8.2 Architectural Daylighting Strategies and Glare Control
Key Takeaways
Higher apertures can bring light farther into the room. Useful depth depends on transmittance, geometry, surfaces and the task.
Roof apertures can reach areas remote from exterior walls. Test aperture spacing, direct sun and roof performance.
Choose exterior projections, interior shades and daylight redirection using the actual sun angles and views.
Verify the interaction among shading, electric lighting and user requests in representative scenes.
Sidelighting and toplighting
Sidelighting introduces daylight from exterior wall openings. Toplighting uses roof apertures to reach spaces away from walls. Both require a check of sky visibility, solar exposure and the tasks below or beside the openings. The location of the aperture is part of the lighting system, along with the glazing, shades and electric lighting controls.
| Sidelighting configuration | Design decision |
|---|---|
| Punched openings | Test the contrast between glazing and adjacent wall. Check several seated positions because the dark wall between windows can create a different view. |
| Ribbon glazing | Assess how much of the view includes bright sky and whether the perimeter task area has abrupt changes in illumination near mullions or obstructions. |
| Clerestory | Place the high aperture to serve the ceiling or deeper surfaces while managing direct sun. Verify ceiling reflectance and where occupants can see the aperture. |
An early layout may use aperture height to decide how far into the room to test. It cannot guarantee the depth of useful daylight. A deeply recessed window, shaded facade, dark ceiling or low-VT product can change the result. Evaluate the actual workplane and occupied view. If an office has a useful window view at eye level but a dark interior, compare a higher daylight aperture with changes to the ceiling and the electric-lighting zones.
| Toplighting system | Design decision |
|---|---|
| Horizontal or domed skylight | Check light-well depth, diffuser or baffle, beam patches and spacing. Compare uniformity in the occupied area. |
| Sawtooth or roof monitor | Use aperture orientation and geometry to control direct sun. Study times when sun can reach the glazing even if the principal design intent is diffuse light. |
| Tubular daylighting device | Study the collector, length and bends in the reflective tube, and the ceiling diffuser’s distribution. Use the tested assembly’s data. |
Skylight-to-roof ratio is aperture area divided by the applicable gross roof area. A 200 ft² skylight area on a 5,000 ft² roof is 4%. This is a description of the design. Before selecting the area, compare light distribution, solar gains and heat transfer, roof details, glazing performance and the adopted prescriptive or performance path. There is no project-independent threshold that optimizes all of these.
Shading, redirection, and the occupied view
A horizontal overhang can intercept high-angle sun. Low sun can reach beneath it, so test occupied periods for the specific facade. A vertical fin intercepts some oblique rays, depending on its depth, spacing and the sun’s azimuth. On an east- or west-facing classroom, model when the sun is nearly normal to the facade. Some fin arrangements provide little protection under that condition. Consider operable or exterior shading where the tested fixed geometry leaves objectionable sun exposure.
A light shelf can divide a view window from a high daylight aperture. A reflective shelf and ceiling can redirect daylight farther into the room. A shelf may also introduce bright reflected patches or reduce light on cloudy days. Compare versions with and without the shelf in several sky conditions. Results depend on the aperture and surface data.
For a roller shade, check both openness and visible transmission, as well as color, reflection, view clarity and the intended control behavior. A lighter reveal can reduce contrast around a bright window, especially with a matte finish. When occupants can see the sun or its bright reflection, address that condition directly with geometry or shading. Review the shades and electric lighting together. As a shade deploys, the light level at the sensor and at the task may change by different amounts.
Worked solar-noon projection
At N, a south-facing classroom has a window head 10 ft above the floor and sill 3 ft above the floor. A 3.5 ft horizontal overhang is flush with the head. Assume the overhang spans the window, the sun is directly in front, and there are no other obstructions. The vertical drop of the direct-beam shadow is .
- At summer solstice solar noon, . This exceeds the full 7 ft glass height.
- At winter solstice solar noon, . About 5.25 ft of the glass height, or 75%, is outside the overhang shadow.
The calculation covers direct beam at two instants. Between those instants, check profile angle and the overhang’s lateral extent. Include sky and ground reflections in a daylight model and evaluate both workplane contribution and views of the window. In a classroom, for example, compare the student seats, screen and teaching surfaces under shade states likely to occur during class.
References: DOE/LANL architectural daylighting, DOE envelope and daylight orientation, LBNL optical shelf research, LBNL monitored glare and redirection, and IES LM-83-23 shading and optical inputs.
Under the clear winter solar-noon geometry described in the worked example, how much of the 7 ft glass height is outside the overhang shadow?
1.75 ft.
5.25 ft.
7.00 ft.
11.77 ft.
People seated at monitors can see a bright segment of the afternoon sun through the west glazing. Which test best supports a shading choice?
Check only the average workplane illuminance at noon.
Select a dark finish around the window and assume the direct view is controlled.
Compare candidate shades at the occupied viewing directions and sun times, and check outward view and electric lighting response.
Select fabric by color alone to determine direct-sun transmission.
A large one-story concourse has useful daylight near its windows but inadequate daylight at the center. What should the designer do when considering a new roof aperture?
Compare candidate roof aperture layouts, their task-plane distribution, direct sun, and heat gains.
Specify a 4% skylight ratio for every concourse without calculation.
Count the code-defined perimeter daylight zone as the entire concourse.
Select the highest available solar heat gain coefficient to guarantee glare control.
Sections you finish are checked off in the contents.