6.3 Position, Material Conditions and Virtual Condition

Key Takeaways

  • Position controls the location relationship defined by the basic geometry and feature control frame.

  • Use the applicable envelope size in axis-method bonus arithmetic. When the MMC or LMC surface interpretation conflicts with the axis method, the surface interpretation governs under ASME Y14.5-2018.

  • For common cylindrical position-at-MMC cases, the internal virtual boundary is MMC minus the stated tolerance, and the external virtual boundary is MMC plus the stated tolerance.

  • Rule 1 applies to regular features of size unless a stated exception or override applies. Size limits and the applicable envelope remain separate checks.

Last updated: November 2026

6.3 Position, Material Conditions and Virtual Condition

Read position and modifiers together

Read the frame against the actual feature. For the common case of a diametrical position tolerance on a hole referenced to A, B and C, the basic dimensions and datum references place and orient the nominal position zone. A slot often has a parallel-plane zone referenced to nominal center-plane geometry. Some frames control the relationship between features without locating the group to a separate datum. Use the drawing edition and the actual attachment.

Limit or modifierHolePin
Maximum material condition (MMC)Smallest permitted diameterLargest permitted diameter
Least material condition (LMC)Largest permitted diameterSmallest permitted diameter
No material condition modifier after an applicable position tolerance valueRFS, the stated tolerance is independent of sizeRFS, the stated tolerance is independent of size

Read a material modifier after a datum letter as a datum boundary instruction, such as MMB or LMB when applicable. An unmodified datum reference uses RMB unless otherwise specified. Clearance at a permitted fixed datum boundary can allow relative movement while respecting datum precedence and the specified constraints. This movement differs from extra tolerance on the controlled hole or pin. The amount cannot be inferred from the measured diameter of the controlled feature.

Use the correct size for the position model

In the axis method at MMC, ASME uses the size of the unrelated actual mating envelope (UAME). For a hole it is the largest similar perfect cylinder that fits within the actual surface, free of datum constraints. For a pin it is the smallest similar perfect cylinder containing the actual surface, also free of datum constraints. A local two-point reading can help check size limits. It cannot in general substitute for the mating-envelope size of a tapered, lobed or bent feature.

For a common cylindrical MMC case with no additional cap on the available tolerance:

Axis-method stepHolePin
BonusUAME diameter minus MMCMMC minus UAME diameter
Allowed diametrical positionStated tolerance plus bonusStated tolerance plus bonus
Fixed virtual-condition (VC) boundaryMMC minus stated toleranceMMC plus stated tolerance

The surface interpretation is the controlling method at MMC or LMC if it disagrees with the axis-method result. In the hole example the actual hole surface must clear the fixed theoretical boundary at the basic location. In the pin example the actual surface must fit inside its fixed boundary. The specified size limits apply too. A physical functional gage designed for a particular frame can embody the boundary. Its clearance or rejection does not give a numerical position value, and other requirements may need separate inspection.

LMC can be used when retaining material, such as minimum wall thickness, is the functional concern. The comparable axis-method calculation uses the size of the unrelated actual minimum material envelope and measures departure from LMC toward MMC. For a hole, that envelope is the smallest perfect cylinder containing the opening; for a pin it is the largest perfect cylinder within the material. The controlled material boundary and the size limits still apply.

Work two MMC calculations

Hole. The limits are ⌀0.495–0.505 in and position is ⌀0.010 in at MMC relative to A, B and C. For a straight, round teaching feature with a 0.498 in UAME, the axis-method bonus is 0.003 in and the allowed position diameter is 0.013 in. The fixed boundary is 0.495 − 0.010 = 0.485 in. The 0.485 in number describes the hole’s specified clearance boundary relative to its references. A mating part also has its own size, location and orientation requirements.

Hole UAME (in)Departure from MMC (in)Allowed position diameter in the stated model (in)
0.4950.0000.010
0.4980.0030.013
0.5000.0050.015
0.5050.0100.020

Pin. The limits are ⌀0.746–0.754 in with position ⌀0.004 in at MMC. An unrelated mating cylinder of 0.748 in gives 0.754 − 0.748 = 0.006 in bonus and 0.010 in allowed position in the axis model. The external VC is 0.754 + 0.004 = 0.758 in. Its magnitude is fixed for this callout, even when the part differs from MMC. Comparing a 0.758 in external VC to a 0.485 in internal VC would be meaningless as a fit check for these two independent examples.

Apply the size envelope separately

ASME Y14.5-2018 Rule 1 normally confines the surface of a regular feature of size by a perfect-form envelope at MMC. For example, a shaft with size limits of 0.990–1.000 in can have acceptable local readings around 0.996 in and still fail if the smallest perfect cylinder containing it is 1.002 in. A bow can make the whole-surface envelope fail while local diameters look good. There is no default perfect-form boundary at LMC; the specific requirement governs when a geometric tolerance applies at LMC.

Read the exceptions and overrides. They include qualifying surfaces retained as furnished under an applicable stock standard, tolerances with the free-state modifier, and specified form controls applied to the size feature as described in Sections 5.8 and 8. The independency symbol removes the Rule 1 form control on the size dimension it modifies. An ordinary surface form callout or thin wall alone cannot determine whether an exception applies.

ASME Y14.5-2018, Sections 3, 5.8–5.9, 7.11 and 10, and ASME Y14.43 fixture and gage principles

Loading diagram...
MMC Axis-Method Example and Fixed Hole Boundary
Test Your Knowledge

A drilled hole has diameter limits 0.375 to 0.385 in. What is its MMC size?

A

0.385 in

B

0.380 in

C

0.010 in

D

0.375 in

Test Your Knowledge

A hole has size limits 0.250–0.258 in and position ⌀0.005 at MMC. Its measured local diameter is 0.256 in at the mouth, and its UAME is ⌀0.254 in. What position allowance does the axis method calculate?

A

0.005 in

B

0.004 in

C

0.009 in

D

0.011 in

Test Your Knowledge

With no Rule 1 override, a shaft with a 1.000 in upper limit has local diameters below 1.000 in, but the smallest full-length cylinder that contains it is 1.002 in. Which decision follows?

A

The shaft violates the MMC size envelope

B

The shaft passes because local size alone is decisive

C

The shaft is subject only to an LMC boundary

D

The shaft has a diametrical position error of 0.002 in relative to a datum

Test Your Knowledge

An external pin has size limits 0.990–1.000 in and position ⌀0.002 at MMC. Its unrelated mating envelope is ⌀0.992 in. What are the axis-method bonus and fixed virtual condition?

A

0.002 in bonus and ⌀0.998 in VC

B

0.008 in bonus and ⌀1.002 in VC

C

0.010 in bonus and ⌀1.008 in VC

D

0.012 in bonus and ⌀0.992 in VC

Sections you finish are checked off in the contents.