8.1 Working Near AC Overhead Line Equipment
Key Takeaways
Treat the equipment as live unless the required electrical arrangements establish its status. A switch-off message alone does not permit touching it.
Handbook 16 requires at least 2.75 metres from live OLE, pantographs and associated roof equipment unless all specified precautions for the closer work are in place and carried out.
Carry long items horizontally and get assistance when necessary. Consider the closest approach throughout the whole task.
Keep clear of broken wires and objects on or near OLE. Ensure the ECO is informed and tell the signaller where train operations may be affected.
Identify the electrical hazard
Handbook 16 Issue 7 applies on relevant AC electrified lines. Before going on or near the line in an area with overhead line equipment (OLE), confirm that the Personal Track Safety competence is valid for overhead electrification. Use the Sectional Appendix and notices to identify electrification and any newly energised equipment. If the state of equipment is uncertain, treat it as live. A 25 kV overhead system can injure or kill without someone actually grasping a conductor. Tools, long items, pantographs and associated electrical equipment can bring the hazard to a person who is standing clear of the wire itself.
| Feature | Why identify it in the briefing? |
|---|---|
| Contact wire, catenary and droppers | The contact wire is where the pantograph collects power. Other wires above it are part of the overhead system and may also present a hazard. |
| Pantograph and roof-mounted electrical equipment | The danger can also be above a vehicle, including where a person or an object could approach from a platform, bridge or raised work area. |
| Return conductors, feeders and structures | Different equipment can be present on the same structure. Use the electrical arrangements and instructions to identify what is safe and what remains live. |
| Nearest structure identification plate | It gives the ECO a precise reference when you report damaged equipment. Obtain the reference without approaching the hazard. |
Control the closest approach during the work
Under Handbook 16 section 4.1, keep yourself and anything you are holding at least 2.75 metres in any direction from live OLE, pantographs and associated roof-mounted equipment. Closer work requires an applicable method statement or company instruction, all specified precautions in place and the worker carrying them out. Network Rail’s applicable SAI25 documents include lists for approved work categories. A worker cannot use the existence of a listed category to approve a different task. For work requiring isolation and an overhead line permit, use the applicable electrical arrangements and understand the confirmed limits before starting.
Under section 4.3, carry long items horizontally, use help when necessary, and follow the task precautions, including the correct selection and use of insulated ladders. Consider changes in height and the path of an entire object as it is lifted, moved or turned. A planned distance to the worker’s feet is an inadequate check for the tip of a tool. Do not assume a replacement tool or a possession removes the electrical hazard.
Worked clearance check
A survey needs a measuring staff near live OLE. The closest planned distance from its tip would be 2.4 metres while moving it into position. Since 2.4 < 2.75, that movement does not satisfy the ordinary clearance rule. The COSS keeps the group clear while the person in charge checks the appropriate electrical arrangements. A revised method might avoid the close approach by changing how or where the measurement is made. If the work still requires closer access, use only the applicable electrical control with the specified precautions in place. Recheck the group’s protection from trains separately.
Broken wires, defects and switch-off
Treat broken or displaced wires and objects attached to or near OLE as live and dangerous. Keep the group clear. Do not approach or attempt to move the object. Under section 3.3, make sure the electrical control operator (ECO) is informed immediately. Tell the signaller if the defect can affect train operations or if you do not normally speak directly to the ECO. Identify the affected line and nearest OLE structure from safety and describe the hazard.
When the circumstances require, or are likely to require, emergency switch-off, use section 6 and contact the ECO immediately or arrange for that contact. Open an emergency call with “This is an emergency call”. Give your identity, the line and precise location, contact number, why switch-off is needed, whether anyone is in danger from the OLE and whether emergency services are waiting to help. Stay in contact until told that the OLE is safe to approach without touching, or until another arrangement is made. An emergency switch-off does not establish an isolation, a permit or a stoppage of trains. Section 7 governs any attempted rescue near OLE. Follow the applicable emergency arrangements and keep the group clear of both electrical and movement hazards.
Under Handbook 16, what distance applies to the worker and anything they hold near live OLE when no approved closer-working precautions are in place?
1.25 metres
2.75 metres
4 metres
5 metres
A broken overhead wire is lying across the ballast. What should the COSS have the group do?
Move it with a non-metallic tool
Approach the wire to look for sparks before reporting it
Keep clear, treat it as live and report the defect through the applicable ECO and signaller routes
Use a completed blockage record as proof the electrical equipment is safe
Which role issues an overhead line permit under Handbook 16?
Nominated person (NP)
Engineering supervisor (ES)
Site lookout
Person in charge of the possession (PICOP)
Sections you finish are checked off in the contents.