1.3 Matting, Cribbing & Outrigger Pad Sizing
Key Takeaways
Use the support reactions for the actual crane configuration and lift path, including the governing position of the load and counterweight.
Average bearing pressure is support force divided by effective contact area. Compare it with the site’s allowable bearing pressure using consistent units.
One square foot contains 144 square inches, so multiply psi by 144 to convert to psf.
Check the mat’s rating and stiffness, the float contact, the support arrangement and the underlying ground. The mat’s nominal area can exceed its effective bearing area.
For assembly and disassembly, OSHA 1926.1404(q)(5) specifies where outrigger or stabilizer blocking goes and requires compliance with its stability and support provisions.
1.3 Matting, Cribbing & Outrigger Pad Sizing
An outrigger float transfers vertical reaction from the crane to its support. Adding a suitable mat spreads that force over a larger effective area. The lift director needs two independent inputs to determine whether the arrangement is suitable: the reaction under the planned crane configuration and the bearing conditions at the actual support point.
Determine the governing outrigger reaction
Load on each support changes as the boom and counterweight move. The most heavily loaded support may change between setup, picking, swinging and landing. The crane's own configured weight includes components such as installed counterweights. Account for the suspended load and lifting gear consistently with the method used to obtain reactions, so their weights are included once.
Use crane-specific reaction data or an appropriate lift planning analysis for the configured equipment and full lift path. Manitowoc’s outrigger pad load tools are examples for their applicable products. Enter the actual machine configuration and use the most demanding reaction for the support under review. Dividing the combined weight into four equal shares would miss the influence of radius, slewing sector and counterweight. The ratio carried by any one support is a result of the configuration and load path.
Calculate average bearing pressure
For a first check under an effective mat contact area, divide vertical reaction by area to find the average pressure :
Use pounds-force with square feet for pounds per square foot (psf), or pounds-force with square inches for pounds per square inch (psi). One square foot contains 144 square inches, so multiply psi by 144 for psf and divide psf by 144 for psi. For example, 20 psi is 2,880 psf. In the other direction, 3,600 psf is 25 psi.
If the site supplies an allowable bearing pressure , an initial minimum effective area for the assumed average-pressure check is:
The result assumes the stated area is effective in transferring the reaction into the ground. It also assumes the force used captures the demand at the ground. Account for support weight and other loads if they matter to the comparison. The pressure beneath a real mat need not be uniform. Apparent contact area can be lost across a low spot or if the mat deflects under a concentrated load.
Select and check the support
| Material | What to check when it is proposed |
|---|---|
| Timber mats | Timber condition, member and connection capacities, contact orientation, local crushing and bending under the float. |
| Engineered polymer or composite pads | The manufacturer’s permissible load, required contact, deflection and placement criteria. |
| Fabricated steel mats | Design capacity under the planned load and placement, appropriate handling, and adequate bearing at the intended support points. |
Check the whole stack and load path, from the float through mat or cribbing to verified ground. Mat area alone does not establish the strength of the system. A larger pad may still span an unsupported area, bend, shift or settle. Check the float placement and contact against the support design. Use manufacturer limits for material and placement, and get an appropriate support design when the surface, height, reactions or geometry require one.
OSHA 1926.1402(b) requires ground and any needed supporting materials to meet the manufacturer's support and leveling specifications. During assembly or disassembly, 1926.1404(q)(5) requires blocking that meets (h)(2) and (h)(3) for size, amount, condition, stacking and placement with regard to stability and support. Place it under the outrigger or stabilizer jack float or pad, or under the outer bearing surface of the extended beam on designs without a jack. Verify the operating instructions for the actual machine. For example, the Grove RT9130E-2 operator manual instructs operators to use adequate cribbing under floats to spread the load and to check for settlement frequently.
Worked calculation: screen the mat for a 120,000 lb reaction
A telescopic crane will place a chiller. The lift plan supplies a governing reaction of 120,000 lb at one outrigger. The site assessment allows 3,000 psf at that support, about 20.83 psi. For this arithmetic exercise, ignore the mat’s own weight. Compare a 24-inch round float and a 6 ft by 8 ft mat.
- Float alone. A 2 ft diameter gives a radius of 1 ft and an ideal contact area of square feet. The average would be psf, or about 265.3 psi. This is above the site limit.
- Initial area check. square feet of effective contact. A square with a 40 square foot area has sides of about 6.32 ft.
- Candidate mat. The 6 ft by 8 ft mat's nominal area is 48 square feet. If all of it is effective, the average pressure is psf, or about 17.36 psi. This passes the first arithmetic check.
- Check the consequence of partial support. If only 36 square feet carries the reaction, the average becomes about 3,333 psf. That exceeds the site limit and the current setup must be revised. Confirm effective contact, support distribution and mat strength before using the configuration. Recheck when site conditions change.
The exam can ask for a calculated area or pressure using simplified inputs. In a lift plan, record the reaction source, allowed bearing pressure, effective support geometry and verification of the chosen mat.
A geotechnical report states that the soil on site has an allowable bearing capacity of 30 psi. What is the equivalent bearing capacity expressed in pounds per square foot (psf)?
3,000 psf
4,320 psf
1,440 psf
2,160 psf
During crane assembly a jack-equipped outrigger requires blocking. Where does OSHA 29 CFR 1926.1404(q)(5) require it to be placed?
Under any convenient part of the carrier frame
Under the outrigger beam beside the jack
Under the centerline of the nearest wheel axle
Under the outrigger jack’s float or pad
A mobile crane has a calculated maximum outrigger reaction of 80,000 lb and a site allowable bearing pressure of 2,000 psf. What minimum effective contact area does the simple average-pressure check require, ignoring mat weight?
20 square feet
32 square feet
40 square feet
50 square feet
Sections you finish are checked off in the contents.