10.3 Wire Feeders, Contact-Tip-to-Work Distance (CTWD) & Gas Flowmeters
Key Takeaways
Match drive rolls, liner and contact tip to the wire and feed system.
The contact tip carries current to the moving wire. The nozzle directs shielding gas.
Electrode extension and contact-tip-to-work distance describe different dimensions.
Use the correct gas scale and unit and verify gas delivery at the specified point.
Follow the electrode from spool to arc
A wire feeder moves the electrode through drive rolls, guide and liner to the contact tip. The contact tip transfers welding current to the moving wire. It must be suitable for the wire and process. A tip or liner that binds can interrupt feed. Burnback can fuse wire to the tip when feeding stops while the arc remains. A loose, worn or mismatched tip can affect electrical contact. A congested nozzle or diffuser can alter gas distribution. Check actual parts before attributing an irregular arc to the power source.
| Feed item | Evidence to compare with the equipment instructions |
|---|---|
| Rolls | Correct groove for the electrode type and size. Smooth V-grooves are used for many solid steels, knurled V-grooves for some tubular wires and polished U-grooves for many soft aluminum wires |
| Guides and liner | Correct diameter, material, condition and proper installation. Some aluminum systems use low-friction polymer liners and a spool gun or push–pull arrangement |
| Contact tip and nozzle | Correct wire size and tip position. Look for worn tips, spatter blocking the gas path and an obstruction that prevents consistent feed |
Check roll alignment and the prescribed tension. Too much pressure can deform soft or tubular wire. Birdnesting is wire bunching at the feeder. It can signal blocked or unstable feeding. For example, if the operator changes to aluminum wire and you see shavings at the inlet, record the observation and compare the roll size, groove, guide and liner with the gun and feeder instructions before accepting the setup. Miller feeder roll and guide examples and Lincoln Electric on aluminum GMAW.
Distinguish three distances
Electrode extension runs from the contact tip to the melting end of the wire. Along the wire axis, contact-tip-to-work distance (CTWD) includes the extension and the arc length. The nozzle-to-work distance depends also on where the contact tip sits relative to the nozzle. Changing tip recess can change shielding conditions without the same change in electrode extension.
With a comparable arc, adding electrode extension increases the resistive portion of the wire circuit. In conventional constant-voltage welding with fixed feed and other comparable conditions, a longer extension generally reduces current as the wire is resistively heated before it melts. The complete effects on penetration and shielding depend on the process, setup and settings. Compare actual measurements with the range in the welding procedure data sheet (WPDS) and record departures. TWI on electrode extension and current.
Follow shielding gas to the nozzle
The regulator controls delivery pressure. A flowmeter measures flow under its rated conditions. In a typical vertical variable-area meter, gas lifts a float in a tapered tube. Use the orientation, reference point on the float, gas scale and any corrections specified by its maker. A multi-gas meter can have separate argon, helium and mix scales. Do not apply one scale across gases without an applicable method. Harris flowmeter instructions and Victor flowmeter gas service.
Compare the cylinder or manifold label with the procedure and verify hose, fittings, solenoid, regulator and nozzle using the authorized methods. A suitable nozzle flow gauge can check delivered flow at the gun. Leaks, drafts and inadequate or excessive flow can impair shielding; use the specified range and investigate with the required procedure. Some regulator designs have different ratings for carbon dioxide. Follow the gas equipment instructions for selection and service. TWI on causes of weld porosity and Victor regulator example.
Worked conversion. Convert only at comparable reference conditions. One cubic foot is 28.3168 L and an hour has 60 minutes, so 1 ft³/h is about 0.472 L/min. A procedure requires 16–18 L/min. A reading of 35 ft³/h on the correct gas scale is about 16.5 L/min at comparable reference conditions. It lies in range. An upstream reading cannot by itself establish that the same flow reaches the nozzle. NIST conversion factors for pressure and gas flow.
When a delivery check differs from the upstream setting, note which gauge and scale were used, then have the setup checked before changing the regulated flow. For example, if an approved nozzle gauge shows the required flow but shielding remains poor, check for a draft or an obstructed diffuser. A flow reading alone does not establish effective coverage of the pool.
The feeder manual for this aluminum wire specifies polished U-groove rolls and a low-friction polymer liner. Which setup meets the instructions?
Knurled V-groove rolls with a steel liner.
An unspecified roll matched only to the spool weight.
A narrow roll groove used for a different diameter.
Polished U-groove rolls and the specified low-friction liner.
A procedure specifies 16–18 L/min. A calibrated meter on the correct gas scale reads 35 ft³/h at comparable reference conditions. What is the equivalent reading?
About 16.5 L/min, within the stated range.
About 35 L/min, above the stated range.
About 74 L/min, above the stated range.
About 0.47 L/min, below the stated range.
Order these example gas delivery checks from supply to the point of use.
Arrange the items in the correct order
Check the gas label against the procedure.
Check the meter configuration and correct gas scale.
Verify delivered flow at the gun with the specified method.
Check downstream hoses and connections by the approved method.
Sections you finish are checked off in the contents.