5.7 Water and Sewerage Regulation and Stage Certification
Key Takeaways
Act 654 establishes SPAN. Act 655 sets the industry framework in Peninsular Malaysia and the Federal Territories of Putrajaya and Labuan.
Section 50 permits cover specified work and services, subject to applicable exemptions. Section 174 provides for certifying agencies and their stated functions.
Identify the applicable Selangor G-series forms by work package. External water, sewerage reticulation and sewage treatment plants have distinct documentation.
Separate the institutions and approvals
The National Water Services Commission Act 2006 (Act 654) establishes the regulator SPAN, or Suruhanjaya Perkhidmatan Air Negara. The Water Services Industry Act 2006 (Act 655) provides the industry framework, including licensing, approvals and requirements for certain work. Section 1(2) specifies Peninsular Malaysia and the Federal Territories of Putrajaya and Labuan. A water service licensee provides the relevant utility service. It has a different role from SPAN and from a certifying agency.
Under section 50, specified construction, connection, modification, repairs, maintenance or sewerage services require a written permit from the Commission, subject to applicable exemptions. Define the work before checking the permit. Preparing engineering designs and performing the permit-controlled work are separate tasks. A Professional Engineer with Practising Certificate submitting drawings still needs to establish their authority under the professional and technical requirements for that package.
For work within section 45, first obtain written approval of the plans or specifications that require Commission approval. The rule can apply to an alteration or disconnection as well as new construction. A permit for the person carrying out the work does not approve the plans. Conversely, the approved plans do not establish that the person carrying out the work holds the required permit.
Section 174 provides for certifying agencies. Its functions include approving plans or detailed designs within the stated scope and certifying compliance with technical standards. Indah Water Konsortium (IWK) describes its appointment as Certifying Agency for Sewerage Works Approvals under that section for West Malaysia and Labuan. Check the project's actual route, such as sewerage works approval followed by completion documentation for the applicable facility. Confirm the water connection with the appropriate water utility and current approval route. A single project file can therefore contain separate approvals and inspection records for water and sewerage.
Use the correct Selangor stage record
| Applicable form | Work package to check |
|---|---|
| G5 and G6 | Internal cold water plumbing and internal sanitary plumbing, respectively. Match the installed work to the approved plans and the relevant statutory signatories. |
| G13 | External water supply. The BEM form guide calls for the applicable water authority confirmation that supply is ready for connection. |
| G14 | Sewerage reticulation. The BEM guidance identifies the applicable sewerage approval reference. Verify the current approval and completion documents prescribed for the actual works. |
| G15 | Sewage treatment plant where applicable. The BEM guide identifies the relevant clearance letter for this scope. |
The applicable stage form reflects the jurisdiction and plan approval. Check the actual form and project scope, including its provision for an inapplicable stage. The Principal Submitting Person (PSP) checks the required completion evidence before Form F is issued.
Worked example: an apartment site adding a sewer connection
A Selangor development has a water main and a separately reviewed connection to the public sewer, with no new on-site sewage treatment plant. Its external water supply documents and connection-readiness confirmation relate to G13. For its sewerage scope, confirm which stage and documents the approval actually requires. A G15 clearance for a new treatment plant does not arise merely because a sewer connection exists. If an applicable clearance is still missing, identify the agency, what it has approved and what work remains before the relevant certification can be made.
Check a design revision against the original approval conditions. If the water pipe route changes while the sewerage design stays the same, confirm the treatment of the change with the applicable water approval body and retain the sewerage approval with its own revision reference. When the client asks whether written approval permits a discharge, consider the pollution and prohibited discharge provisions separately. The 2025 changes to Act 655, effective from 1 March 2025, include additional misconduct involving impairment or disruption of water and sewerage services. A proposal involving a trade discharge calls for the current statutory and technical requirements for that discharge.
For Sabah, consult the Sabah Water Supply Enactment 2003 for water and the Sewerage Services Enactment 2017 for sewerage. For Sarawak, check the Water Ordinance 1994 (Cap. 13) and the Sewerage Systems and Services Ordinance 2005 (Cap. 63), including the latter's urban-area application. Confirm the current operator and project forms locally.
Government description of Acts 654 and 655 · Act 655, sections 1, 50 and 174 · IWK certifying agency · BEM stage form guide · Sabah enactments register · Sarawak ordinance register · Sarawak sewerage ordinance · Parliamentary report on the 2025 Act 655 changes
Which statement correctly routes a project in Labuan and a separate one in Sabah?
Act 655 applies to both because both are on or near Borneo
Act 655 applies to Sabah and excludes Labuan
Act 655 specifies Peninsular Malaysia and the Federal Territories of Putrajaya and Labuan. Sabah’s equivalent water and sewerage matters have state regimes
Act 654 is the Sabah Water Supply Enactment
Match the applicable stage form to its work package in the Selangor example.
Match each item on the left with the correct item on the right
G5
G6
G13
G14
G15
Sections you finish are checked off in the contents.