7.6 Part 9 Application, Sloped Roofs and Industrial Suites
Key Takeaways
Confirm the Part 9 height, building area and major occupancy requirements in Division A. Check the retirement-home exclusion and existing-building rule.
Section 9.1.1. includes cross-references to specific provisions elsewhere in Division B and separate radon, flood-plain and factory-construction rules.
For Section 9.10, treat a roof as a wall when it slopes at least 60° to the horizontal and is adjacent to a room or space intended for occupancy.
Article 9.10.9.14. generally limits residential suites in a Group F, Division 2 building to one. Check whether the industrial major occupancy is directly related to live/work units.
Check whether Part 9 applies
Division B 9.1.1.1. directs the reader to Division A Subsection 1.3.3. Under 1.3.3.3., subject to the existing-building rule in 1.3.3.3B., check that building height is three storeys or less and building area is 600 m² or less. The allowed major occupancies are Group C residential other than retirement homes, Group D business and personal services, Group E mercantile, and Group F Divisions 2 and 3 medium- and low-hazard industrial. Use the Code’s building-area and building-height definitions. A Group C apartment over a Group E shop can satisfy the scope conditions on the stated dimensions. A retirement home of the same size does not satisfy the Group C condition.
Route the special items in Section 9.1
| Subject | Provision to check |
|---|---|
| Signs and self-service storage buildings | 9.1.1.2. refers signs to Section 3.15. and 9.1.1.3. refers self-service storage to Section 3.10. |
| Tents and air-supported structures | 9.1.1.4. refers tents to 3.14.1. and air-supported structures to 3.14.2. |
| Proximity to existing overhead conductors and food premises | 9.1.1.5. refers close proximity to 3.1.20. and 9.1.1.6. applies 3.7.6. to all food premises. |
| Radon and flood plains | 9.1.1.7. applies both annual-average limits in the named areas. Article 9.1.1.8. requires consideration of both hydrostatic pressure directions and floodproofing that preserves exits and means of egress. |
| Factory-built buildings | Under 9.1.1.9., subject to Sentence (2) and 12.2.1.2.(2), the stated paths are compliance with CSA Z240.2.1 for sections no wider than 4.88 m, or CSA A277. Components designed and constructed outside the place of manufacture and the site installation remain subject to the Code. |
| Public pools, public spas, and shelf and rack storage | 9.1.1.10. refers to Sections 3.11. and 3.12. for pools and spas respectively. Article 9.1.1.11. refers shelf and rack storage systems to Section 3.16. |
For example, a small shop can meet the height, area and occupancy limits while still using the specified Part 3 provisions for a sign or food premises. This does not turn the whole project into a Part 3 building.
Treat the qualifying sloped surface as a wall for fire protection
Under 9.10.1.1., the roof must meet both conditions: a slope of 60° or more to the horizontal and adjacency to a room or space intended for occupancy. When both apply, treat that portion as a wall for Section 9.10, Fire Protection. A 60° mansard surface adjacent to a bedroom meets both conditions. A 59° surface does not meet the angle condition, and a 65° roof adjacent only to a space stipulated to be outside the occupancy condition does not meet both. Apply this classification to the relevant requirements of Section 9.10.
Assess the actual industrial and residential uses
Under 9.10.9.14., a building classified as Group F, Division 2 is generally limited to one suite of residential occupancy. The stated qualification concerns a Group F, Division 2 major occupancy directly related to live/work units. Two conventional residential suites over a continuing, unrelated industrial occupancy fall under the general limit. Calling the units lofts does not prove the required relationship. A genuine live/work proposal must also be checked against the rest of the applicable Code, including the provisions governing the proposed occupancies and their fire separations.
A two-suite conversion question can involve several decisions. Identify whether the industrial occupancy will continue, test the live/work facts if raised, and check the applicable permit for the work or use change. The suite-limit article answers the suite question when the stated industrial occupancy remains. It does not by itself set a universal required fire-resistance rating or decide whether a use change requires a permit under Act s. 10.
Consider a step-by-step review of a 600 m², three-storey building with a continuing Group F, Division 2 occupancy. The stipulated dimensions and classification permit beginning with Part 9. The number of residential suites still needs its own review under 9.10.9.14. If an allowed suite includes a bedroom next to a mansard at exactly 60° to horizontal, the roof provision applies independently. Check Section 9.10 requirements for the resulting wall classification and the separation provisions for the actual occupancies. Changing the shape of the roof does not change the industrial and residential classifications.
Primary references
2024 Compendium, Division B Part 9 · 2024 Compendium, Division A · Building Code Act, 1992
Which new building satisfies the stated Part 9 size and occupancy thresholds under Division A 1.3.3.3.? Treat the areas as building area and the storeys as storeys in building height.
Two storeys and 400 m², with Group C accommodation in a retirement home.
Four storeys and 420 m², with Group D offices and no residential accommodation.
Three storeys and 600 m², with Group E retail and ordinary Group C apartments.
One storey and 650 m², with Group F, Division 3 industrial occupancy.
Which roof meets both conditions in Division B 9.10.1.1. to be considered a wall for Section 9.10?
A 60° roof to the horizontal adjacent to a bedroom.
A 59° roof to the horizontal adjacent to a bedroom.
A 65° roof to the horizontal adjacent only to space stipulated to be outside the occupancy condition.
A 55° roof to the horizontal adjacent to a family room.
An ordinary Group F, Division 2 building will retain its industrial use. Two conventional residential suites are proposed and the industrial major occupancy is unrelated to any live/work units. What follows under 9.10.9.14.?
Any number is permitted if the area is under 600 m².
The normal limit is one residential suite.
The second suite is permitted because it is on another storey.
The article permits two suites because Group F, Division 2 falls within Part 9.
A shop within Part 9 proposes work involving an applicable Code-regulated sign. Which provision does Article 9.1.1.2. direct the reviewer to use for signs?
Division B Section 2.1.
Division B Section 3.10.
Division C Section 1.4.
Division B Section 3.15.