7.9 Verifying Hole and Feature Size
Key Takeaways
Master a comparative bore gage with the approved reference and verify how the instrument reports diameter above or below it.
Sweep for the measuring reversal defined by the gage and sample the specified depths and directions.
A plain GO/NO-GO check uses a released gaging method. It does not deliver a numerical diameter or establish hole position.
7.9 Verifying Hole and Feature Size
Ask what the drawing and plan require
A cylindrical hole, shaft or opposing parallel width can be a regular feature of size. Begin with the limits and geometry on the released drawing, and check what the inspection plan requires at the land, along the length and around the feature. Measured local diameter, form or an envelope decision, and position are separate questions. The diameter of a hole can be within limits while its center has shifted from the specified location. A plain size check does not establish a datum-aligned position result like the one in 7.5. For a narrow slot, a caliper that touches only its chamfers is reading a different width from the one on the drawing.
Choose a variable method when the process decision needs a number, such as watching for diameter drift deeper in a bore. Choose a qualified GO/NO-GO method when the released procedure calls for a limit check. A two-point comparator provides diameter information in the directions and sections sampled. It can reveal changes between those readings, but cannot by itself characterize every possible form error. For an external feature use an outside gage at the locations and orientations specified; keep edges and interrupted surfaces out of the contact unless the procedure includes them.
Master and sweep a bore comparator
- Match the head, anvils and range to the hole and choose the approved reference, usually a calibrated ring of suitable size for this setup.
- Clean the instrument and ring, seat the contact, and rock the head through the reversal using its centering arrangement and procedure. Set the master reading at that reversal.
- Confirm which pointer motion means a larger diameter with a known difference or the documented setup convention. On some gages the pointer direction and bore-size sign use opposite senses.
- Keep the method, temperature conditions and contacts consistent when transferring the setting to the work.
Insert the head without striking the rim, set the indicated depth from the correct end, and rock gently through the same reversal. In a simple cylindrical bore, a tilted two-point measuring line across the bore can span greater than the diameter. The tool's centering and contained rocking method let you find the appropriate turning point; the required high or low pointer reading depends on the indicator sense. Repeat at several depths and permitted angular orientations. Keep records where individual measurements are relevant, since averaging can conceal an oversize or undersize section. Recheck the master after the series, especially if a result is close to a limit.
For a calibrated ring diameter of 0.7501 in, a reading already translated into a bore difference of +0.0004 in gives 0.7505 in. A second reading of −0.0003 in relative to the same ring gives 0.7498 in. That difference is 0.0007 in. Both observations should remain in the record. If drawing limits are 0.7500 to 0.7510 in, the low value lies below the lower limit and needs the disposition specified for the measurement uncertainty and inspection procedure. Adjusting based on an average would miss the low observation.
A telescoping transfer gage captures a distance for reading with an outside micrometer. Use the model procedure to seat and sweep its contacts, retain the setting for removal and transfer it with the proper force at the micrometer. It does not have its own calibrated diameter scale. A suitable small-hole transfer gage uses expandable contacts; select a head and geometry that can reach the measurement region and repeat the transfer. Read a direct inside micrometer using its own range and contact geometry. A deep bore, narrow land or inaccessible bottom may require purpose-specific equipment.
Apply the designated limit gages
For a plain bore the GO plug is ordinarily sized at the minimum limit with the specified gage allowance and the NO-GO plug at the maximum limit with its specified allowance. For example, Vermont Gage describes a common plus tolerance for the GO plug and a minus tolerance for the NO-GO plug in this application. This sign concerns manufacture of the gage. The product tolerance, actual effective gage limits, wear policy, and depth and force rules come from the released plan. Confirm that the gage has the intended marking, measurement region and current status. For a clean, unthreaded through-bore whose plan calls for full-length GO engagement and no NO-GO entry into the size-bearing land, run both checks without forcing. A NO-GO tip entering a countersink alone must be distinguished from entry into the controlled bore. Use the specified procedure for ambiguous conditions.
Mitutoyo bore-gage operation, Starrett telescoping gages, Vermont Gage plug tolerances and ASME Y14.5
A bore comparator is mastered on a certified 1.0002 in ring. In the verified sign convention the part reads −0.0005 in smaller than the ring. What does the instrument estimate?
0.9995 in
0.9997 in
1.0002 in
1.0007 in
A plain, qualified GO/NO-GO plug set confirms a bore under its size inspection plan. Which feature requirement still needs its own inspection if called out?
Whether the plug is identified for that inspection
Whether the part and plugs were clean at the time of the check
The hole’s position relative to the referenced datums
Whether the operator performed both plain plug checks
A deep bore reads 0.6254 in at the opening and 0.6246 in near the bottom. Limits are 0.6250 to 0.6260 in. What is the right response?
Keep both readings and handle the low observation under the inspection procedure
Average the readings to 0.6250 in and accept the bore
Use only the opening reading because the master ring is short
Round both readings to 0.625 in and accept them
A chamfer admits the tip of a NO-GO plug, but the plug stops before the size-bearing land. Which information governs the next decision?
Only the length of the probe handle
The nominal depth of the original drill
The universal rule that any contact at the chamfer means failure
The designated gage, controlled land and permitted entry in the released plan
Sections you finish are checked off in the contents.