4.3 Plug, Slot, Spot, Seam, Stud & Surfacing Weld Symbols
Key Takeaways
Plug and slot weld symbols both resemble rectangles in AWS A2.4:2020. A diameter sign identifies the plug hole size.
Slot width appears on the left. Slot length and straight-row pitch appear to the right. The drawing locates and orients the slots.
Omission of the depth inside the plug or slot rectangle specifies complete filling. Read any contour requirement separately.
Spot diameter and seam width appear to the left. AWS A2.4:2020 specifies strength in the tail.
Study where the arrow points for stud and surfacing symbols. Both appear below the reference line.
Plug, Slot, Spot, Seam, Stud & Surfacing Weld Symbols
Use AWS A2.4:2020 clauses 9–15 to read these callouts. Overlapping doubling plates, shear-stud decks, sheet-metal enclosures, and hardfaced crusher liners all rely on specialized weld symbols to specify the joint or surface, along with the size and layout.
Plug and Slot Weld Symbols
Both plug welds and slot welds join two overlapping members by depositing weld metal through an opening cut in the outer (accessible) member onto the underlying member. Remarkably, both use the exact same basic weld symbol: an open rectangle placed below the reference line (hole/slot in the arrow-side plate) or above the reference line (hole/slot in the other-side plate).
How do you tell a plug weld from a slot weld, and what does each position around the rectangle mean?
| Feature | Plug Weld (Circular Hole) | Slot Weld (Elongated Slot) |
|---|---|---|
| Basic symbol | Open rectangle (arrow side or other side) | Open rectangle (arrow side or other side) |
| Left of symbol | Diameter symbol Ø + hole diameter (e.g., Ø20) | Width of the slot (no Ø symbol, e.g., 16) |
| Inside the rectangle | Depth of filling (if less than full plate thickness); omitted = fill 100% full | Depth of filling (if less than full plate thickness); omitted = fill 100% full |
| Above/below symbol | Included countersink angle of the hole (e.g., 45° or 60°) | Included countersink angle of the slot sides |
| Right of symbol | Pitch (center-to-center spacing, e.g., 150) | Length and, after a hyphen, pitch in a straight row. Find slot orientation on the drawing. |
| Quantity | Number of plug welds in parentheses, e.g., (6), placed above/below symbol | Number of slot welds in parentheses, e.g., (4), plus detail reference in tail if complex |
Critical Inspection Checks for Plug and Slot Welds
- Full vs. partial fill trap: If no number appears inside the rectangle, the welder must fill the entire hole or slot completely to the top surface of the perforated plate (and flush if a contour symbol is added). A partially filled plug weld when no partial depth is specified is nonconforming.
- Perimeter-only fillet trap: A plug or slot weld requires solid fusion across the entire bottom faying surface and full fill to the specified depth. Simply running a fillet weld around the inside rim of a hole or slot is NOT a plug or slot weld—that is a fillet weld inside a hole, which must be symbolized with a fillet triangle, never a plug/slot rectangle!
- Procedure and code: Verify the hole preparation and any required inspection at the interface between members. Measure plug diameter and slot length and width at that interface, called the faying surface.
Spot and Seam Weld Symbols
Spot and seam welds can join overlapping sheet at discrete points (spot) or along a line (seam) using either resistance processes (RSW, RSEW) or arc processes (Arc Spot with GMAW/FCAW/GTAW, or Arc Seam).
1. Spot Weld Symbol (Plain Circle)
- Shape: A plain open circle.
- Side significance:
- Centered on the reference line: Used when side is immaterial, as with some resistance spot welding (
RSW) where two opposing copper electrodes clamp both outer sheets and side direction has no significance. - Placed below (arrow side) or above (other side): Used when side is significant, as for arc spot welding (where the torch burns through the top sheet into the bottom sheet from one accessible side) or when the specification identifies a particular member.
- Centered on the reference line: Used when side is immaterial, as with some resistance spot welding (
- Dimensions:
- Left of circle: Weld diameter if specified by size. If strength is specified, AWS A2.4:2020 puts it in a note in the tail.
- Right of circle: Pitch (center-to-center spacing, e.g.,
50). - Above/below circle: Number of spot welds in parentheses, e.g.,
(10). - Tail: Process designation (
RSW,GMAW-S,GTAW) to distinguish resistance from arc spot welding.
2. Seam Weld Symbol (Circle Crossed by Two Horizontal Lines)
- Shape: A circle intersected by two parallel horizontal lines (tangent/crossing near the top and bottom of the circle, like a wheel on tracks).
- Side significance: Centred when no side significance applies. For side-specific seams, place the symbol below for arrow side and above for other side.
- Dimensions:
- Left of symbol: Weld width if specified by size. If strength is specified, it appears in a note in the tail.
- Right of symbol: Length of continuous seam, or
length-pitch(75-150) for intermittent seam welds.
Stud Weld Symbol
Shear connectors on composite steel-concrete bridges, refractory anchors, and threaded mounting pins are fastened end-on to base metal via Arc Stud Welding (SW).
- Symbol shape: A circle containing an
Xplaced below the reference line (arrow side, pointing directly to the surface where the stud base fuses). Because a stud attaches to one surface only, the stud symbol is not used centered straddling the line. - Dimensions:
- Left of symbol: Specified stud size (e.g.,
19for a 19 mm headed shear stud). - Right of symbol: Pitch (center-to-center spacing along a row, e.g.,
300), or spacing note. - Below the symbol (in parentheses): Number of studs required in that row or pattern, e.g.,
(12).
- Left of symbol: Specified stud size (e.g.,
- Inspector verification: Confirm the stud type, size and surface and any test requirement from the governing project documents. In a straight row of eight studs at 300 mm pitch, seven intervals give a 2,100 mm centre-to-centre span. Verify the drawing's first and last positions rather than inferring edge clearances from pitch.
Surfacing Weld Symbol
A surfacing weld deposits metal on a surface. Examples include restoring dimensions, adding a wear-resistant layer, or depositing corrosion-resistant cladding.
- Symbol shape (AWS A2.4): Two side-by-side semicircular loops/arches (resembling twin side-by-side crescents or a shallow double-hump wave) sitting exclusively below the reference line.
- Strict arrow-side rule: In AWS A2.4, surfacing symbols are always placed on the arrow side (below the reference line) because the arrow points directly to the surface receiving weld buildup—never above the line and never centered.
- Critical Distinction — Surfacing Loops vs. Open Rectangle: Do not confuse the AWS A2.4 twin-arch surfacing symbol with an open rectangle! In AWS A2.4, an open rectangle on the reference line represents a plug or slot weld (or backing when placed on the opposite side of a groove weld, or a spacer when shown within the groove symbol). Always read the twin-loop shape as surfacing.
- Dimensions & notes:
- Left of symbol: Required thickness of the surfacing deposit (e.g.,
5for a specified 5 mm hardfacing pad). - Partial coverage: The drawing shows the extent, location and orientation when only part of a surface is to be welded. A direction note can appear in the tail or on the drawing.
- Left of symbol: Required thickness of the surfacing deposit (e.g.,
Quick Comparison Reference
| Weld Type | AWS A2.4 Symbol | Default Side Placement | Left Dimension | Right Dimension |
|---|---|---|---|---|
| Plug | Open rectangle | Arrow or other side | Ø + hole diameter | Centre-to-centre pitch |
| Slot | Open rectangle | Arrow or other side | Slot width (no Ø) | Length / pitch + detail ref |
| Spot | Plain circle | Centred if no side significance, otherwise arrow or other side | Diameter if specified by size | Centre-to-centre pitch |
| Seam | Circle with 2 horizontal lines | Centred if no side significance, otherwise arrow or other side | Width if specified by size | Length or length-pitch |
| Stud | Circle with X inside | Arrow side (below line) | Stud size | Centre-to-centre pitch |
| Surfacing | Twin side-by-side arches/loops | Arrow side only (below line) | Required deposit thickness | Extent and orientation in the drawing |
A projection weld uses local contact at a formed projection. It can share the spot or projection elementary shape in the AWS basic weld symbols table. Check the process reference and side instruction to tell which application the drawing requires.
On an AWS A2.4:2020 metric drawing, a rectangle below the line shows Ø22 at left, a 45° included countersink angle, 150 at right and no entry inside. What does it specify for the straight row?
Elongated slots 22 mm wide at 45 mm pitch.
A fillet weld around the perimeter of each round hole.
Round holes 22 mm at the faying surface, 45° countersinks, 150 mm centre-to-centre pitch and complete fill.
An other-side backing bar 22 mm wide.
Which AWS symbols represent a resistance spot weld with no side significance and a stud weld on a specified flange surface?
Resistance spot: plain circle centered straddling the reference line; Stud weld: circle with an X placed below the reference line on the arrow side
Resistance spot: plain circle placed strictly below the reference line; Stud weld: circle with two horizontal lines centered across the reference line
Resistance spot: circle with an X centered on the reference line; Stud weld: open rectangle with R inside placed above the reference line
Resistance spot: twin arches placed below the reference line; Stud weld: plain circle with Ø to the left
Select ALL accurate statements regarding AWS A2.4 surfacing weld symbols and their inspection.
Select all that apply
The surfacing symbol consists of twin side-by-side arches/loops placed strictly on the arrow side (below the reference line)
A surfacing weld symbol must be centered straddling the reference line because buildup has no side significance
An open rectangle on the opposite side of a groove weld designates a surfacing buildup layer
A dimension to the left of the surfacing symbol specifies the required deposit thickness.
Sections you finish are checked off in the contents.