7.8 Using Dial and Travel Indicators

Key Takeaways

  • Align a plunger with the intended displacement and preload enough for travel in both directions.

  • Read the revolution counter together with the dial graduation, and verify the sign by moving in a known direction.

  • Use the model’s stylus and correction for a lever indicator at an angle. For critical measurements, arrange the setup to minimize that angle.

Last updated: November 2026

7.8 Using Dial and Travel Indicators

Choose the geometry of the setup

A plunger dial indicator senses axial travel along its spindle. A lever test indicator senses movement at the stylus through a pivot. A long-travel plunger indicator can measure fixture or stop movement over several revolutions. A short-travel test indicator can fit where a plunger cannot, such as sweeping a vise jaw or indicating a radial surface inside a bore. Check range, graduation, repeatability and permissible stylus configuration rather than choosing by appearance. A lever swapped for one of a different length can change the indication.

  1. Mount the instrument rigidly with a suitable clamp or stand. Select a contact point that will seat on the surface throughout the move.
  2. Position the plunger spindle along the displacement you need to measure. Use a clean, stable surface and preload to maintain contact in both directions.
  3. Check both ends of the expected travel without reaching a stop. Note whether another pointer revolution occurs before either extreme. If the clamp bends or slips under light contact, correct it before reading. Return to the starting reference after the sweep. A changed baseline calls for checking the mount and contact before interpreting the height difference.

For a drop-indicator comparison, start with a suitable reference artifact on the base and bring the plunger onto the reference face. Set or record the baseline, then substitute the part at the same planned position. Approach in the same direction to make repeatability easier to judge. Check whether a known increase moves the pointer in the expected direction. With a clean 0.5000 in reference, a properly signed +0.0012 in difference gives 0.5012 in if the instrument's resolution and method support that readout. Reinsert the reference after the trial. A shifted reference reading can indicate movement, contamination or a change in the contact arrangement.

Read the dial across full turns

On the Mitutoyo 2416S, one full turn corresponds to 0.100 in and each small division corresponds to 0.001 in. This is one model, with 1 in total travel. In a setup with travel measured from zero in the positive sense, two full turns and 36 divisions indicate 0.236 in. Check the counter and the sweep direction, especially when the pointer passes zero. If a reference is recorded at +0.148 in and a subsequent position is +0.242 in on the same travel scale, the difference is +0.094 in. Subtract in the same reference system instead of subtracting pointer labels that omit an intervening revolution.

When sweeping a fixed part surface, record the high and low positions and their signed readings. A change from −0.0015 in to +0.0005 in on a suitable indicator is a 0.0020 in spread. For a vise use the alignment feature and traverse from the setup plan. For a radial runout check use the fixture or datum axis required by the drawing and keep the spindle stopped and secured against unintended drive during approved manual verification. A high-to-low spread in one trace refers to the feature, location and setup sampled. To compare another radius or station, keep the specified datum and reference. Tramming and runout use similar readings for different objectives.

Control the lever angle

In the Mitutoyo lever geometry shown in its quick guide, the intended surface displacement is normal to the surface. The stylus is set as close as possible to parallel with the surface, with the specified contact point. For a nonzero angle in this setup, the manufacturer multiplies the indication by its compensation factor. Its 30° example uses 0.87; thus an indication of 0.0020 in corresponds to about 0.00174 in. Keep the angle small or reposition the holder for close decisions. Follow the model and setup rather than transferring that correction to a plunger.

For an idealized plunger tilted away from motion normal to a flat surface, the plunger travels farther than the change in normal height by the inverse of the cosine of the tilt. The contact slides on the face as it follows the height. Other contact paths can cause different errors or side loads. The practical remedy is to align the sensing axis with the intended movement. Evaluate the angle effect against the drawing limit and readout uncertainty before treating it as negligible.

Mitutoyo indicator checkpoints, Mitutoyo indicator catalog and Mitutoyo lever cosine guide

Test Your Knowledge

A travel dial moves from zero in the positive direction. The instrument advances 0.100 in per revolution and 0.001 in per division. What does one full revolution and 27 divisions indicate?

A

0.027 in

B

0.127 in

C

0.100 in

D

0.270 in

Test Your Knowledge

For the Mitutoyo lever setup that uses a 0.87 factor at a 30° angle, what displacement corresponds to 0.0040 in indicated?

A

0.00460 in

B

0.00400 in

C

0.00348 in

D

0.00120 in

Test Your Knowledge

A properly aligned dial indicator scans a surface relative to the same reference. The highest value is +0.0020 in and the lowest is −0.0010 in. What is the spread?

A

0.0030 in

B

0.0020 in

C

0.0010 in

D

0.0015 in

Test Your Knowledge

A preloaded plunger loses contact during the negative part of a sweep. What is the correct next step?

A

Subtract a full turn to recover the missing readings

B

Zero only at the extreme and keep the data

C

Increase the sweep speed near that location

D

Reposition the instrument so the setup stays within usable travel, then repeat the sweep

Sections you finish are checked off in the contents.