may reconsider an asset when operations change, repairs accumulate, service costs become difficult to justify, or the property is needed for a different purpose. Compare the useful systems that can remain, the cost and effect of required alterations, and the consequences of relocation. Include interim operations, lease constraints and hazardous-material information where relevant. For example, a warehouse could serve a new owner with limited upgrades, support conversion to a new use after code review, or prove impractical to retain. Test structural condition, service capacity and owner requirements before selecting a path.
Renovation upgrades an existing facility to meet the project’s needs. Adaptive reuse repurposes all or part of a building for a different use. Keeping serviceable components can reduce waste and the need for new materials. Evaluate the project’s proposed use and whether a code change of occupancy applies, including changes that affect code requirements. For example, under a locally adopted 2024 IEBC, Chapter 10 addresses change of occupancy under the work area method, and Chapter 13 provides a performance compliance method where permissible. Check fire protection, exit capacity and structure under the adopted method with the authority having jurisdiction. For covered alterations, assess the applicable 2010 ADA Standards §§ 202.3–202.5 and regulations. Historic age alone gives no exemption. Qualified historic properties may qualify for limited exceptions according to the stated criteria.
Plan for salvage and disposal
If removal is necessary, compare selective deconstruction for components worth salvaging with recycling and disposal of the remaining material. Evaluate sequence, access, protection, market, storage, and which items the owner wants to retain. Specify how to tag and deliver the owner’s salvaged hardware, for example, and identify who documents recovered quantities. EPA identifies source reduction, reuse and recycling as strategies for managing construction and demolition materials. Concrete may be accepted as aggregate feedstock, while local processors determine whether they can accept products such as gypsum or mixed materials.
For a DoD example, UFGS 02 41 00 coordinates demolition and deconstruction with UFGS 01 74 19 for waste management. Coordinate project-specific requirements for demolition limits, protection of retained work, salvage ownership, separation, transport and tracking. If the contract sets a diversion goal, specify the measure, excluded streams, proof of destination and who reports it. Record separate regulated waste as required. A sample closeout record can show the measured quantity, material category, recovery facility, date and supporting receipt. Reconcile it with the diversion calculation so handled material is counted once and rejected loads are documented accurately.
Confirm prerequisites and close the property records
- Personnel and utilities. Under 29 CFR § 1926.850, before employees start demolition the employer must have written evidence of a competent person’s engineering survey. Notify affected utility companies in advance and shut off, cap or otherwise control services outside the building line before demolition. If a service must continue during demolition, relocate it as necessary and protect it. Where hazardous substances in equipment or piping are apparent or suspected, the standard requires testing, purging and hazard elimination before demolition.
- Asbestos. For a covered facility, 40 CFR § 61.145 requires a thorough asbestos inspection before demolition or renovation. Notification and removal requirements depend on the activity, material and amount. For example, on a non-emergency demolition subject to § 61.145(a)(1), the required notification precedes disturbance under § 61.145(b)(3)(i), and applicable regulated asbestos-containing material must be removed before activities would disturb it or preclude access, subject to the listed exceptions. Verify additional state or local requirements and applicable OSHA worker protection.
- Other materials. Identify separate obligations for each waste stream. Equipment such as chillers that is typically dismantled on site requires refrigerant recovery under EPA’s Section 608 rules before disposal. PCB ballasts, lead coatings, mercury lamps and tanks can require different handling, worker protection, disposal or closure measures. Determine applicability before disturbing them.
Assign responsibility for permits and notifications, isolating the site, preserving retained facilities and delivering closeout evidence. Preserve the records that apply to the project, such as the engineering survey evidence, utility confirmations, required waste documentation and final site condition. Put any continuing monitoring, site restrictions or retained utility obligations into the owner’s property records.
References ICC 2024 IEBC, DOJ 2010 ADA Standards, EPA materials recovery guidance, DoD UFGS 02 41 00, OSHA demolition preparatory operations, 40 CFR § 61.145, and EPA Section 608 disposal requirements.
A municipality proposes to adapt a warehouse for an entirely new public use. The existing frame will remain. What should the project team review before selecting the scope?
An automatic ADA exemption due to the age of the building.
The applicable existing-building change-of-occupancy provisions and accessibility requirements.
A mandatory removal rule for all reused building frames.
The construction waste diversion target as a substitute for code review.
Employees will demolish a hospital subject to the asbestos NESHAP. The affected facility has regulated asbestos insulation and a chiller to be dismantled on site. What should the preparation cover?
Proceed to demolition, then identify material and safety requirements at the disposal facility.
Use the engineer’s structural survey to replace all asbestos and refrigerant requirements.
Document the engineering survey and utility controls, meet applicable asbestos inspection, notice and removal rules, and arrange refrigerant recovery before disposal.
Begin after receiving a change-of-occupancy approval and defer equipment checks until demolition has finished.
Sections you finish are checked off in the contents.
You've completed this section
Continue exploring other exams