4.2 Groove Weld Dimensions: Depth of Bevel, Effective Throat, CJP & PJP
Key Takeaways
In AWS A2.4:2020, D gives groove depth and (S) gives groove weld size. Both can appear together on the left.
Root opening goes inside the groove symbol. Groove angle appears above or below the symbol as appropriate.
Omitting both depth and size generally calls for complete penetration under the AWS groove rule. Check provisions for special configurations.
A partial joint penetration weld can have an intentionally unwelded portion. Verify the required size and workmanship in the intended welded portion.
Read length to the right. For intermittent groove welds, pitch is the centre-to-centre spacing between adjacent segments on one side.
Separate the dimensions of an AWS callout
A groove symbol describes the shape of the opening. Its dimensions say how much material to prepare, what weld size to achieve and how far along the joint the weld extends. These examples use AWS A2.4:2020 clause 7. Identify the units in the drawing before working with its dimensions.
| Position | Meaning | Inspection question |
|---|---|---|
| Unparenthesized value at left, D | Groove depth | Is the preparation depth correct? |
| Parenthesized value at left, (S) | Groove weld size | What size does the design require in the completed weld? |
| Inside the groove symbol | Root opening | What gap is required before welding? |
| Above or below the groove symbol as appropriate | Included groove angle | Do the prepared faces form the required angle? |
| Right of the symbol | Length, followed by pitch after a hyphen for intermittent welds | What extent or spacing is required? |
For a single groove, place the dimensions on the same side of the reference line as the symbol. Each groove in a double groove can have its own dimensions. The root opening can be specified once for both sides. For U and J preparations, find the radius and root face in a referenced detail or other drawing information.
Read size and preparation independently
Example. On a metric drawing the single-bevel symbol is below the line. It shows 12(10), a 2 mm root opening and a 45° groove angle. Prepare a 12 mm groove and achieve a 10 mm groove weld size. Verify the 2 mm opening and the 45° angle before welding. The callout applies to the arrow side. The two left-hand numbers differ by 2 mm because of the dimensions chosen on this drawing. For another joint, follow its requirements for size, depth and tolerances.
A second drawing gives (8) for a flare-bevel. The required groove weld size is 8 mm. Find the physical preparation in the detail. Clause 7.2.10 defines groove depth in the flare using the point of tangency and the top of the member. It measures the size from the outside surface. That size value alone does not specify that a bevel must be machined on the rounded member.
When the callout leaves a dimension out
- Parenthesized size alone supplies the required size. Find the geometry in the drawing or referenced procedure as applicable.
- An unparenthesized dimension on the left gives depth. Read a referenced weld size if one is supplied. If size is specified neither on the symbol nor elsewhere, the AWS rule requires size at least equal to groove depth.
- Square grooves have no applicable preparation depth in this notation.
- Omitting both depth and size under the general groove rule calls for a weld through the joint thickness. Read the particular provisions for flare configurations.
- The tail can specify CJP with the weld symbol omitted if the designer permits optional joint geometry. Check the approved procedure for the preparation that will be used.
Decide what evidence demonstrates penetration
Complete joint penetration (CJP) describes fusion through the joint thickness. Partial joint penetration (PJP) describes a design where the welded region does not extend through that thickness. A PJP detail can still require fusion to the intended joint faces and compliance with a specified size. An intentional unwelded portion can be compatible with the detail. A clean face alone cannot demonstrate what was fused inside.
For a CJP assignment, confirm the procedure and fit-up first. If the procedure calls for welding from two sides and backgouging, coordinate the assigned inspection of the excavation before it is covered. When accessible melt-through is specified, check the exposed root and compare with its acceptance requirements. Determine what examination can demonstrate the specified penetration for the joint.
For PJP, identify the portion meant to be welded. Check the visible profile against applicable limits and review any additional evidence called for by the inspection plan. A raised cap cannot compensate for insufficient groove weld size. Record the result against the correct weld number, and identify any required examination still pending.
Determine extent
A length on the right applies to the specified weld region. A full-length groove between abrupt direction changes can omit the length. Locate separately dimensioned limits on the view, in a detail or in hatching. For a 75-200 intermittent groove weld, the segments are 75 mm long and the centres are 200 mm apart, leaving 125 mm clear space. Opposed symbols show chain spacing. Offset symbols show a staggered arrangement. Read the construction standard and project documents for authorization and limits. CWB Form 101E, company certification guide illustrates how to identify joint configurations and welding procedure variables.
A metric AWS single-V groove symbol below the reference line shows 16(14) on the left, 3 inside, a 60° angle and 250 on the right. What does it specify?
16 mm groove depth, 14 mm weld size, 3 mm root opening, 60° included angle and 250 mm weld length on the arrow side.
16 mm weld size, 14 mm root face, 3 mm groove depth, 60° per bevel and 250 mm pitch.
16 mm plate thickness, 14 mm reinforcement, 3 mm backgouge, 60° groove angle and 250 mm on the other side.
16 mm length, 14 mm preparation depth, 3 mm weld size, 60° included angle and 250 mm pitch.
A drawing calls for an 11 mm partial joint penetration groove weld. The back is visibly unwelded where the design intends it to be. How do you decide conformance?
Apply a complete penetration requirement to the weld.
Order a back weld whenever the reverse side is visible.
Use the specified size, procedure and inspection requirements to evaluate the intended welded region.
Add cap height to groove depth as proof of fusion.
An AWS A2.4:2020 metric flare-bevel symbol displays (8) to the left. What groove weld size in millimetres is specified?
Type your answer below
Sections you finish are checked off in the contents.