7.2 Four Methods of Specifying

Key Takeaways

  • Descriptive requirements prescribe properties or materials. Performance requirements state the results and how compliance will be demonstrated.

  • A standard can offer multiple grades, types, and options. Select the applicable ones and establish the governing edition.

  • An open proprietary requirement allows equivalents under stated criteria and procedures. A closed requirement limits acceptable products.

  • Specification style affects the choices available to others. Contract terms and applicable law determine responsibility.

Last updated: November 2026

Four ways to state a construction requirement

Descriptive, performance, reference standard, and proprietary are the four methods of specifying recognized by CSI. An individual requirement has a purpose even when the section uses several methods. For an exterior wall, the specifier may describe a flashing profile, state allowable water entry in a defined test, cite a product standard, and list a basis-of-design component and the criteria for equivalents. The assembly must satisfy the requirements that apply to it.

MethodWhat the requirement tells the readerWhat to verify before issue
DescriptiveWhich properties, dimensions, composition, or procedures are requiredPrescribed details are buildable, coordinated, and sufficiently complete
PerformanceWhat measurable result the assembly must achieveConditions, threshold, verification method, timing, and responsible party
Reference standardWhich published criterion or test appliesRelevant edition and provisions, including selections such as class or grade
ProprietaryWhich named products may be used or serve as a basis for comparisonProcurement authority, availability, equality criteria, and review procedure

Descriptive and performance requirements

A descriptive requirement can prescribe a metal sill profile, thickness, and finish using generic language. It gives bidders the same details to price. Check compatibility, interfaces, and dimensional tolerances before issuing it. A generic description can still limit competition if its details unnecessarily exclude workable products.

In United States v. Spearin (1918), the U.S. Supreme Court recognized an implied warranty concerning government-prescribed requirements when a contractor followed the government design and its defect caused the problem. Identify who furnished the design, what was actually prescribed, whether the contractor complied, and what caused the failure. An inadequate method selected by the contractor presents a different question. The case does not itself assign liability to a project’s architect or engineer or decide a state-law dispute.

A performance requirement gives bidders a measurable result they can achieve through acceptable solutions. For example, for a specified partition acoustic target, identify the applicable assembly and test method, including whether acceptance concerns a laboratory result or field performance. State what evidence is required and when. Check related limits such as assembly thickness and penetrations so one compliant result does not create a conflict elsewhere.

Delegated design requires its own allocation of responsibilities. Under AIA A201–2017 § 3.12.10, a contractor is generally not required to provide professional design services unless the documents specifically require them for part of the work or the contractor needs them for its means and methods. When the contract specifically delegates a design, identify performance and design criteria and use the applicable professional qualifications and submittal procedures. A performance statement by itself does not make that delegation.

Reference standards

An adopted reference standard can supply a test method, product criteria, an installation procedure, or a combination. Read the cited provisions for scope, applicability, and choices before writing the requirement. Select the grade, finish, class, or type where the project needs one. Establish the applicable edition from the specification and its reference-date rule, and account for standards and editions required by the adopted code.

For example, the U.S. Department of Defense guide specification for miscellaneous cast-in-place concrete offers several ASTM C150/C150M portland cement types, including I and V, for a designer to select. The guide specification is an editing starting point. If the project requires Type V, identify it in the project documents and coordinate other concrete performance requirements. Citing the standard title alone does not communicate the selection.

Proprietary requirements, equals, and substitutions

A closed proprietary specification restricts eligibility to specified products. An open proprietary specification identifies a product and provides a means to propose an equivalent. For a federal procurement governed by FAR 11.104, a brand-name-or-equal description identifies the salient physical, functional, or performance characteristics an equal must meet. FAR 11.105 establishes separate requirements for restricting a procurement to one manufacturer’s product or feature. Check the rules of the actual procurement when it is state, local, or private.

For an equipment replacement, identify capacity at stated conditions, utility connections, limits on installed size, and the control interface the owner actually needs. Use those requirements to compare offered equals. Specify how and when evidence is submitted. Distinguish a bid-time equal or substitution request under the solicitation from a request during construction. For an unmodified AIA A201–2017 § 3.4.2 project, substitutions generally require owner consent after architect evaluation and a Change Order or Construction Change Directive, subject to the minor-change exceptions in §§ 3.12.8 and 7.4.

References CSI specifying methods, United States v. Spearin, 248 U.S. 132, AIA A201–2017 §§ 3.4.2, 3.12.10, UFGS 03 30 53 § 2.2.1.1, FAR 11.104, and FAR 11.105.

Test Your Knowledge

A draft specification sets the sill profile, metal thickness, and finish in generic terms. A different requirement sets a measurable water-entry limit under a stated test and allows compliant assemblies. What methods are the two requirements using?

A

Proprietary for the profile and reference standard for the acceptance limit

B

Descriptive for the profile and performance for the acceptance limit

C

Performance for the profile and descriptive for the acceptance limit

D

Reference standard for the profile and proprietary for the acceptance limit

Test Your Knowledge

A project requires Type V portland cement, but the only draft requirement reads “Portland Cement: ASTM C150/C150M.” What should the specifier correct?

A

Identify Type V and the applicable edition under the project’s reference rules.

B

Remove the citation because published standards cannot be incorporated by reference.

C

Replace the citation with a restriction to a specific manufacturer.

D

Leave the requirement as written because the standard citation specifies Type V automatically.

Test Your Knowledge

A federal agency plans a brand-name-or-equal chiller description under FAR 11.104. What should it include to allow comparable offers while meeting the facility’s needs?

A

A named product and a prohibition on alternatives without restriction justification

B

A list of preferred manufacturers with no criteria for equality

C

The basis-of-design product and salient characteristics such as required capacity, dimensional limits, and controls compatibility

D

Only a safety listing, leaving capacity and service constraints for the selected contractor to decide

Sections you finish are checked off in the contents.