2.4 Circadian and Non-Visual Effects of Light
Key Takeaways
Melanopsin-containing retinal ganglion cells receive light signals, including input from rods and cones. CIE S 026 provides separate spectral weightings for five photoreceptor types.
Melanopic equivalent daylight illuminance is expressed in lux. It is photopic illuminance multiplied by the melanopic daylight efficacy ratio for the spectrum at the same point and plane.
Evaluate light in the direction it reaches the eye. A horizontal desk reading cannot establish a vertical eye-level target.
Time of exposure, duration, spectrum and light history matter. An exposure metric is not a prediction of a particular person’s biological outcome.
Treat a project’s visual and non-visual acceptance criteria separately. Verify tasks, glare, safety and resulting exposure under the actual control settings.
Image-forming and non-image-forming responses
A lighting design can affect what people see and when they are exposed to light. Intrinsically photosensitive retinal ganglion cells (ipRGCs) contain melanopsin and also receive input from rods and cones. Pathways relaying these signals influence the internal clock and the pupil response. The CIE S 026 metrology standard provides spectral sensitivities for the five photoreceptor types: the three cone types, rods, and the melanopsin-based response. The tabulated melanopic weighting peaks near 490 nm. That is a peak of a weighting curve, not an instruction to use only that wavelength.
Photopic illuminance uses a different weighting for vision. Two sources with the same photopic illuminance can deliver different melanopic exposures. Likewise, two products with the same correlated color temperature (CCT) can have different spectra and different melanopic response estimates. Use measured spectral data rather than a color-temperature label to compare them.
Quantify light at the observer
Melanopic equivalent daylight illuminance (melanopic EDI) is the illuminance of CIE standard daylight illuminant D65 that would produce the same melanopic irradiance as the light being evaluated. It is reported in lux. For a spectrum at the observer:
Here is photopic illuminance and melanopic DER is the dimensionless melanopic daylight efficacy ratio. Use the illuminance and DER of the same light at the same measurement plane. For D65, the ratio is 1 by definition. Do not substitute a legacy equivalent melanopic lux number or a model that predicts a biological effect directly; definitions and reference spectra can differ.
Usually, an upright seated or standing observer is evaluated on a vertical plane at representative eye height facing the view direction specified for the project. For a person lying down or looking at a tilted work surface, use the measurement geometry relevant to the actual gaze and project criterion. If several sources run at once, evaluate the combined spectrum or add their individual contributions at the same point and plane.
Worked example: Calculate, then check the design
A brief for an office specifies a project daytime target of melanopic EDI at the seated eye. Both candidate scenes produce vertical photopic illuminance there.
| Scene | Melanopic DER at the eye | Melanopic EDI |
|---|---|---|
| A | 0.45 | |
| B | 0.85 |
Only Scene B meets the stated target. Equal vertical photopic illuminance does not establish equal desk light, glare, input power, or color rendering. Check those independently before accepting a scene. In a separate mixed-light reading, of electric light at DER 0.60 and of daylight at DER 1.00 contribute melanopic EDI in total. Do not average the two DERs without weighting them by their contributions.
Time and applications
Light can affect circadian timing differently depending on when it is received. Timing, duration, spectrum and prior exposure affect interpretation. The CIE 2024 position statement discusses recommendations informed by healthy-adult studies: at least 250 lx melanopic EDI at the eye by day, at most 10 lx for the three hours before bedtime, and at most 1 lx while sleeping. These are not general building-code requirements or treatment targets for individual patients. The position statement discusses different considerations where people need enough light for nighttime activity.
| Application | Practical verification |
|---|---|
| Daylit office | Record a typical seated view and check a representative shade position and electric scene. Show whether the exposure target is met when shades close, not only under a bright clear sky. |
| Patient room | Check the planned eye position, including a bedbound view if relevant; the view can differ from a seated office. Keep staff task visibility, patient controls and applicable safety requirements separate from any exposure goal. Do not promise a clinical outcome from a lighting metric. |
| Senior living | Check whether controls are understandable, the path remains safe, and daytime common areas provide useful light without uncomfortable glare. User needs can differ within the same occupancy. |
| Tunable system | Name the verified scenes in the commissioning script. Check intensity and spectral output after the scheduled transition; changing color alone does not prove that EDI reached the target. |
A voluntary rating criterion is a separate check
The WELL circadian lighting feature illustrates the difference between an exposure recommendation and a project’s verification procedure. When a brief invokes a rating feature, identify the registered version, the spaces and users it covers, the reporting metric and measurement geometry, and any required time period or fraction of locations. A single seat that meets a melanopic EDI target does not establish compliance with a feature specified in equivalent melanopic lux (EML) or with a project-wide sampling requirement. Do not substitute one criterion for the other.
Before accepting a result, be able to name the point, direction, scene and spectrum used to measure it. If a report gives only horizontal lux and CCT, request the missing information before comparing it with an eye-level melanopic criterion.
An office brief calls for 250 lx melanopic EDI at the eye of an upright, seated person working at a monitor. What measurement is appropriate?
Horizontal photopic illuminance on the desk with no spectral data.
Scotopic illuminance directly below the luminaire.
Uplight incident on the ceiling.
Spectral measurement in the specified vertical eye plane facing the working view, then compute melanopic EDI.
At the same eye position and plane, electric lighting contributes photopic at a melanopic DER of 0.50 and daylight contributes photopic at a melanopic DER of 0.90. What is the combined melanopic EDI?
Two proposed tunable lighting scenes both read 4000 K on the controls screen. What would establish whether each meets an eye-level melanopic EDI requirement?
Confirm both screens display the same CCT; equal CCT implies equal melanopic EDI.
Compare rated luminaire power; the higher wattage scene necessarily meets the target.
Measure or model the spectrum and illuminance reaching the specified eye position in each scene, then compare the resulting EDI with the requirement.
Check only that each scene provides the same horizontal illuminance on the workplane.