6.1 Shielded Metal Arc Welding (SMAW) & Polarity Characteristics

Key Takeaways

  • Shielded metal arc welding uses a consumable covered electrode. Its covering supplies shielding, slag and other functions depending on the formulation.

  • Compare the electrode and its polarity with the specified procedure and manufacturer information.

  • In vertical welding, verify the specified progression as well as the position.

  • Magnetic arc blow can deflect a DC arc. Record observations and have proposed changes checked against the procedure.

Last updated: November 2026

Recognize the stick welding circuit

Shielded metal arc welding (SMAW) uses a consumable stick electrode with a metallic core and a covering. The arc between the electrode and workpiece supplies heat. The core contributes metal to the weld. The electrode holder connects one terminal of the source and the work lead completes the welding circuit. A constant-current source helps limit current changes when the welder varies the arc length. Voltage can still vary with arc length.

The Welding Processes and Procedures subject accounts for about 19% of the closed-book exam in CWB Form 301 Appendix A. For an inspection assignment, identify the process before choosing which setup checks matter. A rod placed in an electrode holder and changed as it is consumed points to SMAW. For continuous wire processes you would also check the feeder and applicable gun or head.

Understand the covering

Covering functionWhat it contributesWhat an inspector might check
Shielding gasesProtect the arc and pool from the surrounding atmosphereIdentify the specified electrode and condition
SlagA surface layer helps protect and shape the weld as it coolsConfirm the specified cleaning before the next pass
Arc stabilityConstituents help the process strike and maintain the arcCompare current type and polarity with the electrode information
DeoxidationSome ingredients react with oxygen in the weld systemVerify specified surface preparation even when an electrode tolerates some oxides
Deposit chemistry or rateSome coverings add alloying elements or iron powderCheck the actual package label and specification

Different electrodes use different combinations. A cellulosic covering can produce a forceful arc and fast-freezing slag used in some open-root pipe procedures. Rutile coverings contain titanium dioxide and are often selected for handling and bead shape. A basic low-hydrogen electrode can help control diffusible hydrogen where the specified handling and exposure controls are followed. Do not interchange them because the core wires look alike. TWI on flux-covered electrodes and Lincoln Electric on low-hydrogen electrodes.

Read the specified polarity and progression

With direct current electrode positive (DCEP) the electrode is positive relative to the work. With direct current electrode negative (DCEN) it is negative. Alternating current (AC) changes direction periodically. Coverings are designed for different current types and polarity. For example, a manufacturer's E6010 electrode may be specified for DCEP and an E6012 can be suitable for DCEN. Some low-hydrogen electrodes operate on AC as specified by the manufacturer. Check the product and the particular welding procedure data sheet (WPDS). Heat balance and penetration depend on the process, electrode and settings. A fixed heat split cannot predict them. Miller on stick electrode selection.

Worked inspection. The WPDS calls for a low-hydrogen electrode on DCEP. The setup is using DCEN. Record the equipment polarity, electrode and affected welds and notify the qualified supervisor. Verify the correction and obtain a disposition for any weld deposited under the changed setup. A good-looking bead does not show that the procedure was followed or establish internal fusion.

In a vertical position, progression describes whether welding proceeds up or down. It influences puddle control and the way fusion and slag develop. Some electrode and procedure combinations are intended for one progression. Check the actual travel direction against the WPDS during welding. If a vertical-up procedure was used downhill, record that deviation and ask for disposition. Use the requirements for the actual joint and application.

Observe restarts, slag and arc deflection

Stick welding is portable and the covering supplies the shielding, so the process needs no external gas cylinder at the arc. It still needs the conditions specified for the work. Manual electrode changes require stops and restarts. At those locations, look for incomplete ties, surface porosity or visible residue and verify the prescribed interpass cleaning. Record an arc strike outside the weld zone and apply the project criteria.

When an arc wanders near the end of a steel joint, magnetic arc blow is one possible cause. A DC welding circuit can produce a nonsymmetric magnetic field that deflects the arc. Check for a repeated pattern and the location of the work connection. A qualified person can assess changes such as repositioning the work lead, using a shorter arc or switching to AC where the approved procedure and electrode permit it. Also consider electrode condition and setup before attributing spatter or irregularity to one cause. Lincoln Electric on arc blow.

Loading diagram...
SMAW Arc Zone & Five Functions of the Flux Covering
Test Your Knowledge

A WPDS specifies DCEP for a low-hydrogen electrode. The welder is using DCEN. What is the Level 1 inspection finding?

A

AC has been substituted for DC.

B

Electrode polarity differs from the procedure. Record the deviation and refer affected work for disposition.

C

The setup is acceptable because the voltage display is stable.

D

Testing is unnecessary because polarity cannot affect an arc weld.

Test Your Knowledge

An inspector observes vertical-down stick welding where the WPDS requires vertical-up. What is the correct response?

A

Accept a smooth finished bead.

B

Increase amperage to offset the different progression.

C

Wait to see whether magnetic arc blow occurs.

D

Record the deviation and follow the project hold and disposition process.

Test Your Knowledge
Multi-Select

Which three actions can help address confirmed magnetic arc blow when authorized by the procedure and responsible personnel?

Select all that apply

Use AC if both the electrode and approved procedure permit it.

Lengthen the arc substantially.

Review and reposition the welding work connection as applicable.

Use a shorter arc consistent with the approved technique.

Sections you finish are checked off in the contents.