2.1 Registration Tiers, Submission Rights & Titles (REA 1967)

Key Takeaways

  • The Registration of Engineers Act 1967 (Revised 2015) [Act 138] establishes six distinct registration classes administered by the Board of Engineers Malaysia (BEM): Graduate Engineer, Engineering Technologist, Inspector of Works, Professional Engineer, Professional Engineer with Practising Certificate (PEPC), and Accredited Checker

  • Regulation 22 ordinarily requires at least three years of experience for the Graduate Engineer route to Professional Engineer registration. At least one year of the training is in Malaysia under the prescribed supervision, subject to BEM’s powers under regulation 22(2).

  • Protected titles 'Ir.' (prefix) and 'P.Eng.' (suffix) under Section 7 are reserved strictly for registered Professional Engineers and PEPCs; misuse by unregistered persons, Graduate Engineers, or Engineering Technologists is a statutory offence

  • Section 8 provides ordinary submission rights for a PEPC residing and practising in Malaysia or an Engineering Consultancy Practice providing services in Malaysia, subject to restrictions and registered branch. Section 8A provides a separate limited PE route for qualifying equipment, plant or specialised-product plans or drawings.

  • Offences under section 24, including a contravention of section 24A(1), carry a maximum fine of RM50,000, imprisonment for up to three years, or both upon conviction.

Last updated: November 2026

Registration Tiers, Submission Rights & Titles (REA 1967)

In Malaysia, the engineering profession is regulated by statute under the Registration of Engineers Act 1967 (Revised 2015) [Act 138] (commonly referred to as REA 1967) and its subsidiary legislation, the Registration of Engineers Regulations 1990. Act 138 regulates engineering registration and professional engineering practice. It assigns BEM functions that include maintaining the Register and regulating conduct. The statutory regulator charged with maintaining the Register and enforcing Act 138 is the Board of Engineers Malaysia (BEM).

Use the registration category, the entry in the Register and the work involved to determine which activity the person may perform. Academic qualifications and practical experience help establish eligibility for registration.

The Six Registration Classes Under REA 1967

Following the landmark 2015 amendments to Act 138, BEM maintains six statutory classes of registered persons, each with clearly delineated qualifications, roles, and boundaries.

1. Graduate Engineer — Section 10(1)

A Graduate Engineer qualifies through an engineering qualification BEM recognises under section 10(1). A recognised accredited engineering degree is a common route. Section 7(2)(a) permits registered Graduate Engineers to take employment performing professional engineering services subject to section 8. Regulation 22 prescribes supervision for the training towards Professional Engineer registration. Graduate Engineers have no independent design sign-off or statutory submission rights and cannot use the titles Ir. or P.Eng..

2. Engineering Technologist — Section 10C

An Engineering Technologist holds a qualification BEM recognises under section 10C. BEM lists accredited engineering technology degrees among its routes. Section 7(2)(aa) permits registered Engineering Technologists to take employment performing professional engineering services subject to section 8. Like Graduate Engineers, Engineering Technologists hold no statutory plan submission authority and may not use Ir. or P.Eng..

3. Inspector of Works (IOW) — Section 10E

An Inspector of Works (IOW) holds a qualification BEM recognises under section 10E. Section 7(2)(ab) provides for employment to assist the Professional Engineer in supervising engineering work, subject to section 8. In practice the inspector can report measured workmanship, observed conditions and site records to the responsible engineer. An IOW cannot produce independent engineering designs or submit statutory drawings.

4. Professional Engineer (PE) — Section 10(2) & Regulation 22

For the Graduate Engineer route under section 10(2)(a), the applicant must be a registered Graduate Engineer and satisfy the practical experience requirements under Regulation 22. Normally, Regulation 22 prescribes at least 3 years of practical experience, structured into two distinct phases:

  • 2 years of general training that develops practical engineering judgment, design application, and site exposure; and
  • 1 year of professional career development and training across managerial and technical work. At least one year of the training must be in Malaysia under a PE in the same branch, with BEM able to approve supervision in a related branch or vary the Malaysian experience or supervision requirement under regulation 22.

In addition, the candidate must meet the assessment or membership route and other Board requirements. Section 10(2)(a) lists BEM’s Professional Assessment Examination (PAE), a professional qualification BEM considers equivalent, or Corporate Membership of the Institution of Engineers, Malaysia (IEM). A registered PE acquires the right to use the protected titles Ir. and P.Eng., and may practise within an organisation or under narrow statutory limits, but does not hold general statutory submission rights.

5. Professional Engineer with Practising Certificate (PEPC) — Section 10D

Introduced through the 2015 overhaul of Act 138, the Professional Engineer with Practising Certificate (PEPC) under Section 10D represents the practising tier of the profession. To qualify as a PEPC, an applicant must:

  1. Be a registered Professional Engineer under Section 10(2);
  2. Pass the Professional Competency Examination (PCE) administered by BEM (comprising Part A Common Paper and Part B Discipline Paper); and
  3. Satisfy the Board’s requirements. Section 10(4) requires residence in Malaysia at the time of application or renewal and for at least six months beforehand.

For a Submitting Person (SP) or Principal Submitting Person (PSP) role, read section 8 alongside the applicable building law and authority requirements. PEPC registration, the relevant engineering branch, and eligibility for that specific submission or certification are separate checks.

6. Accredited Checker (AC) — Section 10B

An Accredited Checker (AC) under Section 10B must be a PEPC in the relevant BEM-approved branch, have at least ten years of relevant building design and construction experience, and satisfy the Board of their competence. BEM provides application guidance for geotechnical and structural checking. The applicable building law and project dictate when independent checking is required.

Comparison of All Six Registration Classes

ClassStatutory SectionAcademic / Entry BasisPost-Qualification & Exam RequirementProtected Title (Ir. / P.Eng.)Statutory Submission Rights
Graduate Engineers.10(1)BEM-recognised engineering qualificationEntry registrationNoNo ordinary section 8 submission right
Engineering Technologists.10CBEM-recognised qualificationEntry registrationNoNone (works in applied engineering technology)
Inspector of Works (IOW)s.10EBEM-recognised qualificationSee BEM criteria for the applicable application routeNoNone (site supervision under PE/PEPC)
Professional Engineer (PE)s.10(2)Registered Graduate EngineerRegulation 22 experience plus a section 10(2)(a) assessment, qualification or membership routeYes (Ir. before name; P.Eng. after name)Narrow Section 8A exception only (proprietary equipment/plant)
PE with Practising Certificate (PEPC)s.10DRegistered PEPass PCE (Part A & Part B) + Board prerequisitesYes (Ir. before name; P.Eng. after name)Ordinary section 8 submission authority within registered branch and subject to applicable restrictions
Accredited Checker (AC)s.10BRegistered PEPC in relevant Board-approved branchAt least ten years’ relevant building design and construction experience and Board approvalYes, through PE registrationPerforms checking duties prescribed for the applicable work

Restrictions on Unregistered Persons & Protected Titles (Section 7)

Section 7 of REA 1967 strictly prohibits any unregistered person from:

  • Practising, carrying on business, or taking up employment that requires the performance of professional engineering services;
  • Holding themselves out as a registered Engineer, Engineering Technologist, Inspector of Works, or Engineering Consultancy Practice; or
  • Using the protected designations "Ir." (placed before the name) or "P.Eng." (placed after the name), or any title, abbreviation, or description likely to create the impression that the person is registered under Act 138.

A frequent exam trap involves Graduate Engineers or foreign engineers working in Malaysia on major infrastructure projects: even if an engineer holds a PhD or a Chartered Engineer credential from overseas, using Ir. or signing off local engineering drawings in Malaysia without active BEM registration violates Section 7.

Submission routes under sections 8 and 8A

Section 8 — ordinary submission authority

Section 8 ordinarily permits submissions by a PEPC residing and practising in Malaysia or a registered Engineering Consultancy Practice (ECP) providing professional engineering services in Malaysia. Both routes are subject to branch, Board restrictions and other applicable law. For an electrical component of a mixed-discipline submission, confirm the registered electrical engineer responsible for that design.

Section 8A — Narrow PE Submission Exception

Section 8A carves out a tightly bounded exception for a registered Professional Engineer (without a Practising Certificate). A PE may submit plans or drawings to a person or authority in Malaysia only if those plans or drawings relate to an equipment, a plant, or a specialised product invented or sold by that PE or by that PE's employer — and Section 8A expressly excludes a client.

Important

Section 8A Boundary Rule: The Section 8A exception covers vendor-engineered machinery, process skids, or proprietary equipment sold by the PE's employer. Apply the exception to plans or drawings relating to the qualifying product. Verify the boundary between the product submission and separate client project plans, such as building services and civil foundations.

Practical Malaysian Scenario

Consider Ir. Lim, a registered Mechanical PE (without a Practising Certificate) employed by a Selangor manufacturer of specialised industrial chiller plants. When the manufacturer sells its proprietary chiller unit to a semiconductor plant in Kulim Hi-Tech Park, Ir. Lim has a section 8A basis to submit the manufacturer’s drawing of that unit, subject to any separate authority and equipment approval rules. The client then asks him to submit a stand-alone factory distribution system he designed for the project. The sale of the chiller does not create a section 8A basis for that separate client design. Identify the qualified submitting practitioner under section 8 and the applicable authority rules.

Statutory Offences & Penalties (Sections 24, 24A & 25)

To give teeth to its registration framework, Act 138 criminalises unlawful practice, misrepresentation, and improper employment:

  • Section 24 (False Registration & Unlawful Practice): Any person, sole proprietorship, partnership, or body corporate who procures or attempts to procure registration or a certificate by knowingly making false or fraudulent declarations, forges registration documents, or contravenes Section 7/8 commits an offence. Upon conviction, the offender faces a fine not exceeding RM50,000, imprisonment for a term not exceeding 3 years, or both.
  • Section 24A (Restriction on Employment): Section 24A(1) restricts employing a person or business other than a PEPC or ECP to perform professional engineering services. Section 24A(2) preserves authorised activities under a certificate covered by section 7(3). Read the employment and individual registration provisions together for the work described. Section 24(h) covers a contravention of section 24A(1).
  • Section 25 (General Penalty): Supplies the general penalty where no penalty is expressly provided. Section 25(1) sets a maximum of RM10,000, imprisonment for up to one year, or both upon conviction.

Act 138, sections 7–8A, 10–10E and 24–25 · Registration of Engineers Regulations, regulation 22 · BEM registration requirements

Test Your Knowledge

Ir. Farah is a registered Mechanical Professional Engineer (PE) without a practising certificate, employed by a pump manufacturer. For which drawing does section 8A of the Registration of Engineers Act 1967 provide a submission route, assuming any separate authority requirements are met?

A

Mechanical layout drawings specifically for a specialised industrial pumping skid invented and sold by her employer

B

Complete building plumbing and sanitary reticulation plans prepared for a commercial developer client

C

Structural concrete plinth and foundation drawings supporting the pump house for the buyer's civil contractor

D

Independent third-party structural safety certification for a high-rise plant room

Test Your Knowledge
Multi-Select

Which THREE statements accurately reflect the registration tiers and protected title rules under the Registration of Engineers Act 1967? (Select three)

Select all that apply

Under Regulation 22, a Graduate Engineer normally needs 3 years of practical experience (2 years general plus 1 year professional) to apply for Professional Engineer registration

An Engineering Technologist registered under Section 10C is permitted to use the suffix 'P.Eng.' after passing two years of industrial training

Section 10B requires an Accredited Checker to be a PEPC in the relevant BEM-approved branch with at least ten years of relevant practical experience in building design and construction

A Professional Engineer with Practising Certificate (PEPC) must pass the PCE and may only submit plans within their registered engineering branch

An Inspector of Works registered under Section 10E may independently endorse and submit minor drainage drawings to local authorities

Test Your Knowledge

A project director knowingly employs an unregistered foreign degree holder to sign and submit civil engineering calculations for a factory extension in Johor. What is the maximum criminal penalty upon conviction under Section 24 (read with Section 24A) of the Registration of Engineers Act 1967?

A

A written reprimand from BEM and a fine not exceeding RM10,000

B

A fine not exceeding RM25,000 or imprisonment up to 1 year, or both

C

Suspension of the company's SSM registration without any monetary fine

D

A fine not exceeding RM50,000, imprisonment for a term not exceeding 3 years, or both

Sections you finish are checked off in the contents.