5.1 Weld Stress Types, Joint Efficiency & CJP vs. PJP Applications
Key Takeaways
Tension, compression and shear act across different planes. Bending and torsion can make stresses vary across the joint.
For this ideal 90° equal-leg fillet, use leg length divided by the square root of two for the geometric throat.
If the given design uses that throat and supplies effective length, multiply the two to find effective weld area.
CJP and PJP describe penetration through the joint thickness. Verify the specified geometry and the required examination evidence.
Weld toes, terminations and abrupt transitions can concentrate stress. Use the applicable fatigue detail and acceptance rules for the actual work.
Follow the load through the joint
A load path is the route by which forces pass through members and connections. Consider a bracket welded to a column. A load on its projecting end can create shear at the connection and bending that is greater near the column. The stresses at the weld need not have the same orientation as the applied force. Find the weld and use the drawing to identify which edges and faces participate.
| Action | What it tends to do | What to notice in an inspection drawing |
|---|---|---|
| Tension | Pulls a member or joint apart | An abrupt transition or a planar flaw can concentrate tensile stress near its tip |
| Compression | Pushes a member or joint together | Fit can matter where the design transfers load by bearing. A slender member can buckle. |
| Shear | Tries to make one side slide relative to the other | Check where the design assumes the weld transfers force and what length and throat it uses |
| Bending | Produces tension on one side and compression on the other in simple bending | Check changes of section and weld profile in highly stressed regions |
| Torsion | Twists a section and develops shear | Use the full weld group shown by the designer to identify which segments and terminations require inspection |
Several actions can occur together. An inspector checks the specified geometry and criteria. The drawing or engineering authority defines the approved load path. Observing a notch or a discontinuity provides evidence for evaluation under the applicable rules. Its name alone cannot decide whether the detail conforms.
Work out fillet throat area from given inputs
A fillet weld joins intersecting surfaces. For an ideal, flat-faced, equal-leg fillet on a 90° corner with leg length , the right triangle gives geometric throat . In a calculation that uses that throat as effective throat and gives effective length , the effective weld area is:
For a 6 mm equal-leg fillet with a stated 150 mm effective length, the area is . For 5 mm legs over the same effective length, it is about . The area is five-sixths of the previous value, a reduction of approximately 16.7%. A separate reduction in effective length from 150 mm to 135 mm would reduce that area's value by 10% from the size-only case. Carry full precision through the calculation and round the result. Actual design resistance depends on the design rules, load direction, materials and effective dimensions. The geometric calculation does not provide weld acceptance tolerances.
The CWB explanation of fillet weld size illustrates calculating effective area from throat and effective length. Use the governing design rule to choose those dimensions. A visual gauge can compare leg and face geometry with a specified profile. It cannot establish hidden penetration or prove what material was used. CWB explanation of fillet weld size.
Apply the specified penetration detail
Complete joint penetration (CJP) specifies fusion through the joint thickness. Partial joint penetration (PJP) leaves part of the joint thickness outside the intended welded region. The groove depth defines preparation. The required weld size and any qualified penetration allowance are separate matters. These designations alone do not determine resistance or fatigue category.
| Drawing requirement | Inspection approach |
|---|---|
| CJP with a specified two-sided preparation | Identify both sides. Verify any specified backgouging and the required evidence of complete penetration. |
| CJP with a specified single-sided procedure | Check root preparation, backing or open-root details and the specified examination method. |
| PJP with a stated weld size | Verify the dimension called for and the workmanship of the intended welded region. Document any required evidence still pending. |
Example. The same assembly contains a fully penetrated butt splice and a partial-penetration groove along a stiffener. Both faces may look smooth after welding. The butt splice still needs the examination assigned to its CJP detail. On the stiffener a portion intentionally unwelded by design does not by itself fail the PJP requirement. Check the approved drawing and procedure before choosing what to measure or record. CWB Form 101E company certification guide.
Recognize fatigue-sensitive geometry
In fatigue, repeated stress changes can cause a crack to initiate and grow. Load changes need not make the whole member yield. A sharp toe, undercut, abrupt thickness transition or backing crevice can concentrate stress locally. The local effect depends on geometry and loading. For example, a tall crown with a steep toe can create an abrupt surface transition. Additional deposit at the centre does not smooth that transition.
Compare the specific detail and loading category before applying the governing workmanship table. Treat requirements for backing removal, a transition taper, grinding or examination as requirements of the applicable detail. Verify their dimensions, direction and extent where they are specified. If a code clause and a drawing note appear to conflict, preserve the measurement and raise the issue for an authorized disposition. CWB fatigue case examples and FHWA fatigue and fracture reference manual.
For an ideal 90° equal-leg fillet with an 8 mm leg and a stated effective length of 200 mm, use the geometric throat as effective throat. What is the effective area to the nearest square millimetre?
1,600 mm2
800 mm2
1,131 mm2
566 mm2
Which three checks are appropriate when a drawing designates a welded detail as fatigue-sensitive?
Select all that apply
Identify the applicable acceptance criteria for the specific detail and loading category.
Use a single static undercut limit for all welded details.
Verify the required toe profile and any specified transitions or grinding.
Determine the backing requirement from the approved detail and verify it during the assigned inspection.
Why can a tall weld crown with a steep toe reduce fatigue resistance at the toe?
It lowers the tensile strength of the filler metal below the base metal
The steep toe creates an abrupt transition and increases local stress.
It converts transverse tension into pure torsion along the weld axis
It eliminates the effective throat of the groove weld
Sections you finish are checked off in the contents.