Key Takeaways
The NCQLP LC examination is a 4-hour (240-minute), closed-book computer-based test administered by PSI at test centers; the 2026 window was October 12 through November 20.
The exam contains 200 multiple-choice questions: 180 scored items and 20 randomly distributed, unscored pretest items that candidates cannot distinguish from scored items.
Section 1 tests 100 to 120 stand-alone items across Existing Conditions (at least 25), Design Phase (at least 50), and Bidding and Construction Phase (at least 25).
Section 2 presents 16 to 20 project case studies of 5 questions each (80 to 100 items total) spanning Commercial, Institutional, Residential, Industrial, and Exterior occupancies.
Passing requires a scaled score of 70 on a 0-99 scale using form equating; use an approved basic or non-programmable scientific calculator that cannot store text, formulas, or data.
Why Exam Structure Matters for LC Candidates
The Lighting Certified (LC) credential, awarded by the National Council on Qualifications for the Lighting Professions (NCQLP), evaluates comprehensive competence across lighting design, engineering, application, energy codes, and construction delivery. Passing requires more than knowing photometry or fixture schedules in isolation: candidates must navigate a two-part examination blueprint within a strict time limit under standardized testing-center conditions.
Administration, Format, and Item Counts
The NCQLP LC exam is a 4-hour (240-minute), closed-book computer-based test (CBT) administered by PSI at physical testing centers by appointment. The published 2026 window was October 12 through November 20, 2026; check the next handbook for future dates. After NCQLP approves the application and PSI confirms eligibility to schedule, the candidate books a test-center appointment with PSI. No reference handbooks, code books, notes, or mobile devices are allowed inside the testing room.
Every exam form contains 200 four-option multiple-choice questions:
- 180 scored questions that determine whether the candidate meets the passing standard
- 20 unscored pretest questions distributed randomly throughout the test for statistical item calibration
You are not told which items are pretest. Treat all 200 items as if they count; there is no penalty for guessing.
The Two-Section Exam Blueprint
The exam divides into two structurally distinct sections that total 200 questions.
Section 1: Stand-Alone Questions (100 to 120 Questions)
Stand-alone items test discrete technical facts, code thresholds, calculations, and professional judgment across the three chronological phases of a lighting project:
- Existing Conditions ( questions): Field surveys, photometric and power measurements, existing luminaire and control audits, historic or code baselines, and owner/occupant needs assessments.
- Design Phase ( questions): Schematic design and design development, illuminance and luminance targets, lighting power density (LPD) compliance, source and luminaire selection, daylight integration, control intent, life safety, and construction documents.
- Bidding and Construction Phase ( questions): Bid evaluation, value engineering, submittal and shop-drawing review, requests for information (RFIs), commissioning, luminaire aiming and focusing, and project closeout.
Notice that the three phase minimums sum to items. Depending on the specific exam form, up to 20 additional stand-alone items may appear across these phases.
Section 2: Case Studies (16 to 20 Case Studies, 80 to 100 Questions)
Section 2 embeds technical decisions inside realistic multi-disciplinary project scenarios. Each case study has a shared project brief and 5 multiple-choice questions. A brief may include a plan, schedule or control sequence; use only the details provided. The case count corresponds to to questions total. Minimum case-study counts are enforced across five occupancy categories:
| Blueprint Division | Item Volume | Minimum Distribution Breakdown |
|---|---|---|
| Section 1: Stand-Alone Items | 100–120 questions | Existing Conditions ; Design Phase ; Bidding & Construction |
| Section 2: Commercial Case Studies | case studies ( Qs) | Office, retail, hospitality/entertainment, sports/recreation |
| Section 2: Institutional Case Studies | case studies ( Qs) | Education, health care, transportation, museum, worship, libraries, government/correctional |
| Section 2: Residential Case Studies | case study ( Qs) | Single-family, multi-family, assisted living |
| Section 2: Industrial Case Studies | case studies ( Qs) | Manufacturing, warehouse |
| Section 2: Exterior Case Studies | case studies ( Qs) | Site lighting, roadway lighting |
Together, the Section 2 occupancy minimums total case studies (80 questions), leaving up to 4 additional case studies (20 questions) depending on the form's exact split with Section 1.
Scoring, Form Equating, and Reporting
Candidates must earn a scaled score of 70 on a 0–99 scale to pass. NCQLP establishes the raw cut score through psychometric form equating, which adjusts the raw number of correct answers needed so that slightly harder and slightly easier exam forms represent an identical standard of competence. Consequently, a fixed raw passing percentage is not published.
Warning
Common Exam Trap: Do not mistake a scaled score of 70 for 70% raw accuracy ( questions). Use timed practice to identify weak topics, not to predict an official scaled score.
Candidates receive a pass/fail notification immediately after testing, with a detailed score report to follow by email. The handbook does not specify the email delivery interval.
Calculator Policy and Applied Computation
PSI enforces strict calculator rules at check-in:
- Permitted calculators: Basic handheld battery- or solar-powered models without paper tape or alphabetic memory. Scientific models must be non-programmable and must not have a full A–Z keypad or store text, formulas, or data. The handbook lists the HP 12C and TI BA II Plus as examples of permitted financial calculators; test-center staff inspect devices.
- Prohibited devices: Programmable, graphing, printing, and alphabetic-keypad calculators and phones. If a scientific calculator cannot meet the handbook criteria, bring a basic model instead.
Choosing a non-graphing scientific calculator (rather than a bare four-function desk unit) pays immediate dividends on trigonometric photometry problems. For example, suppose a Design Phase question asks for horizontal illuminance at a point on a horizontal workplane below a luminaire approximated as a point source. In the vertical plane toward that point, its intensity is at from nadir. Since the slant distance is and the plane is horizontal, the distance and incidence terms yield:
Using a scientific calculator, and . Substituting the values gives:
Use degree mode, and do not insert the slant distance into the cosine-cubed form: that form already accounts for it. See the CIE photometric distance law and the 2026 NCQLP Candidate Handbook (pp. 1–6).
A candidate sits for the NCQLP LC examination and wonders which items affect their official score. How are the 200 multiple-choice questions scored?
All 200 questions are scored equally, and 140 correct answers guarantees a scaled score of 70.
180 questions are scored and 20 randomly placed pretest questions are unscored; a scaled score of 70 on a 0-99 scale is required via form equating.
Section 1 stand-alone questions count for 40% of the score and Section 2 case-study questions count for 60%, with a fixed 70% raw cut score.
Only the 160 minimum mandatory items across Sections 1 and 2 are scored, while the remaining 40 items serve as tiebreakers.
Which calculator is permitted for use inside a PSI testing center during the NCQLP LC exam?
A graphing calculator with its memory cleared by the proctor
A smartphone running an approved scientific calculator app in airplane mode
A programmable calculator featuring a full QWERTY alphabetic keyboard
A basic solar-powered handheld calculator with no paper tape, text memory, or alphabetic keypad
In Section 2 of the NCQLP LC exam, which two occupancy categories together carry the highest minimum number of required case studies?
Institutional (6 or more case studies) and Commercial (5 or more case studies)
Commercial (5 or more case studies) and Industrial (4 or more case studies)
Institutional (6 or more case studies) and Exteriors (4 or more case studies)
Design Phase (50 or more questions) and Existing Conditions (25 or more questions)
Sections you finish are checked off in the contents.