6.3 Exterior Photometrics: Cutoff Classifications and BUG Ratings

Key Takeaways

  • Historical full cutoff required zero candela at or above horizontal and a separate high-angle intensity limit. U0 alone does not establish full cutoff.

  • BUG rates emitted lumens in angular zones. Backlight, Uplight, and Glare are evaluated independently.

  • Compare each applicable subzone against the applicable table. The subzone requiring the highest grade controls the category.

  • An upward change in aim can rotate light from below horizontal into the upper hemisphere. Recheck the installed orientation.

  • Check the adopted rule and actual site conditions, including boundaries, control schedules, and lighting zone.

Last updated: November 2026

Exterior lighting specifications must balance site visibility and safety against three environmental nuisances: sky glow (artificial brightening of the night sky from atmospheric scatter), light trespass (unwanted illuminance spilling across property boundaries), and glare (visual discomfort or disability veil in drivers and pedestrians). Use the legacy definitions to understand older documents, and IES TM-15 to read a zonal classification.

Legacy IES Cutoff Classifications

The historical ANSI/IESNA RP-8-00 classification sets limits on luminous intensity at high vertical angles. The normalization uses candela per 1,000 rated lamp lumens. It expresses an intensity limit, which is different from the percentage of luminaire flux emitted into a zone.

Legacy ClassificationAt or Above 90∘90^\circ (Horizontal)At or Above 80∘80^\circ (Glare Zone)Practical Implication
Full-Cutoff0 cd at all azimuths≤100 cd/1,000 lm\le 100\text{ cd}/1{,}000\text{ lm}Zero direct light at and above horizontal in the measured orientation
Cutoff≤25 cd/1,000 lm\le 25\text{ cd}/1{,}000\text{ lm}≤100 cd/1,000 lm\le 100\text{ cd}/1{,}000\text{ lm}Some direct light at and above horizontal is permitted
Semi-Cutoff≤50 cd/1,000 lm\le 50\text{ cd}/1{,}000\text{ lm}≤200 cd/1,000 lm\le 200\text{ cd}/1{,}000\text{ lm}Higher intensity is permitted at high angles
Non-CutoffNo upper-angle limitNo upper-angle limitUnshielded acorn globes and decorative post-tops

Why Legacy Cutoff Was Replaced

Legacy cutoff had two major blind spots. The denominator was rated lamp lumens, so the classification does not apply to the measured output of an integrated product tested with absolute photometry. The old scheme also lacked a separate backlight grade. For example, a full-cutoff fixture can direct light behind the pole into an apartment window below fixture height.


The IES TM-15 BUG Rating System

IES TM-15 (Luminaire Classification System for Outdoor Luminaires) assigns BUG grades using emitted lumens in specific solid angles. Output magnitude matters. Two luminaires may send the same share of light into a particular zone. If one emits ten times as many lumens overall, its lumen contribution in that zone is ten times as high.

Backlight evaluates rearward zones. Uplight evaluates emission in angular zones from horizontal up to zenith. The Glare grade uses selected angular zones, including high-angle output. Use the applicable distribution table because the Glare calculation can depend on luminaire symmetry. These are luminaire distributions. A grade is not a measurement of illuminance at a neighboring window or a calculation of a particular driver’s visibility.

For each category, find the lowest grade that meets all its limits. Suppose the low and medium backlight subzones first meet B1 but the remaining backlight subzone first meets B3. The resulting grade is B3. U0 requires zero lumens in the applicable uplight zones. Always verify the edition, mounting and front orientation, light output, and whether the submitted photometry includes the specified shield.

Aim, boundaries, and operating conditions

Suppose a forward ray is 85° from downward vertical in the plane of aim. Tipping the fixture upward by 15° in that plane rotates the ray to 100° from nadir, or 10° above horizontal. An aiming change can introduce uplight, but its effect depends on the measured photometric distribution. A rating for the original configuration does not carry over automatically. Verify the selected optics and aiming before ordering and check the installed angle at turnover.

Two luminaires with the same total lumens and U0 can differ in rearward or near-horizontal light. The historical full-cutoff class also limits high-angle candela. A U0 classification alone cannot verify either the legacy class or performance at the site.

The joint DarkSky/IES Model Lighting Ordinance illustrates lighting zones from no ambient lighting to high ambient lighting. Its descriptions start with LZ0, no ambient lighting desired, then LZ1 low, LZ2 moderate, LZ3 moderately high, and LZ4 high. Apply the local zone designation and the adopted rule, including the applicable exceptions and compliance method. Energy codes and voluntary rating systems can have their own applicability and tests.

For parking next to homes, mark nearby windows, site boundaries and typical views before selecting an optic. Compare an inward-facing candidate and a model with an approved house-side shield. Use the exact shielded report, mounting height, and aim to check boundary light, then confirm that coverage and uniformity on site still meet the brief. Verify any adopted spectrum, dimming, or curfew criteria separately.

References: Historical ANSI/IESNA RP-8-00, ANSI/IES RP-8-22 §2.6.3, IES TM-15-20, IES historical BUG addendum, and DarkSky lighting zones and the model ordinance.

Loading diagram...
Exterior Distribution Checks at the Installed Orientation
Test Your Knowledge

In the historical ANSI/IESNA classifications, how do full cutoff and cutoff differ at and above horizontal?

A

Full cutoff permits 50 cd per 1,000 lamp lumens.

B

Full cutoff requires zero candela. Cutoff permits up to 25 cd per 1,000 lamp lumens.

C

Both require zero candela and differ only in backlight.

D

The distinction is the lamp technology.

Test Your Knowledge

The low and medium backlight subzones first meet B1 limits. The remaining applicable backlight subzone first meets B3. What is the overall backlight grade?

A

B1

B

B2

C

B3

D

B0 if the uplight grade is U0

Test Your Knowledge

A beam edge lies 85° from nadir in its forward aiming plane. The installer tips the fixture up 15° in that plane. What happens to that edge?

A

It shifts to 100° from nadir, above horizontal. Recheck uplight in the installed orientation.

B

It shifts to 70° and remains below horizontal.

C

It shifts to 90° because horizontal is the largest possible angle.

D

The lighting zone changes automatically.