3.4 Intermittent Fillet Welds: Length, Pitch, Chain & Staggered Patterns
Key Takeaways
On intermittent fillet symbols, the two numbers to the right of the triangle (such as 50-150) specify weld increment length first (50 mm) followed by center-to-center pitch (150 mm).
Pitch is always measured center-to-center between adjacent weld increments, never as the unwelded clear gap; clear gap equals pitch minus length (150 - 50 = 100 mm).
Chain intermittent fillets have opposite triangles on the reference line; staggered intermittent fillets offset them to indicate the offset segments on the two sides.
Apply the stated end dimensions and extra end-weld callouts; a length–pitch symbol alone does not require a segment to touch both ends.
When controlling drawing information is missing, document the ambiguity and use the project’s hold and clarification process.
Intermittent Fillet Welds: Length, Pitch, Chain & Staggered Patterns
When the designer specifies welds at intervals rather than a continuous length, the drawing shows intermittent fillet welds (short weld segments separated by unwelded spaces). For the same joint and weld size, depositing shorter lengths can reduce the amount of filler and heat used. Do not substitute an intermittent weld for a continuous weld without authorization. For a CWB Welding Inspector, verifying that weld segment lengths, center-to-center spacing, and layout patterns match the drawing is a core Level 1 competency.
Length and Pitch Dimensions
When a fillet weld is intermittent, two dimensions separated by a hyphen appear to the right of the fillet triangle—for example, 50-150 on a metric drawing using AWS A2.4 (with leg size, say 6, remaining on the left):
- First number (
50): Length () of each individual weld increment (50 mm). - Second number (
150): Pitch ()—the center-to-center distance between adjacent weld increments on the same side of the joint (150 mm).
Why Pitch Is Center-to-Center (Not Clear Gap)
One of the most frequent shop-floor and exam errors is treating pitch as the open gap between welds. Pitch is NEVER the clear gap. Instead, the unwelded clear space between the end of one weld increment and the start of the next is calculated as:
Using 50-150 as a worked example:
- Each weld segment is 50 mm long.
- Center-to-center spacing (pitch) is 150 mm.
- Unwelded clear gap = .
- For an interior repeating interval, the deposited length is of each pitch. End allowances can make the fraction over the whole joint different.
If someone misreads 150 mm as a clear gap, the resulting pitch is , and coverage per repeating interval is . The joint no longer matches the pitch requirement. Do not extrapolate a percentage change in weld length into a percentage change in connection capacity. Check the specified segment size and minimum length for the actual work.
Chain vs. Staggered Intermittent Fillet Welds
When both sides of a T-joint receive intermittent fillet welds, the welding symbol shows fillet triangles both above and below the reference line, and their horizontal positioning along the reference line defines the pattern:
| Feature | Chain Intermittent Fillets | Staggered Intermittent Fillets |
|---|---|---|
| Symbol Appearance | Triangles below and above the reference line sit directly opposite each other vertically | Triangles below and above the reference line are offset laterally (one shifted right or left of the other) |
| Physical Weld Layout | Weld increments on both sides lie directly across the web plate from one another | The segments on the two sides are offset rather than paired at the same station |
| Typical Callout | 6 on left, 50-150 on right (both sides, triangles stacked directly opposite) | 6 on left, 50-150 on right (both sides, triangles horizontally offset) |
| Center-to-Center Offset Between Sides | 0 mm (coincident centers across the plate) | 75 mm for this symmetric, equal-pitch example |
| Inspection check | Look for pairs at the same station across the joint. | Compare the other side’s set-out to the specified offset. |
Note that for a staggered 50-150 pattern, the pitch on each individual side is still 150 mm center-to-center; for symmetric staggering with those equal pitches, the opposing centres are 75 mm apart. Use the drawing for the actual end set-out.
Combining Continuous and Intermittent Welds
The design can specify continuous welds in one region and intermittent welds in another. Look for limits and distinct callouts rather than applying one pattern to the whole joint:
- Different patterns on opposite sides: For example, a continuous
6 mmfillet on the arrow side (no length/pitch to the right of the lower triangle) paired with an intermittent6 mm50-150fillet on the other side (upper triangle). - Continuous end welds transitioning to intermittent middle welds: A drawing might specify continuous fillets at each end of a stiffener or flange (e.g.,
150 mmcontinuous at both ends) with50-150intermittent increments across the middle span. On drawings, this is communicated with separate welding symbols and dimensioned limits or with hatching and dimension lines.
Practical Layout Check: Counting Increments Along a Stiffener
Under AWS A2.4:2020 Clause 8.4.5, unless specified otherwise, the unwelded ends of an intermittent joint cannot be longer than its unwelded spacing between segments. This does not require segments to touch both ends. Additional end welds or specific unwelded end lengths are called out separately.
For a drawing that explicitly sets the outer segments flush to both ends of a 950 mm stiffener using 50–150 chain fillets, seven 50 mm welds separated by six 100 mm clear gaps sum to exactly (six center-to-center pitches of 150 mm spanning 900 mm between the centers of the outer welds, plus half a segment at each end). If the two ends were specified differently, the set-out could change. Verify any end detail such as a returned weld separately from the length–pitch notation.
Handling Incomplete or Ambiguous Symbols
Real fabrication drawings occasionally contain drafting omissions or conflicting callouts—for instance:
- A fillet symbol showing a pitch without a segment length (e.g.,
-150) - An intermittent symbol missing a size that is not stated in the notes or other controlling details
- An unequal-leg callout whose leg orientation is unclear even after checking other details
- A symbol specifying
50-150while a detail view dimensions a100 mmsegment length
A CWB Welding Inspector must NEVER guess or improvise when encountering an incomplete or ambiguous symbol. When an intermittent callout is incomplete, never assume a missing segment length means "weld continuously," never assume an equal-leg size, and never invent an arbitrary increment length to keep production moving. Instead:
- Flag the affected detail and follow the project’s requirements for a hold.
- Document the exact discrepancy (drawing number, detail, grid line, and symbol deficiency).
- Seek written clarification through the designated supervisor and Request for Information (RFI) process.
- Check the written resolution before the designated party releases the joint.
Source: AWS A2.4:2020, Clauses 6.10 and 8.3–8.4 and Figure 8.2.
On an AWS A2.4:2020 drawing, a fillet triangle below the reference line has 6 on the left and 50–150 on the right, in millimetres. What is the clear gap between consecutive segments?
100 mm
50 mm
150 mm
200 mm
How does an AWS A2.4:2020 symbol distinguish staggered intermittent fillets from chain intermittent fillets?
Staggered fillets use a broken arrow, whereas chain fillets use a straight arrow
Staggered fillets place 'STAG' inside the backing rectangle, whereas chain fillets omit the rectangle
Staggered fillets offset the arrow-side and other-side triangles laterally along the reference line, whereas chain fillets place them directly opposite one another
Staggered fillets place the pitch before the hyphen and the weld length after the hyphen
After checking the controlled drawing and notes, you cannot find the length for a pitch-only intermittent symbol or an orientation for an ambiguous unequal-leg fillet. Which two actions are appropriate?
Select all that apply
Instruct the welder to deposit a continuous 6 mm fillet weld until further notice
Flag the affected joint and follow the project procedure to pause release while engineering clarifies it.
Assume a standard 50 mm segment length and place the 10 mm leg on the thicker plate
Document the drawing sheet, detail, and missing symbol parameters before obtaining written engineering clarification
Sections you finish are checked off in the contents.