12.1 Visual Inspection Concepts, Lighting, Viewing Angles & Weld Gauges (VICT-301)

Key Takeaways

  • Use the stated inspection procedure to establish light, access, view and equipment requirements.

  • CWB Form 455 records near vision for application and renewal. Its test distance is distinct from production viewing distance.

  • Choose a gauge for the required dimension and use the manufacturer’s reference surfaces and scale.

  • Record what the inspection actually covered. The CWB practical requires single metric measurements.

Last updated: November 2026

Separate the vision record from the test setup

CWB Form 455E/2026-01 records near vision for new applications and renewal. It specifies reading Jaeger number 1, Times Roman N 4.5, or equivalent letters 1.6 mm high at a distance of at least 30 cm with one or both eyes, with or without correction. The form requires the examination to be within 12 months of receipt by CWB. It records whether correction was needed. Follow the correction and vision requirements for the inspection assignment. The form does not set an eye-to-weld distance or a production lighting requirement. CWB Form 455E.

Set up viewing conditions for the assigned examination

Identify the surface and extent to inspect, when it will be accessible and the specified condition. Clean or expose the area by the approved method. Provide suitable light and access. Determine how you can see the root or opposite face when it is in scope. Use the required direct or remote method before work hides the area.

For an explicit example, ISO 17637:2016 clause 4 uses a minimum white-light illuminance of 350 lux at the inspection surface, with 500 lux recommended. Tinted goggles increase the required minimum. When using its direct method, access must allow the eye to be within 600 mm of the surface at an angle of at least 30°. The standard provides for considering remote means such as a mirror, borescope or camera when the direct viewing access is unavailable or the application standard specifies remote inspection. Use the actual requirements for the job. ISO 17637 scope and ISO-authored clause 4 source copy.

Worked setup. A job invokes those ISO direct conditions, with no tinted goggles or stricter project requirement. At a point 550 mm away, visibility is adequate and the direct setup gives a 35° viewing angle and 420 lux. The dimensions and illuminance satisfy those stated minima, including that 420 exceeds 350 by 70 lux. The 500 lux recommendation remains useful when optimizing visibility. A glare patch that obscures the surface still has to be dealt with. Change the light direction or viewing position within the required conditions. Oblique illumination can reveal profile changes. It is the eye’s angle to the surface that governs direct viewing in the stated example.

Match the instrument to the surface

ToolWhat to verify with an appropriate design
Fillet gaugeLeg size or a profile/throat check using its designated feature. Check both legs or other parameters when required
Bridge cam gaugeBevel, reinforcement, undercut depth or other listed dimensions using the appropriate edge and scale
V-WAC gaugeA pointed depth probe or pore size comparison, if present on the model. Its references do not set permissible pore size
Internal hi-lo gaugeOffset across pipe walls and root opening on designs that provide both functions
Taper gauge or ruleAn opening with a suitable taper gauge, or length and spacing with a rule
Mirror, borescope or cameraExamine the authorized surface with adequate coverage and verified image quality where required

Use clean reference surfaces and the actual instrument instructions. Check for wear, correct units and adequate resolution. A gauge used for a different function may need to sit on different surfaces. Measuring a fillet’s visible legs and face cannot establish subsurface fusion or credited penetration. Gal Gage bridge cam guide, V-WAC gauge, hi-lo guide and AWS on fillet gauge and profile checks.

Record the value and where it was taken

For an undercut check, use the depth scale with the gauge referenced to the adjacent suitable base surface. In a reading exercise the pointer is three 0.5 mm intervals below that reference. The depth is 1.5 mm. Record the joint, location and instrument with the reading. To classify the condition, compare the value and any required length or location information with the governing requirement.

For CWB practical samples, the official instructions require single metric values where measurement is requested. The exam’s Generic Welding Standard supplies the sample criteria. Its cut-end exclusion for visual interpretation is distinct from dimensional inspection of both ends. Report production measurements using the job’s method, resolution and acceptance criteria. CWB practical instructions and GWS.

Loading diagram...
Prepare to examine and report a visible surface
Test Your Knowledge

A procedure invokes ISO 17637:2016 clause 4 for direct viewing with no tinted goggles or stricter requirement. What conditions does it specify or recommend?

A

At least 350 lux, with 500 lux recommended, within 600 mm and at least 30° to the surface.

B

At least 350 lux, within 900 mm and at least 10° to the surface.

C

At least 1,000 lux and exactly 90° regardless of access.

D

At least 500 lux in every case with no access limits.

Test Your Knowledge
Matching

Match each task to an appropriate tool for the stated measurement.

Match each item on the left with the correct item on the right

1

Determine toe undercut depth from the adjacent plate

2

Compare a pore with a known size reference

3

Measure inside wall mismatch at a prepared pipe joint

4

Measure a groove opening with a graduated wedge

Test Your Knowledge

The required depth measurement is three intervals from zero on a 0.5 mm scale. What single value should the CWB practical response show?

A

0.5 mm

B

1–2 mm

C

1.5 mm

D

3 mm

Sections you finish are checked off in the contents.