11.3 Tower Crane Deductions & Net Capacity Verification
Key Takeaways
Identify what the manufacturer rating already includes before deducting blocks, rope allowances, rigging or attachments.
Compare the chart rating with demand on the same basis, and keep the actual load on the hoist and the accessory limits as separate checks.
Repeat the comparison for each relevant radius, reeving and rigging condition along the route.
A tower crane's load moment and line pull limiting devices enforce different constraints. Their presence does not replace planning or chart verification.
Use the rating's load convention
Read the chart notes and equipment manual for the particular crane, configuration and hoist. The full load on a hook includes the item and the gear attached to it. A chart can express capacity on a different accounting basis because it already includes designated equipment or prescribes an additional allowance. List the actual gear first. Then mark which items the chart already accounts for and which must be counted separately. Check the sling assembly, lifting points, hardware, spreader or lifting device against their applicable ratings; a successful crane calculation cannot rate that gear.
For OSHA §1926.1417(k) and (o), equipment must stay within rated capacity and the operator must verify load weight using an allowed method. Use the documented weight of the payload, accessories and hardware. For any hoist rope allowance, follow the exact chart instructions, which may depend on reeving and how much rope is hanging at the position. Do not subtract the weight of the drum's entire rope inventory or deduct a hook block again if the rating already includes it. If a block or reeving is changed, check whether that changes the applicable chart, allowance, hoist limit or operating envelope.
Work the net and gross methods on matched terms
Façade example. In this hypothetical case, the equipment's instructions give a gross rating of 7,200 lb at the proposed placement and require separately accounting for the following equipment. These amounts and inclusion rules belong to the exercise.
| Item | Weight counted against the rating |
|---|---|
| Required hook block | 950 lb |
| Additional suspended rope allowance for the pick | 250 lb |
| Spreader, slings and hardware | 1,200 lb |
| Façade assembly | 4,500 lb |
| Total | 6,900 lb |
The equipment subtotal is 2,400 lb. The net capacity for the façade is 7,200 − 2,400 = 4,800 lb and the façade leaves 300 lb of margin. The gross calculation gives the same margin: 7,200 − 6,900 = 300 lb. Percentage of this gross rating used is 6,900 ÷ 7,200 × 100 = 95.83%. The ratio of 4,500 to 4,800 expresses the portion of the remaining payload capacity used after deductions; it answers a different question. If the approved site plan sets a lower utilization ceiling, use the same basis as that plan specifies and check it independently.
A farther point on the revised route gives a rating of 6,800 lb. With the same gear and counted allowance, the gross demand exceeds that rating by 100 lb. Moving that point inward or using a permitted configuration that can carry the demand might solve the chart problem. Any such change still calls for a new route, capacity and hoist check. In another configuration a manufacturer might publish a rating that already includes a specified hook block. In that case compare on the published basis and add only items the instructions require separately.
Verify the independent hoist limit
The chart and the hoist instructions may limit reeving, line pull and gear selection independently. Read the applicable capacities and use the authorized parts of line and compatible block. More parts of line cannot raise the structural rating at a radius. An estimate of ideal force divided by the number of supporting parts also cannot replace the hoist and reeving tables.
For tower cranes, OSHA §1926.1435(e)(5)(v)–(vi) separately addresses load moment and hoist line pull limiting devices, including each ratio on a multiple-speed hoist transmission. If either aid fails in service, §1926.1435(e)(3)–(5) governs the safe stop, any specified temporary measures, more protective manufacturer alternatives and the repair deadline. The temporary load moment measure calls for a radius indicator or measured radius, plus a reliably determined load weight supplied to the operator before the lift. The temporary line pull measure is to ensure the load stays within the hoist capacity, including each applicable gear ratio. Both are Category I aids. The repair deadline is seven calendar days, with the documented timely parts-order exception and a seven-calendar-day deadline upon receipt of the required parts. Check the repair status and applicable measures before the lift. A moment limiter and a line pull limiter may impose different boundaries on the same lift. Verify both before planning to operate at a radius, and follow the equipment procedure when either aid indicates a problem.
The gross rating is 7,200 lb. The chart requires deductions of 950 lb for the block, 250 lb for the rope allowance and 1,200 lb for the rigging. What payload capacity remains?
4,800 lb.
4,500 lb.
5,050 lb.
6,000 lb.
The 4,500 lb façade and the same 2,400 lb of counted gear reach a position with a 6,800 lb gross rating. What is the result?
The lift has 2,300 lb of spare capacity.
The lift is acceptable because the start point passed.
The lift still has 300 lb of spare capacity.
The demand exceeds the rating by 100 lb.
The tower chart explicitly includes the specified installed block. How should it be treated when determining remaining payload capacity?
Deduct the chart-included block once more along with all other gear.
Account for it as part of the rating's stated basis and subtract only the separately countable allowances.
Make no deductions of any kind if a load indicator is available.
Use the largest chart rating and base all allowances on that position.
Sections you finish are checked off in the contents.