3.4 Reasonable Skill and Care and Fitness for Purpose

Key Takeaways

  • Section 15(1)(o) of Act 138 addresses a registered person’s failure to discharge duties with due skill, care and diligence.

  • A reasonable-skill-and-care term tests professional conduct. An express fitness-for-purpose warranty can separately require the stated performance under the agreed conditions.

  • Identify the parties, particular purpose, performance criteria, testing conditions and scope of the guarantee before concluding whether it was breached.

  • Section 16(1)(a) of the Sale of Goods Act 1957 applies subject to its own conditions and proviso. The contract and policy each need to be read to assess an insured claim.

Last updated: November 2026

Start with the scope and the exact words

A consulting engineer appointed to design a pumping station may undertake to exercise reasonable skill and care in the design. A design-and-build contractor on the same project may give an express fitness-for-purpose warranty for a defined output. Identify the claimant, defendant and legal basis before using either standard. The contractor's promise to the employer does not by itself tell you what the consultant promised the contractor.

A skill-and-care duty concerns the way an engineer performs the services. Ask which facts were reasonably available, which checks a competent practitioner would make in that role and what the engineer actually did. Test the assumption using contemporary evidence. For example, an omission of a known downstream operating restriction is relevant to breach. You still need to test whether it caused the claimed loss. Section 15(1)(o) of the Registration of Engineers Act 1967 separately makes failure to discharge professional duties with due skill, care and diligence a disciplinary ground. A discipline question and a claim for compensation have different legal tests.

A performance obligation concerns the result described by the agreement. The International Federation of Consulting Engineers (FIDIC) distinguishes promises to deliver a result from obligations to use reasonable skill and care. A client relying on an unqualified performance warranty may establish breach without showing careless design. Read the warranty’s conditions and exclusions, the risk allocation and evidence of actual performance. If the contract promises an output only within a specified operating envelope, performance outside that envelope does not itself establish breach of that promise.

QuestionSkill and careAgreed performance
What is assessed?Conduct in the defined task and circumstancesResult within the defined operating or test conditions
Which evidence is useful?Assumptions, checked calculations, decisions and site recordsAcceptance test results, input conditions and the wording of the promise
Which risk needs checking?Scope of work, applicable standard and causationDefined performance threshold, exceptions and which party undertook it
Who made the commitment?The professional or firm under its own appointment or dutyThe party who accepted the particular obligation

Worked example. A stated pump output

A contractor agrees to provide two duty pumps that together deliver at least 120 litres per second at a stated test head and inlet condition. Its design consultant has undertaken reasonable skill and care and has given no separate output warranty. A controlled test records 114 litres per second at the specified conditions, a shortfall of 6 litres per second, or 5% of the stated minimum. On the assumed terms, the test is evidence that the contractor missed its agreed output. The employer does not need a negligent calculation to show that shortfall. Under the consultant's separate appointment, examine the pump selection, design assumptions, contractor substitutions and test setup. A performance gap can motivate that review. Whether the consultant breached a skill-and-care obligation depends on what the consultant undertook and did.

Run the example again with a field measurement taken at a head outside the agreed test range. The recorded rate alone is then insufficient to determine the contractual result. The parties need data from the defined conditions or the agreed procedure for evaluating deviations. This is why an essay should connect the measurement to the specific promise.

Goods supplied for a stated purpose

For a sale within the Sale of Goods Act 1957 in the States of Peninsular Malaysia, section 16(1)(a) may imply a condition of reasonable fitness. The buyer makes the purpose known in circumstances showing reliance on the seller's skill or judgment, and the goods are of a description the seller supplies in the course of business. Check the proviso for a specified article sold under its patent or trade name. For example, an operator asks a seller to select an unbranded pump for a disclosed duty and relies on that selection. Analyse the sale conditions separately from any promise by the consulting engineer.

Check the professional indemnity policy

Professional indemnity insurance (PII) coverage depends on the policy's insuring clause, exclusions, endorsements and claim circumstances. A contract warranty may extend liability beyond the work and liabilities described in a particular policy. If the policy in a question excludes liabilities assumed solely under a contract beyond what would otherwise attach, compare the pleading and the policy definition. Identify any independently alleged negligence before treating the exclusion as decisive. An employer's obligation, a designer's duty and an insurer's cover each come from their own instrument.

Act 138, section 15(1)(o) · FIDIC briefing on fitness for purpose · Sale of Goods Act, sections 1 and 16 · Federal Court, scope of undertaking in Lok Kok Beng

Test Your Knowledge

The executed contractor agreement requires a minimum output of 120 L/s at the specified test conditions. A valid test shows 114 L/s. Which fact directly establishes the performance shortfall for the stated obligation?

A

The consultant’s calculation records have no missing pages

B

The contractor used the product originally named by the consultant

C

The tested output is 6 L/s below the agreed minimum under the specified conditions

D

The contractor had a separate policy covering negligence

Test Your Knowledge

A policy in a scenario expressly excludes liability assumed solely under a contract if the insured would have no such liability without the added promise. The only pleaded breach is of an additional output warranty. What should the consultant check?

A

Whether the express exclusion applies to the warranty-only claim, including any endorsements

B

Whether the warranty automatically amends the insurer’s contract

C

Whether the contractor’s technical expertise makes the exclusion ineffective

D

Whether buying a policy proves the asset met the performance test

Test Your Knowledge
Multi-Select

Which three facts support an implied fitness condition under section 16(1)(a) on a sale within the Sale of Goods Act 1957, assuming the patent or trade-name proviso does not apply?

Select all that apply

The seller is asked to select a pump for a disclosed operating duty

The purchaser relies on the seller’s judgment in choosing suitable goods

The consultant has already paid the seller’s whole invoice

The seller supplies goods of that description in the ordinary course of business

Sections you finish are checked off in the contents.