12.3 Overlapping Slewing Radii, Zoning & Anti-Collision Systems
Key Takeaways
Under OSHA §1926.1424(b), the controlling entity institutes a coordination system when any part of one crane is within another crane’s working radius. If none exists, the employer or employers operating the equipment institute it.
Section 1926.1435(b)(6) requires a fixed-jib tower crane layout that prevents one crane from contacting another’s structure. Passing over is permitted if contact is prevented.
Check actual spatial clearances for crane structures, blocks, lines, rigging and loads. Verify the free-slew envelope separately from any powered operating restrictions.
Use the actual electronic system’s instructions and verify the configured limits. Maintain a reliable signaling and hold procedure for the shared work.
Identify where the cranes can interfere
OSHA §1926.1424(b) assigns the coordination system to the controlling entity when part of one crane is within the working radius of another. If there is no controlling entity, the employer or employers operating the cranes must institute the system. §1926.1435(b)(6) separately requires fixed-jib tower cranes to be located so that neither can contact the other’s structure. One crane may pass over another if the arrangement prevents structural contact. If two cranes will support one load, the separate plan and direction requirements in §1926.1432 also apply.
For equipment in its scope, ASME B30.3-2025 §3-1.2 requires a qualified person’s site plan before erection. Consider both neighboring crane envelopes and local hazards such as roads and power lines. On a plan view, a shared area identifies where to investigate. In elevation, consider the heights and travel of the jibs, counterjibs, towers, hook blocks, lines, rigging and the loads. The jib structures might clear while a hoist line still crosses the lower jib. Check loaded geometry, movement and clearance allowances from the actual equipment and plan.
| Conflict | Planning decision |
|---|---|
| Jib or counterjib near a neighboring structure | Verify the installed geometry and permissible movements. Changing jib heading leaves the tower in the same location. |
| Shared pickup or landing | Define who may enter, where the other crane holds, how clearance is confirmed and what happens if the zone cannot be released. |
| Crane parked in free slew | Verify the actual out-of-service envelope for both cranes, including the jib, counterjib and line. Check the applicable ASME §3-1.4(n) provisions and parking procedures in section 12.2. |
| Overhead power line | Apply the regulated work-zone and clearance decision to all relevant parts of the equipment and load. Check the separate warning and other protections below. |
Use zoning as part of the plan
The Potain Top Tracing 3 example supports configured prohibited areas, inter-crane management, hook-height management in prohibited areas and travel-track management. Use the equipment documents to verify the actual functions, configured data, required checks, limitations and actions when the system is unavailable. Update the plan and required setup when the crane position or elevation, jib geometry or modeled obstructions change. A limit on one motion can leave a different motion or the load itself exposed. Do not use an alarm reset, a display indication or an improvised override as permission to move through a conflict area. Operating controls must not be assumed to protect a crane in free slew.
For a line covered by §1926.1408, first assess the work zone with the 20 ft screen. If triggered, Option 1 calls for verified deenergization and visible grounding, Option 2 uses 20 ft and Option 3 uses Table A after determining voltage. For example, on a known 115 kV line the Table A distance is 15 ft. If the Option 3 assessment shows possible encroachment on that distance, apply §1926.1408(b). A configured range warning or limiter qualifies as one measure only when it meets the applicable provision. The required planning, warning and any additional safeguards still apply. At a shared delivery point, separately plan pedestrian and load-path controls under the conditions in §1926.1425.
Coordinate entry and stop decisions
Use the site sequence, agreed hold points and positive confirmation before releasing another crane into the shared area. For a blind landing, provide a qualified signalperson when the operator lacks full view of the point of operation. A camera is useful where its view and transmission are suitable. If signaling is required and the ability to transmit is interrupted, §1926.1419(f) requires safely stopping operations that require signals, with restart after transmission is restored and a proper signal is given and understood. A safety problem needing discussion with the signalperson also requires their agreement with the operator before restart under (g). Under (m), identify the intended crane before giving a function/direction, or use an equally effective identification method. If using electronic signaling, apply §1926.1420, including its shared dedicated channel option for coordination.
Worked decision. The lower crane’s fixed apex is at 215 ft where the proposed route would cross it. For this obstacle the approved site plan requires 7 ft of clearance, so the lowest suspended point would need to be at least 222 ft. At the highest permitted lift position, the surveyed reference at the top of the upper crane’s block is 240 ft. The stated 37 ft vertical drop from that reference already includes the block, rigging and the truss in its lift orientation. The lowest point would be 203 ft, so this direct crossing fails the plan by 19 ft. Turning the lower crane leaves the fixed apex in place. Replan the truss route away from the apex and verify the entire envelope and shared-zone holds before releasing the move.
With the stated 240 ft block reference, 37 ft vertical drop and 222 ft required load clearance elevation, how does the proposed route over the lower crane’s fixed apex compare?
It clears by 18 ft because only the block elevation matters.
It is 19 ft below the required elevation and needs a different verified route or configuration.
It clears if the lower crane rotates its jib away from the lift.
It is compliant whenever the upper crane has sufficient rated capacity.
What should the lift team confirm before relying on an electronic prohibited-area function for one crane’s working motion?
That all cranes use an identical automatic deceleration sequence.
That activation also clears the full out-of-service swing arc.
That the operator can always reverse out after an automatic stop.
The actual system’s functions, configured geometry, checks and response to a fault, alongside the site coordination procedures.
During work involving overlapping crane envelopes, a blind lift loses the required signal link. What is the first response, and when may operations requiring signals resume?
Safely stop those operations. Resume after the signal link is restored and a proper signal is given and understood.
Continue slowly under the existing shared-zone reservation.
Lower the load until the link is restored, then obtain a new signal.
Resume once the anti-collision display locates both cranes, even without the signalperson.
Sections you finish are checked off in the contents.
You've completed this section
Continue exploring other exams