8.1 Daylight Availability, Sky Conditions, and Glazing Metrics
Key Takeaways
Solar altitude is measured above the horizon. Azimuth and facade orientation affect when a window sees direct sun.
The CIE Standard Overcast Sky varies by elevation. At the zenith its luminance is three times the horizon value.
Visible transmittance, solar heat gain coefficient, and U-factor answer different design questions.
Compare the exact glazing assembly and state. Confirm daylight distribution, glare, and seasonal thermal performance separately.
Read the sun position first
Solar altitude is the angle of the sun above the horizon. Solar azimuth describes its direction along the horizon. Check the convention used by the tool before interpreting the reported azimuth, such as degrees clockwise from true north. Local solar noon occurs when the sun crosses the local meridian. Its civil clock time varies with date, longitude and time-zone rules.
For an unobstructed geometric approximation at solar noon, with latitude and signed solar declination :
At latitude N, with declinations rounded to , , and , noon altitudes are , and . At this latitude the noon sun is due south. In regions between the tropics its direction at noon can change with the season. Actual obstructions and site coordinates matter for shading.
| Facade near 40° N | What to check |
|---|---|
| South | Midday summer sun is higher than winter sun. A projection can shade selected high-angle rays while admitting lower-angle rays. |
| North | Diffuse skylight can dominate. Check early and late summer sun and any bright exterior reflections. |
| East | Low morning sun can enter at occupied hours before an overhead projection intercepts it. |
| West | Low afternoon sun can reach deep into the space and create uncomfortable views. Check whether solar gains coincide with cooling demand for that site. |
Choose the sky representation
The CIE Standard Overcast Sky is symmetric in azimuth and contains no direct sun. Luminance at elevation is , where is zenith luminance. The horizon is at . At elevation the value is . A window’s view of that sky can still differ depending on its geometry, surrounding buildings, or reflections.
CIE general sky distributions include clear and overcast conditions. A clear sky’s diffuse luminance varies with sky direction and the sun’s location. Include the direct-beam component where the selected method calls for it. Annual climate-based daylight modeling commonly uses a Perez sky model with hourly data such as direct normal and diffuse horizontal irradiance from a typical meteorological year. Use the weather file for the site and document the time convention, geometry and glare-control settings.
Read the whole-window data
| Metric | What it expresses | What to verify |
|---|---|---|
| Visible transmittance (VT) | Fraction of incident visible light transmitted, with photopic weighting under the rating conditions | Use comparable whole-product or center-of-glass data consistently. Frame and sash affect whole-product ratings. |
| Solar heat gain coefficient (SHGC) | Fraction of incident solar energy admitted as direct transmission or inward-flowing absorbed heat | Check the complete product and the shading or tint state. |
| U-factor | Heat transfer rate per unit area per unit temperature difference under rated conditions | Lower U-factor reduces heat transfer for a given area and temperature difference. Compare the stated units and assembly. |
| Light-to-solar-gain ratio (LSG) | for the stated assembly and state | Compare VT and SHGC individually as well. The ratio alone tells you neither absolute quantity. |
The window-to-wall ratio divides the applicable fenestration area by gross wall area under the stated counting convention. If a facade has 120 ft² of fenestration in 480 ft² of gross wall, the ratio is 25%. That describes the geometry. To decide whether it works, compare views, location of the glazing, glare response, the applicable code limits and seasonal heat transfer.
Ceramic frit changes direct and diffuse transmission according to its actual pattern and glass assembly. Use measured data when modeling its optical effect. Electrochromic glazing can change tint, which changes VT and SHGC. Verify the actual range, switching time, control sequence and low-sun conditions. A field result from one installation with a deep canopy does not establish glare control at an unshaded site.
Worked comparison of glazing
Consider two complete products in a 120 ft² bay, about 11.15 m². Product A has VT 0.44 and SHGC 0.40. Product B has VT 0.66 and SHGC 0.28. Their light-to-solar-gain ratios are and .
For an illustrative uniform incident irradiance of 650 W/m², if the rated SHGC values apply, the estimated heat gains are and . The difference is about 870 W, or 30% of the modeled solar gain through A. Under comparable incidence, B’s rated ratio of transmitted visible light to A’s is . Neither comparison supplies the desk illuminance or the change in annual cooling energy. Model reflections, angular transmission, external shading, climate, equipment and controls for those questions.
References: NOAA solar geometry, CIE Standard Overcast Sky, Lighting Analysts Perez model implementation, NFRC rating label, DOE window performance data, UC Davis CLTC daylighting guide, and LBNL electrochromic field study.
What describes the CIE Standard Overcast Sky?
Equal luminance at every elevation.
A directional peak immediately around the sun.
A sky symmetric in azimuth with three times as much luminance at the zenith as at the horizon.
A weather file used to estimate the azimuth of the sun.
Which glazing option has the highest light-to-solar-gain ratio on the same rating basis?
VT 0.64, SHGC 0.28.
VT 0.42, SHGC 0.28.
VT 0.78, SHGC 0.70.
VT 0.30, SHGC 0.36.
A west-facing office experiences uncomfortable direct sun late in the afternoon. Why should the designer check the sun path before sizing a horizontal overhang?
Turning a glazing product west increases its rated U-factor.
Diffuse zenith skylight sets the shadow from direct sunlight.
The rated visible transmittance determines the length of all shadows.
Low-altitude rays can pass under the projection and penetrate into the space.
Sections you finish are checked off in the contents.