7.4 Environmental Separation and Fenestration Standards
Key Takeaways
Under 5.9.1.1., check whether the material or component is in an environmental separator or an assembly exposed to the exterior and installed to fulfill Part 5.
Apply the flame-spread requirements contained in thermal insulation standards only as Part 3 requires.
Article 5.9.2.2. uses both the Harmonized Standard and Canadian Supplement. Select an appropriate performance grade using the Supplement and verify it by testing under the Harmonized Standard.
Check the wired-glass exception, coverage of the named standards and the separate treatment of other fenestration assemblies before applying the standards.
Check the installation and the table
Division B Part 5 addresses environmental separation. Use the Division A application rules and the project’s applicable Code provisions to determine when Part 5 governs. Under 5.9.1.1.(1), materials and components and their installation must conform to applicable standards in Table 5.9.1.1. when they are part of an environmental separator or assembly exposed to the exterior and are installed to fulfill Part 5. Read the exceptions in the article and elsewhere in Part 5. The table connects material and component categories with standards. Division A 1.5.1.3. and Division B 1.3.1. identify how to confirm the edition.
A product may appear in more than one application. For example, find out whether an insulation product is used in an environmental separator to fulfill Part 5. Then check the relevant table row and any separate performance requirements. Sentence 5.9.1.1.(2) directs that flame-spread-rating requirements contained in thermal insulation standards apply only as required in Part 3. Read the Part 3 requirement that applies to the proposed use before treating the standard’s rating as a requirement for that installation. The sentence does not remove the other applicable provisions in the table.
Identify the assembly before assigning its standard
Subsection 5.9.2. applies to windows, doors and skylights and their components separating the interior from the exterior or separating environmentally dissimilar interior spaces. Its skylight term covers unit skylights, roof windows and tubular daylighting devices. Article 5.9.2.1.(3) allows a wired glass assembly installed in a required fire separation to be exempt from that subsection. Establish both facts. The presence of wired glass by itself does not determine which provisions apply.
| Assembly or situation | Review route |
|---|---|
| Window, door or skylight in the subsection’s scope and covered by the named standards | Apply 5.9.2.2. and confirm the suitable performance grade. |
| Window, door, skylight or component in the subsection whose product is outside the scope of the named standards | Article 5.9.2.3. directs design and construction to 5.1.4.1., 5.4. and 5.6. for that case. |
| Curtain wall, window wall, storefront or glazed architectural structure | Check the separate provisions for other fenestration assemblies in 5.9.3. |
| Wired glass assembly installed in a required fire separation | Apply the exception in 5.9.2.1.(3) and check the remaining applicable Code requirements. |
An unsupported report from a supplier and an assembly outside a standard’s scope are different facts. If a window is within the scope, the provisions apply even if the supplier has not supplied documentation. For an assembly outside the scope, check the prescribed design route. For a proposed alternative solution, review its documentation under Division C 2.1 and the required performance under Division A 1.2.1.1.
Select and verify the performance grade
Under 5.9.2.2.(1), the named documents are AAMA/WDMA/CSA 101/I.S.2/A440 and the CSA A440S1 Canadian Supplement. The editions table designates A440-17 and A440S1:19 for this reference. Sentence (2) uses the Canadian Supplement to select the performance grade appropriate to the conditions and geographic location of installation. Sentence (3) requires the product to meet the selected grade when tested under the Harmonized Standard.
For example, a proposed exterior window has test evidence under the Harmonized Standard. First establish the required grade for the actual installation using the Canadian Supplement. Then verify whether the submitted test covers the proposed product and demonstrates that grade. The same model may be proposed for two sites with different conditions. A grade demonstrated for the first project does not establish the required grade on the second project. Where the drawing shows a curtain wall instead of a window covered by the standard, start with the applicable 5.9.3. rules before deciding what evidence to require. Use Division A 1.5.1.2. if an applicable provision of a referenced standard conflicts with the Ontario Code.
Consider a project with exterior windows, a glazed storefront, and a wet-room door separating environmentally dissimilar spaces. The product name on the schedule is the starting point. Identify which doors and windows are within 5.9.2., whether the named standards cover each product, and whether the storefront fits 5.9.3. Check the selected window performance grade against the installation conditions and the corresponding test. If the schedule changes, match the submitted test to the replacement model and verify the effect on the applicable performance. A grade for one product is evidence for that product under its test conditions.
Primary references
2024 Compendium, Division B Part 5 · 2024 Compendium, Division B standards table · 2024 Compendium, Division A · 2024 Compendium, Division C Part 2
A referenced thermal insulation standard has a flame-spread rating requirement. When does 5.9.1.1.(2) apply that requirement?
Whenever the insulation data sheet lists it.
Only as required by Part 3.
Only when the product was imported.
Only when the assembly is subject to a local zoning by-law.
What is the sequence for a covered exterior window under 5.9.2.2.(2) and (3)?
Select the grade solely using the manufacturer’s brochure and accept the brochure as a test.
Choose a grade based on local zoning and verify it with any testing procedure.
Use the Canadian Supplement only after the product has been installed.
Select a grade appropriate to the site using the Canadian Supplement and verify the grade by testing under the Harmonized Standard.
Which assembly has the specific exception from Subsection 5.9.2. in Article 5.9.2.1.(3)?
A wired glass assembly installed in a required fire separation.
Any window containing wired glass anywhere in a building.
Every glazed exterior door in a Part 3 building.
Every skylight on a steep roof.
The drawing specifies a curtain wall. Which Part 5 subsection expressly addresses curtain walls as other fenestration assemblies?
5.9.1.
5.9.2.
5.9.3.
5.9.4.