3.14 Shop Fire Prevention and Response
Key Takeaways
Know the reporting, evacuation and accountability steps before a fire occurs.
An extinguisher rating relates to the burning material and conditions. A combustible-metal fire requires the agent approved for the specific metal hazard.
Use prevention and housekeeping to control fuels and ignition sources. Follow the assigned response and evacuate when it is unsafe to remain.
3.14 Shop Fire Prevention and Response
Plan the response before smoke appears
The emergency action plan tells employees how to report a fire or other emergency, where to evacuate and how accountability is checked. Where a fire prevention plan is required, it identifies major hazards and controls for fuels and ignition sources. Read the plans applicable to the work area. Know the warning method, exit routes, assembly point and the assigned roles. Keep paths and access clear from the start of the shift, including during delivery, temporary staging and chip removal. A fixture cart that blocks part of an aisle can be a problem even when it is there for only one setup.
A chip stream, a combustible liquid and an energized control cabinet can require distinct handling. Recognize accumulations of combustible debris, inappropriate storage of flammable liquid and ignition-producing work nearby. Apply the fuel segregation and ignition controls directed by the fire-prevention plan. Clean leaks through the approved process and report signs of overheating rather than taking a cover off an energized cabinet. Ensure that chip or dust cleanup uses the method approved for the material. Fines can behave differently from bulk stock.
Read the anticipated fire class in the plan
| Fire condition | Class applied in the named situation |
|---|---|
| Paper or wood burning | A, ordinary combustibles. |
| Flammable liquid burning | B, flammable liquid fuel. |
| Energized electrical equipment involved | C, requiring an agent suitable for energized electrical equipment. |
| Combustible metal such as magnesium chips burning | D, with an agent acceptable for that particular metal hazard. |
A general-purpose ABC extinguisher does not claim a D rating. Verify the actual approved Class D protection for the material and the hazards in the area. If a suspected metal fire starts, don't select an agent based merely on the fact that the cutting machine is electrically powered. The burning material matters. Your role and the conditions can still dictate evacuation. Where OSHA 1910.157 applies to portable extinguishers for employee use, selection considers both the anticipated class and the degree of hazard. Paragraph (d)(6) addresses Class D distribution in the applicable combustible-metal working areas. Designated-use and evacuation-only workplaces must follow the requirements that apply to their arrangements.
Choose the safe next action
If the shop directs immediate evacuation, report the emergency as instructed, leave by the designated safe route and report to the assembly point. Do not stay because a portable extinguisher happens to be mounted nearby. A request to operate an extinguisher requires the assigned role and relevant instruction. OSHA 1910.157(g) distinguishes employee education where extinguishers are provided for use from training for designated equipment users. Review your actual plan before relying on a general extinguisher lesson.
In a workplace that authorizes a trained employee to attempt an incipient-stage response, use the plan. Alert others and report the incident. An incipient-stage decision depends on the fire being small and contained, on an appropriate available extinguisher and on keeping a clear exit route. If flames spread, smoke accumulates or the path becomes uncertain, leave. Use no extinguisher for a fuel outside its approved application. If an attempt under the plan does not promptly control the fire, withdraw. Follow emergency responders' directions and do not re-enter on your own authority.
Apply the plan to two setups
A cart of magnesium turnings is smoking next to a machine. A trainee sees an ABC unit, but the area plan requires evacuation for everyone except trained designated employees. The trainee follows the reporting and evacuation procedures while designated personnel and responders use the plan. The nearby ABC extinguisher does not establish suitable metal-fire protection.
In another area a rag bin near a closed cabinet shows only light smoke, but the assigned evacuation route is partially blocked. Warn and report as required, use a safe alternate route as the plan permits and report to the assembly point. The absence of visible flames is insufficient evidence that the smoke or the space is safe. Correcting storage or housekeeping before the shift can prevent this obstacle.
OSHA exit-route requirements, OSHA emergency action plans, OSHA fire prevention plans, OSHA extinguisher rules and OSHA fire response decision guide
The site plan requires evacuation for your role. A small fire is visible. What should you do?
Use a nearby extinguisher before reporting
Wait beside the machine until the incident has spread
Close off the exit to keep smoke inside
Follow the plan’s reporting and evacuation steps and report to the assembly point
Which class applies to burning magnesium turnings?
Class A
Class D, with an agent approved for the particular metal hazard
Class C because the machine uses electricity
Class B because the material came from a machine
A trained, designated employee sees a fire spreading as the escape route becomes uncertain. What should the employee do?
Approach from deeper inside the area
Finish moving stock through the blocked route
Withdraw and evacuate under the emergency plan
Make the fire an incipient-stage fire by using a smaller extinguisher
A cart routinely blocks access between the workstation and the marked exit. What is the appropriate prevention action?
Remove the obstruction through the site procedure and keep the exit route clear
Keep the cart there until the next fire drill
Mark the cart with an HMIS label and consider the route clear
Assume personnel can always move the cart in an emergency
Sections you finish are checked off in the contents.