7.2 Farm Building Scope and Agricultural Occupancies

Key Takeaways

  • Test actual agricultural use and the occupant load of the agricultural floor area before applying Group G. Exactly one person per 40 m² qualifies for the density side of the Group G test.

  • Group G separates high hazard, other agriculture, greenhouses and agricultural occupancies with no human occupants.

  • Apply the size and height limits and the applicable occupancy division before using the small-farm-building rule. SB-11 is a structural deemed-compliance provision for qualifying low-human-occupancy farm buildings.

  • The exemption for demolition of a farm building on a farm is a distinct permit rule. Check new construction and change of use under their own provisions.

Last updated: November 2026

Start with what each part of the building is used for

Under Division A 1.4.1.2., a farm building is a building or part containing an agricultural occupancy. Agricultural occupancy uses land devoted to farming for functions such as producing crops, raising animals, or preparing, marketing, storing or processing agricultural products. A house on a farm does not acquire an agricultural occupancy because of its address. Division A 1.3.3.1A. directs farm buildings to Division B Part 2. Article 2.1.1.1. describes its scope, including fire, structural, heating, ventilation and air-conditioning performance and operations that create specified life-safety hazards.

Under 2.1.2.2., calculate the occupant load using the floor area, or part of the floor area, that contains the agricultural occupancy. An agricultural occupancy with no more than one person per 40 m² is classified in Group G, in the applicable division. Above that density, classify the occupancy using one of the groups and divisions in Division B Table 3.1.2.1. Classify each major occupancy in a mixed-use building. Do not average a public sales area with a sparsely occupied storage area to produce a single low-occupancy label.

For example, in an agricultural floor area of 480 m², an occupant load of 12 is exactly one person per 40 m². A load of 13 exceeds the limit because 13 people would require at least 520 m² at that density. Classify the occupancy at its actual load. For a separate public sales or catering area, assess its actual use, load, and occupancy classification separately. Under 2.2.1.1.(2), non-Group G portions of a farm building are classified under Table 3.1.2.1. and must conform to Part 3. Check applicable limits on occupancy combinations as well.

Select the Group G division and the requirements

Division under Table 2.1.4.1.Classification
G1High-hazard agricultural occupancies. Check the special-fire-hazard definition and the materials actually present.
G2Agricultural occupancies not elsewhere classified in Group G.
G3Greenhouse agricultural occupancies.
G4Agricultural occupancies with no human occupants under normal use.

Under 2.1.2.1.(1), the larger-building rule applies to described Group G farm buildings when the building area is more than 600 m² or building height is more than three storeys. Sentence (2) specifically excludes Subsections 2.2.6. and 2.2.7. for Group G4. Sentence (3) sends farm buildings not described in Sentence (1) to 2.1.2.3. Apply that article’s sentences to the building’s classification rather than treating all Group G divisions as interchangeable.

Under 2.1.2.3.(1), a G1, G2 or G3 farm building at 600 m² or less and three storeys or less generally follows the National Farm Building Code of Canada identified as NRCC 38732, subject to the Ontario conditions in Sentences (2)–(6). Those conditions disapply certain provisions, redirect specified references to the earlier Ontario Code as stated, and require the SB-1 climatic values. Sentence (5) deems the structural requirements satisfied for a qualifying low-human-occupancy farm building of those dimensions if design and construction conform to SB-11. Other applicable requirements still need to be checked. Sentence (6) sends hazardous cannabis extraction areas to the specified provision. A small building with hazardous operations still needs its actual classification and rules.

Mixed uses can also affect whether occupancies may share a building. Under 2.2.1.2., a G1 or G4 building cannot contain a Group A, B or C occupancy. For G2 or G3, the stated restrictions cover Group A Divisions 1 and 3 and Group B. For example, consider a function room inside a greenhouse building. Establish the room’s actual classification and check the combination rules before using the small-farm-building route. The dimensions of the greenhouse alone cannot answer the function-room question.

Check the permit separately

Under Act s. 8(1), constructing a new building requires a permit unless a specific exemption applies. Under Division C 1.3.1.1.(1)(a), demolition of a farm building located on a farm is exempt from the s. 8 permit requirement. A plan to replace a barn can therefore need a construction permit while the demolition of the existing qualifying barn is exempt. At permit review check applicable law and other requirements separately. If an existing agricultural building will be reused, check both whether construction triggers s. 8 and whether the proposed use triggers s. 10 and Division C 1.3.1.4. A change in occupancy description is a fact to assess under those provisions.

Primary references

Building Code Act, 1992 · 2024 Building Code Compendium, Division A Part 1 · 2024 Building Code Compendium, Division B Part 2 · 2024 Building Code Compendium, Division C Part 1 · NRC National Farm Building Code of Canada 1995

Test Your Knowledge

An agricultural floor area is 480 m² and has an occupant load of 12. How does that load compare with the Group G density threshold in Division B 2.1.2.2.?

A

It exceeds the threshold by one person.

B

It falls on the threshold of one person per 40 m².

C

It qualifies only if the building is no more than one storey.

D

The threshold must be calculated from building area even if some of it is non-agricultural.

Test Your Knowledge

A Group G2 farm building of low human occupancy is three storeys and exactly 600 m² in building area. What can conformity with SB-11 establish under Division B 2.1.2.3.(5)?

A

An exemption from all Code requirements.

B

The owner’s planning permission for the farm use.

C

Compliance with permit requirements for all future alterations.

D

Deemed compliance with the specified structural requirements.

Test Your Knowledge

A building is a Group G4 occupancy described by 2.1.2.2.(1) and exceeds 600 m² of building area. What exclusion does Division B 2.1.2.1.(2) specify?

A

No additional exclusions because the building is larger than 600 m².

B

It excludes all of Part 2.

C

Subsections 2.2.6. and 2.2.7. do not apply to the Group G4 occupancy.

D

The occupancy must be reclassified as Group F1.

Test Your Knowledge

A farmer removes an existing farm building located on a farm and proposes a new 1,400 m² agricultural building for which no specific construction exemption applies. Which Act s. 8 permit statement fits?

A

The new building needs a construction permit, and demolition of the qualifying existing farm building is exempt.

B

The new building is exempt, and the existing farm building always needs a demolition permit.

C

Both must be treated as demolition and neither needs a construction permit.

D

Both are exempt because the land is used for farming.

Sections you finish are checked off in the contents.