9.2 Reading Mobile Crane Load Charts & Rating Boundaries

Key Takeaways

  • Select the model, boom or jib arrangement, counterweight, support, operating sector and mode before reading the chart.

  • Use the applicable operating radius and chart notes. Check loading throughout the planned path, including where ratings or operating regions change.

  • The chart controls how to handle unlisted values and interpret symbols. Asterisks can have different meanings on different charts.

  • To find a permissible range, use the entire approved range and chart values for the same demand and configuration, including minimum geometry limits.

Last updated: November 2026

Read the chart from the configuration outward

Verify the actual crane and chart before locating a number. Check counterweight, boom length and configuration, main boom versus jib or auxiliary point, operating sector, support and other limits. §1926.1417 requires applicable manufacturer procedures and prohibits exceeding rated capacity. Confirm what the chart includes and what must be separately counted. Review reeving and hardware ratings as separate checks.

On the CCO mobile practice supplement, the Grove chart defines operating radius horizontally from the axis of rotation projected to the support surface to the center of the vertical hoist line or tackle under load. The boom point can deflect when the crane takes load. Use the chart’s radius definition and plan for the geometry at each loaded phase. Where numbers in parentheses show loaded boom angles, treat them as angle references according to the specified chart. A range diagram may help check reach, but a geometric point on a diagram does not establish a rating.

Chart entry or noteHow to apply it
Support or working sectorUse the one valid at that phase. A rating may change during swing even if the radius does not change.
Blank or excluded positionCheck the chart’s restriction. Do not assign capacity using neighboring rows.
Bold line, asterisk or other symbolRead the legend for this chart to determine its significance.
Geometry between listed valuesUse the instruction that applies to that chart. Treat length, radius and boom angle as separate inputs.

The Grove practice chart marks its structural range above a bold line. Its asterisk marks a capacity based on maximum boom angle. The Manitowoc 888 Series 2 practice chart uses asterisks to denote ratings based on structural competence. Structural and stability limits govern ratings in different parts of the charts. A machine can be overloaded without a visible change in its support. Do not use tipping or visible flex as a test of capacity. The Grove notes describe a stability basis not exceeding 85% of tipping load for the fully extended outrigger setup; the 888 Series 2 practice chart uses a basis not exceeding 75% of static tipping load. These describe the cited chart configurations and cannot be reapplied as payload allowances.

Work a between-row decision

Use the rough-terrain fully extended outrigger, 360° chart in the CCO supplement, printed page 6. For the 70 ft main boom, the chart lists 18,050 lb at 35 ft and 14,650 lb at 40 ft. A planned 37 ft loaded radius is between those rows. The Operation note on printed page 1 directs use of the smaller applicable capacity at the next larger radius or from the neighboring boom lengths when the length is between entries. Because the 70 ft length is listed exactly here, use the 40 ft row: 14,650 lb gross. With a 15,000 lb gross demand, the lift fails at that point by 350 lb. Interpolating between the listed rows would change the decision contrary to the chart notes.

Find the applicable radius interval

When given a load and configuration, identify the permitted radius range first. Check the chart and equipment instructions for the minimum rated radius, maximum permitted boom angle and any other reach restrictions. Then compare demand against the entries for the same setup to find the longest warranted working radius. If a specific load or path also requires a minimum clearance radius, the usable interval is where the capacity and geometry constraints overlap. Do not carry a radius from an incompatible setup.

For example, using the same 70 ft practice configuration and a 14,500 lb gross demand, the 40 ft entry passes by 150 lb, while the 45 ft entry (11,800 lb) fails. Under the provided between-entry instruction, a planned radius just over 40 ft would use the next larger entry. This establishes the longer capacity boundary for this comparison. The chart’s smaller-radius geometry restrictions and the planned route still apply. For instance, if the plan also needs at least 34 ft of radius to clear a barrier, use 34 to 40 ft as the initial planning interval for this exercise. Check every phase in that interval, including near the barrier and at the final set, with the actual loaded geometry and tolerances.

Test Your Knowledge

What does an asterisk mean in the CCO Manitowoc 888 Series 2 study chart’s capacity table?

A

Unlimited duration at that load.

B

A rating adjusted to the payload after all deductions.

C

The same meaning as every mobile crane chart’s asterisk.

D

The marked rating is based on structural competence.

Test Your Knowledge

What is a safe interpretation when a rating is limited by structural strength?

A

Use the rated limit and all applicable conditions. The crane can be structurally overloaded without a visible sign of tipping.

B

Increase load until a rear pad starts to lift.

C

Add a percentage of the chart’s unused stability as structural reserve.

D

Treat a loaded-radius check as optional when a strong boom is installed.

Test Your Knowledge

A CCO practice chart lists 18,050 lb at 35 ft and 14,650 lb at 40 ft for the selected boom length and setup. The chart directs next-larger-radius selection for an unlisted radius. Which value governs at 37 ft?

A

18,050 lb

B

14,650 lb

C

16,690 lb

D

17,300 lb

Sections you finish are checked off in the contents.