10.2 Duty Cycle, Welding Cables, Work Leads & Parameter Monitoring

Key Takeaways

  • Base duty-cycle decisions on the manufacturer’s rating and its stated conditions.

  • Cable guidance uses the combined electrode and work-lead length, selected current, duty cycle and the equipment instructions.

  • The work lead carries welding current. Protective grounding has a separate safety function.

  • Measure current and voltage at the specified points and identify welding parameters on the correct basis.

Last updated: November 2026

Read the rating at the output used

Duty cycle expresses operating time as a percentage of the specified test interval at a stated output. A manufacturer can rate different outputs differently. For equipment rated at 60% at 300 A in a ten-minute interval, the stated use corresponds to six minutes welding and four minutes cooling as instructed. Use the manufacturer’s ratings or curve for a different output, process or condition. An estimate based on I2RI^2 R heating in one part of the equipment cannot establish its rating. The torch, leads and feeder can have separate limits. Manufacturer rating example and IEC scope for arc welding power-source ratings.

Worked timing check. A power source manual shows 40% at the selected output using ten minutes. Four minutes arc-on leaves six minutes for the cooling period. A work instruction expecting five continuous minutes at that output exceeds that rating. Raise the mismatch for the selected equipment or production method. A routine electrical interruption can leave a stop or crater that must be assessed under the project requirements. The device’s thermal protection is not an operating target.

Follow the complete welding circuit

The electrode lead carries current to the holder or the feeder and gun. The work lead completes the return path through the work. Its job differs from the equipment’s protective grounding. Check where the work connection is attached and whether the intended return path can carry the current. Follow equipment and site instructions for sound contact and routing. Stray current through bearings, rigging or other unintended paths can cause damage and present a hazard. Do not alter electrical connections on energized equipment. CCOHS on welding electrical safety and TWI on safe power-source installation.

For a cable chart that uses total circuit length, combine both leads. A 15 m electrode lead and a 15 m work lead give 30 m. Choose the manufacturer's column for the combined length and duty cycle and its row for the output. A heavier cross-section typically means less resistance for the same conductor material and length. Follow the equipment instructions for cable condition, connections and permissible routing. Report damaged insulation or loose, overheating connections. Miller cable length chart and instructions.

Cable and connection resistance produces a voltage drop consistent with V=IRV=IR under steady current. Resistive heating follows P=I2RP=I^2 R for that resistance. For example, at 280 A, a 4.5 V steady loss across the cable and connection path corresponds to about 4.5/280=0.0161 Ω4.5/280=0.0161\,\Omega. Verify the measurement location and investigate the loss without assigning a weld defect solely from the value.

Verify the actual measurement

QuantityWhat the inspector checks
CurrentUse the suitable range and current type. A clamp sensor normally surrounds one lead carrying the full measured current. Equal opposing currents within it can cancel
VoltageConfirm the reference points and their relation to the arc. A measurement at the output terminals can include cable and connection voltage drops
Travel or wire feed speedVerify travel distance and elapsed time or specified equipment measurement for travel. Follow the equipment’s approved method for checking actual feed rate
Recorded conditionsRecord measurement method and equipment identity, process, pass, readings and timing where required. Waveform-controlled processes can need time-resolved measurement

A steady pass runs at 280 A and 300 mm/min. The source reads 28.0 V and the specified measurement method establishes 23.5 V for the arc. The corresponding simple energy-per-length values are 60(28)(280)/(1000(300))=1.568 kJ/mm60(28)(280)/(1000(300))=1.568\,\text{kJ/mm} using the panel and 60(23.5)(280)/(1000(300))=1.316 kJ/mm60(23.5)(280)/(1000(300))=1.316\,\text{kJ/mm} using the arc value. Compare the result on the required basis with the actual procedure limit. For waveform-controlled welding follow the applicable method. Safety and installation requirements govern where and how qualified people connect instruments. TWI on parameter measurements and CWB procedure preparation.

For a second job, the data sheet specifies a travel speed of 280–320 mm/min. The welder covers 120 mm of joint in 24 s with a steady arc. That is 5 mm/s, or 300 mm/min. Record the result and the measured segment and duration. If the check spans a pause or a restart, use the project’s definition of the measurement interval and identify what was included. A travel-speed pass result cannot establish whether the voltage, current, wire or shielding met their requirements.

Loading diagram...
Trace the voltage measurement across the circuit
Test Your Knowledge

At the selected output the manufacturer specifies a 60% duty cycle using ten minutes. Which arc-on and cooling times does that represent?

A

Six minutes on and six minutes cooling.

B

Six minutes on and four minutes cooling.

C

Four minutes on and six minutes cooling.

D

Ten minutes on and four minutes cooling.

Test Your Knowledge
Fill in the Blank

A cable chart calls for total circuit length. With a 15 m electrode lead and a 15 m work lead, what length in metres should be used?

Type your answer below

Test Your Knowledge
Multi-Select

Which three checks are appropriate for an audit using the manufacturer’s cable and measurement instructions?

Select all that apply

Account for both lead lengths in a total-length cable chart.

Assume the power source terminals always show the voltage across the arc.

Use the prescribed measurement points and record what they represent.

Check that the current sensor is on the specified current path, such as one lead carrying the full current.