1.3 Tubing Selection, Bending, Fittings & Layout

Key Takeaways

  • Specify instrumentation tubing by outside diameter, wall thickness and material. Check the tube, fitting and other components at the actual temperature and pressure.

  • Prepare a square, deburred cut so the tube can seat fully and the ferrules can seal against an undamaged surface.

  • A radiused bend is shorter along its centerline than two legs measured to the imaginary sharp corner. Use the bender’s marking and gain instructions.

  • For the cited Swagelok gaugeable fitting, 1/4-inch tube uses 1¼ turns on ordinary initial assembly. The small-size exception stops at 3/16 inch.

  • Follow the tubing hookup, layout and support requirements. Use initial-assembly and reassembly instructions for the actual fitting type.

Last updated: November 2026

Select the tube, fitting and route together

NCCER modules 12111 and 12302 cover tubing selection, preparation, bending, joining and layout. Instrument tubing is commonly ordered by outside diameter (OD), wall thickness and material. Pipe may be specified by nominal pipe size and schedule. Verify the actual outside diameter, wall and end connection before choosing tooling or a fitting. Similar outside dimensions can occur in incompatible inch and metric fittings.

The tubing and fitting selection depends on the fluid, design pressure and temperature, installation environment, compatibility and cleanliness. The Swagelok tubing data sheet lists tested wall ranges, allowable working-pressure tables and temperature factors for specific tubing. Some listed stainless tubing can be seamless or welded and drawn. The specified anneal, hardness, condition and dimensions matter to the fitting’s grip and seal. Use the applicable code and design data for the complete assembly. A tube-only rating cannot establish the working pressure of the fittings, valves or adapters in the same run.

Transfer an installation sketch to a bend plan

Start with the approved pickup, termination and support locations. Sketch the run with directions, elevations and written dimensions, using the pipe isometric and instrument hookup for references. Mark joints and supports and show clearance for wrenches and for planned movement. Verify what the dimensions refer to: port face, inserted tube end, centerline or bend vertex. A dimension from one face to another cannot be transferred to a bend mark until you account for the fitting insertion and the bender’s reference convention.

  • In a one-plane offset between parallel runs, an ideal centerline sketch gives diagonal travel as offset divided by the sine of the bend angle. For a 3-inch offset with two 30° bends, the diagonal vertex spacing is 3 ÷ 0.5 = 6 inches. For the cited hand bender, the offset table gives the same result using its bend-mark convention.
  • For a single 90° bend with a 1-inch centerline radius, the two ideal sharp segments removed from the corner total 2 inches. The replacement quarter-circle is π × 1 in ÷ 2 ≈ 1.571 inches. The gain is about 0.429 inch. This is a length correction for that geometry. Use the tool’s marking instructions, which can reference the projected intersection of the two legs rather than the tangent point.
  • Check bends in the correct plane and verify the final angle after releasing the tool. Springback varies with angle, radius, material and wall. The Swagelok hand bender manual describes verifying the finished bend and using its angle marks, offsets and gain calculations.

Fit the tubing to the equipment without pulling it into alignment with the nut. Provide supports using the approved location and spacing for the system. For an impulse line, prevent unwanted liquid pockets in gas service or gas pockets in liquid service. The Rosemount 3051S manual gives a model-specific example: in liquid service the impulse line slopes up from transmitter to process, in gas service it slopes down toward the process, and in steam service the below-tap mounting keeps the impulse pipes condensate filled. Use the process hookup for the actual orientation, routing and any required fill or condensate arrangement.

Cut, deburr and inspect before fitting

Use a sharp tube cutter or suitable saw and guide to make a square cut. Apply gradual feed to avoid deforming the end. Remove inside and outside burrs and clean out chips using the approved procedure. Inspect the sealing area for scratches, flattened regions or distortion before installation. A turn count cannot compensate for a damaged sealing surface or a tube stopped short of the body shoulder.

Assemble the fitting that is specified

In the Swagelok gaugeable two-ferrule design, the front ferrule seals against the tube and body, and the back ferrule grips the tube. Use matching components from the specified system and confirm the fitting’s assembly instructions.

OperationWhat to check on the cited fitting family
Ordinary initial assembly of a new 1/4-inch fittingSeat the tube against the body shoulder, finger-tighten the nut, mark it at 6 o’clock and hold the body. The specified pull-up is 1¼ turns, ending at 9 o’clock.
Initial assembly of the small inch sizesThe catalog gives a ¾-turn exception for 1/16, 1/8 and 3/16 inch. It gives separate instructions for metric exceptions and for special installations.
Initial inspectionThe matching gap gauge should not enter the gap at a properly pulled-up initial joint. If it fits, the fitting requires additional pull-up according to the catalog. Pressure or leak testing follows the applicable plan.
ReassemblyVerify pressure isolation before disassembly. Mark the original pulled-up position, reseat the preswaged tube, return to the marks and tighten slightly per the manufacturer. The initial gap gauge has no reassembly function.

For example, a 1/4-inch tube sitting short of the shoulder is a seating problem. Correct it before pull-up instead of trying to recover the assembly by turning the nut farther. A larger fitting, different fitting system or critical-service preparation may need a different procedure.

Distinguish a tapered-thread joint from a tube fitting

National Pipe Taper (NPT) identifies a tapered thread. The design determines the approved thread sealant, clearance and assembly procedure. For its PTFE thread tape, Swagelok specifies clean male tapered threads, winding in the direction of the thread spiral from the first thread without overhanging that thread, and 2–3 revolutions. The tape instructions exclude tube-fitting, flare and cone ends. These joints use their own sealing surfaces. Keep sealant out of flow paths where loose material could obstruct an instrument.

Sources checked November 16, 2026. NCCER instrumentation curriculum, Swagelok tube data, Swagelok hand bender, Swagelok fitting catalog, p. 70, Rosemount 3051S reference manual.

Test Your Knowledge

For ordinary initial assembly of a new 1/4-inch Swagelok gaugeable two-ferrule tube fitting, how far is the nut pulled up after the tube is seated and the nut is finger-tight?

A

¾ turn

B

½ turn

C

1¼ turns

D

2 turns

Test Your Knowledge

Which statement describes the two ferrules in the cited Swagelok fitting?

A

The rear ferrule makes the primary seal against the fitting body.

B

The front ferrule seals at the body and tube, and the back ferrule grips the tube.

C

Both ferrules have the same shape and may be interchanged.

D

The nut threads are sealed by the back ferrule to contain process pressure.

Test Your Knowledge

How do the cited Swagelok PTFE tape directions treat the end of a male tapered pipe thread?

A

Wrap in the thread-spiral direction without extending tape past the first thread.

B

Wrap against the thread direction and leave tape projecting into the bore.

C

Cover the ferrules and tube OD as well as the threads.

D

Apply tape to both the front ferrule and the female fitting seat.

Test Your Knowledge

A pair of 30-degree bends will produce a 3-inch offset in the plane of the run. The specified bender uses a 2.000 offset allowance at 30 degrees. What is the required mark spacing?

A

1.5 inches

B

3.0 inches

C

4.5 inches

D

6.0 inches