9.2 Nonconformance Reports (NCRs), Document Control & Tool Calibration

Key Takeaways

  • An objective nonconformance report identifies the item, stated requirement, actual evidence and containment status.

  • The disposition and its authority come from the governing requirements and project quality procedure.

  • Use the current authorized document at the point of inspection. Keep enough revision and item information to trace a decision.

  • Remove an unsuitable instrument from use and assess whether past decisions could have been affected.

Last updated: November 2026

Write a report that can be checked

A nonconformance is a failure to fulfil a requirement. A nonconformance report (NCR) gives the evidence, identifies the affected item and assigns it to the project’s disposition process. Record the report ID and date, the assembly and weld ID or location, the controlled source of the requirement, the measured or observed condition with units, and the status of any containment. Photographs, readings or gauge IDs may help another reviewer reproduce the finding. Use the project’s rule for tagging or holding affected work and notify the designated supervisor. ISO and IAF on documenting nonconformity and CSA W178.2:18 clause 6.

Example. Drawing S-204 revision 3 and its project acceptance note require a minimum 6.0 mm fillet leg at W-08. The measured leg is 4.5 mm over the noted segment. The recorded shortfall is 1.5 mm. Enter the segment limits, the instrument used and the actual reading. Avoid assigning a cause such as “welder rushed” without evidence. Advise the designated person if the assembly is scheduled to be coated before the review.

Route the disposition and check closure

Possible outcomeMeaning in this context
ReworkBring the item into conformity with the original requirement using authorized work instructions
RepairMake the item acceptable for intended use under an approved disposition. Remaining departures can require a concession
Concession or use as isObtain authorization to accept the defined departure only where the applicable rules permit it
Reject or scrapPrevent the item from being accepted for the specified use and follow the required disposition process

Know who can approve each outcome under the contract and governing code. An inspector’s observation does not authorize a waiver of a requirement. When a repair or rework is authorized, link revised instructions, any additional inspection and its results to the NCR. Close the record only after the applicable review and evidence are complete. ISO technical committee vocabulary for rework, repair and concession.

A correction addresses the detected issue. Corrective action addresses the cause to prevent recurrence. Reworking an undersized weld under the approved disposition corrects the item. Finding that an obsolete drawing was issued at two stations, fixing the distribution process and checking the next revision's rollout addresses recurrence. Document follow-up evidence. Prevention can also be built into controls, such as verifying access to the next drawing revision before production. ISO and IAF on reviewing a response.

Keep documents and measuring tools fit for use

Compare the drawing and procedure revisions at the point of use with the authorized issue record. If two copies conflict, confirm which applies, prevent continued use of the obsolete working copy, and identify work made against it. Retain records as required. The project decides whether the release label is “Issued for Construction” or a different designation. The current approved requirements and dated records form the audit trail. ISO on documented information.

For example, a traveler lists W-08 as welded before revision 3 was issued, but W-09 was welded after the change. Compare each weld with the revision that actually applied and flag any work that may be affected. Record the evidence behind the date and scope decision before closing the document discrepancy.

For an instrument, check its identification, condition, range, resolution and required calibration or verification status. Match the method to the decision. An in-date gauge with a bent pointer is unsuitable. An infrared thermometer set for the wrong surface can mislead even with a calibration record. Metrological traceability depends on a documented calibration chain with suitable uncertainty. Provide the instrument identification and the valid reference or verification records required for the task. ISO guidance on monitoring and measuring resources and National Research Council Canada instrument calibration policies.

Worked instrument case. A contact pyrometer is compared at the relevant range and shows a high bias of about 35 °C relative to a valid reference. A recorded 160 °C against a 150 °C minimum might have represented only 125 °C if the bias applied at that earlier time. Remove the tool from use and notify supervision. Review the affected uses, the likely period and size of the error, and any independent records. Do not rewrite or dismiss prior results using a guessed correction. The authorized review decides which measurements require validation, re-examination or other disposition.

Loading diagram...
Resolve an unsuitable instrument or a documented deviation
Test Your Knowledge

A weld falls below an explicit project minimum. The foreman requests acceptance without physical changes. What would establish such a disposition if it is permitted?

A

A recorded concession from the authority designated by the governing requirements.

B

An oral waiver from the welder who completed the joint.

C

A rework instruction without actual rework.

D

The inspector’s belief that the load is small.

Test Your Knowledge

A pyrometer used to check minimum preheat reads about 35 °C high in a valid comparison at the working range. What should the inspector do?

A

Use it and apply a guessed correction.

B

Review future measurements only.

C

Remove it from use, notify supervision and review whether earlier decisions could have been affected.

D

Replace all recorded temperatures with the specified minimum.

Test Your Knowledge
Multi-Select

Which three records or actions support a traceable response to an undersized weld?

Select all that apply

Record the item, observed dimension and applicable controlled requirement.

Replace the NCR with an opinion about the welder.

Identify which document revision applied and preserve the evidence.

Record the approved disposition and any required verification results.

Sections you finish are checked off in the contents.