3.2 Supplementary Symbols: Field Weld, All-Around, Contour, Finishing & Backing

Key Takeaways

  • The flag specifies field welding; the open circle specifies weld-all-around, not both sides of the joint.

  • Under AWS A2.4:2020, a contour symbol without a finishing designator can be achieved by welding or mechanical finishing; U requires mechanical finishing without specifying a method.

  • Melt-through specifies one-sided complete joint penetration with visible root reinforcement.

  • R within the backing symbol calls for removal; a rectangle within the groove symbol can specify a spacer.

  • A backing weld is made before the groove weld; a back weld is made after it.

Last updated: November 2026

Supplementary Symbols: Field Weld, All-Around, Contour, Finishing & Backing

A basic weld symbol identifies a weld type. Supplementary symbols help you distinguish where the weld is made, where it continues, the required face contour, and what is needed at the root. Use AWS A2.4:2020 for the examples below; verify the conventions specified for the work.

Field Weld and Weld-All-Around Symbols

Two high-frequency supplementary symbols sit directly at the junction where the arrow meets the reference line:

1. Field Weld Flag

A flag placed at the arrow-reference-line junction specifies a field weld. That is a location requirement, not a contour or process requirement. Check the erection plan and approved procedure for any limits on weather, access or sequence.

  • Flag orientation: The flag may point either left or right (and upward or downward from the junction) depending on drafter layout. Direction carries zero difference in meaning.
  • Absence of flag: Without a flag, the welding symbol does not specify field welding. Read drawing and project notes before deciding the required location.

2. Weld-All-Around Circle

An open circle at the arrow-reference-line junction specifies a weld all around the indicated set of joints. The symbol can carry the weld across abrupt changes in direction, including changes of plane, where the same symbol applies. On a box section meeting a plate, the weld may continue around the four faces. This does not order a weld on the reverse side of the joint: extent and side significance are separate.

A continuous circumferential weld without an abrupt change in direction, such as a regular pipe girth weld, does not need an all-around symbol under AWS A2.4 Clause 6.11.2. Do not assume a missing circle means an intermittent weld. If a weld is both field-made and all-around, both symbols may be shown at the junction.

Contour Symbols and Finishing Methods

Structural and pressure applications often restrict weld face profile to control stress concentrations, enable Nondestructive Examination (NDE) probe coupling, or allow mating parts to fit cleanly. Contour symbols are placed directly on the outer side of the weld symbol:

  • Flush or flat: A straight line parallel to the reference line indicates the contour. AWS A2.4:2020 uses flat for fillet welds and flush for welds such as groove welds.
  • Convex: Represented by a smooth arc curving away from the weld symbol (bulging outward).
  • Concave: Represented by a smooth arc curving toward the weld symbol (hollowed inward).

The Critical Finishing-Letter Rule

When a specific mechanical finishing method is required to achieve the specified contour, a finishing method letter is placed directly adjacent to the contour symbol:

Finishing LetterRequired MethodTypical Inspection Context
CChippingRemoving gross excess crown or spatter before dressing
GGrindingMost common on structural bridges and dynamically loaded welds; verify grinding marks run parallel to primary stress where specified
HHammeringControlled mechanical peening or dressing when permitted by procedure
MMachiningPrecision bearing surfaces or full flush preparation for ultrasonic scanning
PPlanishingMechanical smoothing when specified
RRollingMechanical finish treatment when specified
UUnspecifiedMechanical finishing is required, using any acceptable method chosen by the fabricator

Read the edition: Under AWS A2.4:2020 Clause 6.13, a contour with no designator can be achieved by welding or mechanical finishing. Earlier wording differed. U means mechanical finishing is required, but the method is unspecified. G identifies grinding. None of those marks gives a numerical surface roughness; check notes and other requirements. For example, a flush groove weld with no finishing letter is not automatically nonconforming because it was ground, provided the work meets the drawing, procedure and applicable requirements.

Melt-Through, Backing, Spacer, and Back/Backing Welds

Several supplementary symbols sit on the opposite side of the reference line from the main groove weld (or straddle the line) to govern root conditions:

Symbol Shape & PositionNameEngineering & Inspection Meaning
Solid black semicircle on opposite sideMelt-throughComplete Joint Penetration (CJP) required from one side with visible root reinforcement protruding on the opposite side; height/contour may be dimensioned
Open semicircle (crescent) on opposite sideBack weld or Backing weldSecondary weld deposited on the root side; sequence on multiple reference lines determines whether it is a backing weld (first, nearest arrow) or back weld (second, after main groove)
Open rectangle on opposite sideBackingBacking bar, strip, or non-fusible backing (ceramic/copper) placed behind the root to support molten metal
Open rectangle containing RRemovable backingBacking material must be completely removed after welding
Rectangle within the groove symbolSpacerCheck the specified material and dimensions in the tail or drawing. With multiple reference lines, the spacer rectangle is on the line nearest the arrow.

Distinguishing Back Weld vs. Backing Weld

The same unfilled symbol can designate either. Read the tail or the reference-line sequence. On a single line without a tail designation, AWS A2.4:2020 Clause 7.7.4 permits either unless another requirement controls:

  1. Backing weld: On a reference line prior to the main groove weld, so it is deposited before the groove weld.
  2. Back weld: Placed on a subsequent reference line farther from the arrow (deposited after the main groove weld).

Nondestructive Examination (NDE) Cross-References

When a fabrication drawing integrates inspection directly into the welding symbol—either via a separate stacked reference line farthest from the arrow or as a dedicated examination symbol—standard NDE letter designations appear on the reference line:

  • VT: Visual Testing
  • MT: Magnetic Particle Testing
  • PT: Liquid Penetrant Testing
  • UT: Ultrasonic Testing
  • RT: Radiographic Testing

Find the method, side (if specified), length or proportion of joint to be examined, and any stated number of locations. Consult the drawing convention, examination procedure and inspection plan before turning a callout into a test instruction. For example, a drawing that calls for an examination of four specified locations is not permission to choose four unrelated joints.

Loading diagram...
Supplementary Symbols at Junction, Contour, and Root
Test Your Knowledge

On an AWS A2.4:2020 drawing, a single-V groove symbol below the reference line has a flush contour with G, and a flag is shown at the arrow junction. What is specified?

A

A shop weld finished flush by unspecified mechanical means

B

A field weld made on the other side and left in the as-welded convex condition

C

A shop weld made all around the perimeter and machined smooth

D

A field weld finished flush by grinding on the arrow side

Test Your Knowledge

Which statement accurately distinguishes a melt-through symbol from a removable backing symbol on a single-bevel groove weld?

A

Melt-through uses an open rectangle with 'R', whereas removable backing uses a solid black semicircle

B

Melt-through uses a solid black semicircle on the opposite side for visible root reinforcement, whereas removable backing uses an open rectangle containing 'R' on the opposite side

C

Both symbols are centered straddling the reference line and remain permanently in place

D

Melt-through indicates an as-welded concave cap, whereas removable backing specifies a spacer bar between root faces

Test Your Knowledge
Matching

Match each supplementary symbol or letter to its exact meaning on a welding drawing.

Match each item on the left with the correct item on the right

1

Open circle at arrow-to-reference-line junction

2

Contour line with the letter U

3

Rectangle within the groove symbol

4

Flush contour line with no finishing letter

Sections you finish are checked off in the contents.