6.3 Flux-Cored Arc Welding (FCAW-G & FCAW-S) & Submerged Arc Welding (SAW)

Key Takeaways

  • Gas-shielded FCAW uses a flux-cored wire with external gas. Self-shielded FCAW uses the wire formulation for shielding without a separate gas supply.

  • Match polarity, wire, contact-tip-to-work distance and applicable gas to the approved procedure.

  • Submerged arc welding keeps the arc under granular flux, which produces a protective slag.

  • Match the specified SAW wire and flux, verify handling and fit-up, and document any deviation.

  • Confirm the inspection and protection required for the process and configuration in use.

Last updated: November 2026

Read the shielding arrangement

Flux-cored arc welding (FCAW) continuously feeds a tubular electrode whose core contains ingredients that assist shielding, form slag or influence the deposit. It is commonly run from a constant-voltage power source. Depending on the electrode class and approved procedure, it can serve different joint positions and applications.

SetupShielding sourceWhat to verify before the weld
FCAW-G, gas-shieldedFlux contributes slag and an external gas protects the arc and poolWire identification, required gas, delivery at the joint, polarity and approved setup
FCAW-S, self-shieldedThe electrode formulation provides shielding and slag without an external gas supplyCorrect wire, required current type and polarity, extension or tip-to-work distance and permitted conditions
SAW, submerged arcGranular flux covers the arc. Some flux melts and forms slag.Specified combination of wire and flux, condition of flux, fit-up and flux retention

Self-shielded wire can be suitable for outdoor fabrication where protecting an externally supplied gas shield is difficult. Its use does not guarantee that any wind conditions are permitted. Check the actual procedure and electrode data. Different wires can use different polarity. Lincoln Electric on self-shielded and gas-shielded flux-cored electrodes.

Check tip-to-work distance, extension and interpass condition

Contact-tip-to-work distance (CTWD) is the distance from the electrical contact tip to the work. Electrode extension measures the unmelted wire beyond the tip, so the terms differ when an arc is present. Current passing through the extension resistively heats it. A change in extension can affect operating current, melting rate and arc behaviour. The effect depends on the power source and wire. Compare the recorded setting with the required limits for the selected consumable and setup.

On multi-pass flux-cored work, check the required cleaning of slag and the condition of the previous pass before it is covered. Inspect particular locations such as toes and narrow regions of a groove, where material can remain. If slag remains after the assigned cleaning, record the result and arrange a correction in accordance with the approved procedure.

Worked inspection. An outdoor crew intends to use a self-shielded wire. Its feeder contains a gas-shielded wire from the preceding job. The previous setup's polarity may not be correct for the self-shielded wire, either. Verify the spool label, procedure, current settings and physical setup. The tubular shape of both consumables is insufficient to identify their shielding requirements.

Recognize submerged arc welding

Submerged arc welding (SAW) uses a continuous electrode beneath granular flux deposited over the joint. The arc is normally hidden by the flux layer. The flux contributes shielding and slag. Wire and flux together influence deposit chemistry and properties. Verify the combination specified for the work. A matching name on the wire spool does not authorize an arbitrary flux.

SAW is often mechanized. Flat grooves and flat or horizontal fillets are common because gravity helps retain the flux and support the fluid pool. A rotating vessel can bring its seam into a suitable working position during welding. The actual positional range depends on the procedure and equipment. A multi-wire system can distribute the work between arcs, but verify each electrode, speed and electrical setting. Do not assume that all tandem systems use the same polarity or arc arrangement. A covered arc still requires the specified exposure controls. TWI on submerged arc welding.

Monitor SAW setup and condition

  1. Identify both consumables. Match the electrode and flux to the welding procedure data sheet (WPDS) and identify their applicable classification or combination.
  2. Confirm flux handling. Apply product and procedure instructions for storage, drying or recovery. Put aside flux with uncertain condition until it is resolved. Recovered unfused flux and fused slag are distinct materials.
  3. Verify the joint. Compare the root gap, alignment and any backing or initial pass with the WPDS. A gap greater than permitted can contribute to root problems and needs disposition.
  4. Inspect as assigned. Arrange observations before welding, during operation and after slag removal. Record the conditions visible and accessible at each stage.

If an operator finds damp flux in a hopper and a root gap beyond the procedure limit, record the two deviations separately. Correcting one leaves the other unresolved. The effects on a specific weld depend on the consumables, joint and settings. TWI on SAW consumables and CWB Form 101E company certification guide.

Loading diagram...
Shielding Architecture Comparison: FCAW-G, FCAW-S, and SAW
Test Your Knowledge

Which continuous-wire arc process uses a tubular wire designed to supply shielding without a gas cylinder at the arc?

A

Gas-shielded flux-cored arc welding.

B

Self-shielded flux-cored arc welding. Verify the approved wire and setup.

C

Gas-shielded metal-cored arc welding.

D

Submerged arc welding without granular flux.

Test Your Knowledge

The SAW procedure calls for dry flux, a root gap from 0 to 2 mm and a backing strip. You find damp flux, a 3 mm gap and no backing. What is the correct inspection response?

A

Record the flux, gap and backing deviations and obtain disposition before release.

B

Continue if the flux covers the arc.

C

Release the work after adding more wire feed speed.

D

Check only the final surface because all three conditions become irrelevant after solidification.

Test Your Knowledge
Matching

Match each process configuration on the left to its defining operational characteristic on the right.

Match each item on the left with the correct item on the right

1

Gas-shielded FCAW

2

Self-shielded FCAW

3

Single-wire SAW

4

Tandem SAW

Sections you finish are checked off in the contents.